ARTIS pheno VE20 Touchscreen Overview Video
This video introduces the touchscreen on your ARTIS pheno VE20.
Welcome to the Artis Fino touchscreen introduction video. This video will introduce you to the basic functions of the touchscreen. The settings menu is located in the top right corner of the touch screen menu. Here you can change the selected procedure, change the patient position, select the image, flip and close the patient. In the examination menu you can change the fluoro and acquisition protocol and adjust parameters such as frame rate, pulse rate and scene length. Additionally, you can access the 3D wizard in the examination menu. In the display menu you can change the exam room display layout and change the input source of the segment in the layout. In the see arm position menu you can select pre programmed system positions. In the table menu you can access functions related to the table. You can adjust the table height and Additionally table tilt, table cradle and table transversal. An lanja tude Inal movements in the detector menu. You can access functions related to the detector, including detector rotation and lift, zoom and switching the laser light on and off. In the road map and overlay menu you can activate the functions road map and overlay reference image. Case flow allows you to assign specific references of a user to a procedure. After you select case flow, the following settings can be automatically applied. X Ray and imaging parameters, exam room display layout. See Arm start position, table position, collimation, zoom size. Overlay and road map state. Your favorite settings and functions can be added to a favourites list for easy access. To open a menu, press on the menu item on the touch screen. Move your finger up and down the menu to scroll through the menu items. To edit the position of the items in the menu or to add menu items to the favourites, perform along touch on the touch screen. To add an item to the favourites menu, press on the Star next to the item. To exit editing mode, press the check mark at the top right of the menu. To return to the main menu, press the arrow at the top left of the touch screen. To edit the favourites, open the menu. Perform along touch on the touch screen to enter Edit Mode. To change the position of a menu item, press on the left side of the item and move it to a new position with your finger. To remove an item from the favorite menu, press on the cross on the menu item. To change the frame rate and the fluoroscopy dose, select the examination menu. For example, to change the fluoroscopy protocol, select the fluoroscopy protocol. To move the system to a pre program position, select the see arm position menu. Select the desired position. Hold to drive appears, press hold to drive to activate the movement. The system will move into position. Keep pressing, hold to drive until the system reaches the position. To change to another position list, select the arrow at the top right of the touch screen menu. The menu of position lists opens. Select the desired position list. You can access the direct positions menu anytime by swiping from right to left on the touch screen. The direct access bar is at the bottom of the touch screen. Here you can access your most frequently used functions.
@ Siemens Healthcare GmbH, 2020 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be Touch used as training material only and shall by no means substitute the Operator Manual. Any material used in Fluoro Protocol this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. card 1 The Operator Manual shall be used as your main reference, in particular for relevant safety information Fluoro Protocol like warnings and cautions. Favorites protocol ARTIS Examination Dirrect Positions2 Direct Positions2 Editing Mode FL card 1 Cancel Auto Drive System positions FL(-) Card 1 FLO) card 1 Switch Card / Angio Note: Some functions shown in this material are optional and might not be part of your system. The Acquisition Fluoro Sets I . fluoro triplet card 1 15f/s Stop O •Position Stop O-position Display The reproduction, transmission or distribution of this training or its contents is not permitted without FL Card 1 information in this material contains general technical descriptions of specifications and options as well 15f/s Fluoro Define Frame Rate Patient Transfer Anatom. positions FL coro ccM Series Descr. < Default> Define as Define as ROI as standard and optional features that do not always have to be present in individual cases. express written authority. Offenders will be liable for damages. card 1 d Side Pulse Rate FL Card 1 Head Side Direct ions 7.5 pls Certain products, product related claims or functionalities described in the material (hereinafter collectively All names and data of patients, parameters and configuration dependent designations are fictional ROMP overlay ROMP Acquisition Fluoro Direct Positions2 Current Positions 1. CARD pr„. FL Card 1 "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, and examples only. Hold to Drive the future availability of said Functionalities in any specific country is not guaranteed. Please contact your Pulse Rate 15f/s Frame Rate All rights, including rights created by patent grant or registration of a utility model or design, are reserved. local Siemens Healthineers sales representative for the most current information. Series Descr. Series < Default> Measure Field
- artis
- pheno
- ve20 artispheno
- atris
- robotic
- c-arm
- angio
- angiography
- interventional
- surgery
- radiology
- touchscreen
- caseflow