Artis Systems VD11: System Basic Handling - Postprocessing Job Aid
Artis Systems VD11: System Basic Handling - Postprocessing Job Aid
SIEMENS Healthineers System Basic Handling Postprocessing Artis zee, Artis zeego, Artis Q, Artis Q.zen VD11 Version 2019.07 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: Job Aid 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 Unrestricted System Basic Handling Postprocessing – SIEMENS Healthineers Table of Contents Postprocessing task card 3 Image postprocessing - Touchscreen 9 DSA postprocessing - Touchscreen 10 Default review mode 11 Patient data correction 12 Rearrange series/scenes/images 13 Patient data correction 14 Patient search 15 Archiving/Export/Transfer Data 16 Configuring automatic deletion 19 2 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Postprocessing Taskcard 13.10.21-12:49:33-DST AX R-D TC KO15B 3 13.10.21-12:49:33-DST-81994 Image area ISKO24A 1/1/1800 AXIOM-Artis VA10A 131015 STUDY 1 2 10/21/2013 Control area 12 50:07 PM 4 39/282 PostProo 3 Patient information area 4 Review controls 5 Subtask cards R 5 6 Quick access area 7 Status area with system messages and status icons FL(-) CTO 1580 x 1424 EE 4% 6 cm 39 DDO 50% 49 MA 14 WC 2037 WW 2700 7 1 2 3 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Postprocessing Task Card 3 Patient information area 4 Review Controls Click the patient information area yellow Scene Directory: Call up an overview display of the stored folder with the right mouse button to scenes/images/reference images. change the patient position. Filter to the scene directory: Scene: only scenes (multiframes): acquisitions and fluoroscopy Scene 01.05.21-11:37:51-DS. Scene Head First - Supine Ref. Image: only reference images Ref. Image Head First - Prone Store Monitor: only stored images Store Monitor + Ref. Image Head First - Left Lateral + Ref. Image: scenes and reference images + Store Monitor Head First - Right Lateral SM + Ref. Image Feet First - Supine + Store Monitor: scenes and stored images (no reference images) Feet First - Prone Feet First - Left Lateral SM + Ref. Image: stored images and reference images Feet First - Right Lateral Stand and Table Scene - / Scene + Ref - / Ref + Changing the review frame rate: Starting/ Stopping the Loop DR 10 f/s 10 f/s A running scene is stopped at the last frame displayed and switched backward or forward by one frame. 4 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Postprocessing Task Card 5 Subtask Cards View Image DSA Full-screen View Image DSA R Flip Horizontally Scene Overview (4X4 View) R Flip Vertically 20 Shutter CLEARstent opac Invert Gray Scale Subtask card Image Subtask card View Opacification lopac 000 Zooming/Panning Zoom to Acquisition Size Looping through All Scenes 5 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Postprocessing Task Card 5 Subtask Cards View Image DSA + Move Mask Averaging + MI Native/Substracted Zooming/Panning MI Of Anatomical Background Zoom to Acquisition Size Jopac Subtask card DSA Pixelshift Opacification opac Invert Gray Scale 6 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Postprocessing Task Card 5 Subtask Cards Adjust| Calib. Tools 2100 Windowing Adjust Calib. Tools Auto ISO Calibration: Isocenter 1695 2250 Set “brightness” & “contrast” calibration is automatically auto 2400 D'- preselected by the system for auto auto auto image angle 50° ... 130°. Auto Window auto Auto TOD Calibration: TOD calibration is automatically M. 20 Window Home auto preselected by the system for image angle 0° ... 50° or 130° ... 180°. Subtask card Adjust 21 Edge Enhancement Subtask card Calibration Manual Distance Calibration: Edge Enhancement Home After drawing the distance line by moving and marking with the mouse pointer, the length of the distance line is entered and calibration is applied. 7 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Postprocessing Task Card 5 Subtask Cards Adjust Calibr. Tools XYZ Annotation: Enter text Drawing Line ......................... in the image XYZ ............................... ................................. Drawing Circle Pointer: point out certain image detail on the screen Drawing Polygon Distance: The distance between two points of a straight distance line or along a curve. Subtask card - Tools Hide Annotations and Angle: Angle measurement by drawing two lines Measurements Drawing Arrow 8 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Image Postprocessing - Touchscreen Settings Exam Image Quant 4D ? Inverting grayscale values ID Scroll to next frame of the scene View ×2 1:1 ×2 Zoom by a factor of 2 Scroll to previous frame of the scene SM Adjust n Zoom to Acquisition Size (1:1 pixel Scroll to next scene REF Applications DSA 1:1 K ? display) + REF Scroll to previous scene Tools Windowing AS 14 n Edge Enhancement Open scene directory Example of Image task card Generating and storing a Measurements CLEARstent image XYZ Annotations and graphics 9 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers DSA Postprocessing - Touchscreen DSA Anatomical Background Anatomical Background Pixel Shift ? Move Region of Interest with joystick. + Move Mask Q r Replace Mask Confirm correct position with joystick button. Display Scene Display Scene Native Native DIT Auto × auto 1 Pixel Shift 1. Pixel Shift IN Manual SM Opacification Opacification JJopac JJopac TON Flexible REF Move Mask set Replace Mask set 10 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Default Review Mode View Image Options Help Default Review Mode ? X Zoom Defining the default review mode* Acquisition Size Unstored Fluoro / RDMP Loop 1. In the Postprocessing main menu, select View > Review Mode. Shutter Stored Fluoro / RDMP Loop A dialog box appears with the available review modes. ¥ Annotation CARD Loop 2. Select the required review mode for the available acquisition modes. Image Text DR / DSA Loop 3. Confirm your selection by clicking Close. ¥ Scene Timer ECG Display PERI Loop Any current scene will immediately be reviewed with the mode Loop All Scenes 3D / DYNA Toggle selected for the scene type. Review Mode. Any new scenes loaded for review are replayed with the modes you Hide Patient Information Close Help have set. * Option with Fluoro loop license 11 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Patient Data Correction Correc X Open the Correct window: '06.07.27-08:50:26-DST" on 'Local" 1 Senes selected 1. Select Edit > Correct in the main menu of the PostProc task card. Modifier's Name meduser or – Alle 48 07 27-08 50 28-DST First name – Modifier's name meduser Patient ID 06.07.27-08:50:26-DST37999 Middle name Patient ▪ Call up the Patient Browser. Title Suffix ▪ Select the patient entry, the study/series/scene. Referring physician Other Patients name(s) Admission D Other Patient ID(s) Hospital ▪ Select Edit > Correct in the menu of the Patient Browser. Ethnic group Military rank 2. The Correct window is displayed. Accession No Date of birth 1/1/1900 Study D Sex . Male . Other Study . Female · Not set 3. Enter the correct patient data. Height in Series description CARD_SUB Weight Ibs oz Metric 4. Enter the modifier`s name: After the patient data is corrected, enter your Series date 7/27/2011 Address Series name under Modifier's name or select your name from the selection list Number Additional info and click OK. Comment Instance OK Cance Help 12 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Rearrange Series/Scenes/Images 1. Call up the Patient Browser. Rearrange X "03.01.03-10:10:24-STD" on "Local" 2. Select the series/scenes (images). 1 Series (total 0 Images, 0 NonImages, 0 Waveforms 3. Drag and drop: Drag the selected data to the target position and release the mouse ) will be moved to button. Patient 02.12.20-12:58:29-STD Study or- - Modifier's name Cut and paste: Click this icon or call up Edit > Cut in the menu of the Patient Browser. OK Cancel Help Click the target position. Click this icon or call up Edit > Paste in the menu of the Patient Browser. The Rearrange dialog box will be displayed. 4. Enter your name under Modifier's name or select your name from the list. Rearrangement is not possible in the following 5. Confirm by clicking OK. cases: ! Caution Rearranged to the wrong data level − Scenes/images rearranged to a series acquired − ▪ Wrong diagnosis caused by wrong image information. Patient orientation and laterality information may be wrong. with another patient position ▪ When images were acquired on a different − ▪ References may be lost. modality (e.g. CT) 13 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Patient Data Correction Renaming/correcting patient data: ▪ After opening the correct window, click the Patient subtask card. ▪ Enter the correct patient data. If necessary, change other data. Changing the registered patient position after acquisition: ▪ After opening the correct window, click the Series subtask card. ▪ Select the correct position from the Patient position selection list. It is not possible to correct or rearrange patient data in the following cases: Specific data of special objects, e.g. patient position in the Exam Protocol SR − Protected data − Data of HIS/RIS patients − Data of the current examination patient during radiation − Data on external media − 14 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Patient Search Patient Search Using the Patient Search, you can query and retrieve . Basic Search Patient Name From Nada patient and examination data from workstations and long- Patient ID Study Date Date of Birth Study Time term archives that work with other DICOM program Sex Any Accession Number Modality systems. Advanced Search Study Description From To Click this icon in the toolbar. Study ID PPS Start Date Referring Physician PPS Start Time or – Reporting Physician Body Part Exam – Study Instance UID Performing Physician Select Patient > Search... in the menu of the Patient Series Instance UID Request Procedure D Series Number Scheduled Procedure DD Browser. Series Description Approval Status The Patient Search window is displayed. Reporting Search Search Clear ▪ Enter your search criteria and click Search. Import Import Job Status Image List Discard search results on close Close Help No node available 15 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Archiving/Export/Transfer Data Archiving to & Send to 1. Setting a directory filter 2. Displaying the scene directory 3. Archiving/Sending Pick the required display In PostProc or Quant task card: Click this icon. Click this icon in the Patient from the selection list. The system switches to 4 x 4 display mode and displays Browser. the representative image of each stored scene. – Scene or – - + To select all objects: Select Transfer > Send To... or Select Image > Select All in the main menu. Scene Transfer > Archive To... in the Scene or – main menu. – Ref. Image Store Monitor Press Ctrl + A. + Ref. Image + Store Monitor Click the first object. Press the Shift key. Scroll to the You will see this icon at the SM + Ref. Image All last object and click it. bottom of the control area. To select a series of objects: Data is being sent. Click the first object. Press the Ctrl key and click additional objects. 16 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Archiving/Export/Transfer Data Exporting scenes/images Export Image AS ... ? X Format 1. Select Image > Export Image As... in the main menu of the PostProc task card. Format Type AVI Type AVI The Export Image As window appears. AVI Range Bitmap From 33 To 44 Select All 2. Select the desired format from the Type selection list. JPEG Settings 3. Select the range (if applicable). Full Frames (Uncompressed) Change Image Options Help Output Size: 1024 × 1024 Plane: A+B 4. Select planes (if applicable). Invert Gray Scale Include: M Text M Graphics DECO 5. Set the image matrix. Native Path And File Name 6. With or without text/graphics/ECG Max Fill Override HACDR_OFFLINE ICStent AX_Angio_(S3_11_F33-44)A.avi 7. Define the file name and the export location. AX_Angio_(S3_12_F33-44)B.avi Flip Horizontally 8. Start the export by clicking OK. Flip Vertically Export Progress: Export Image As ... Record Off-line Files Send To 3D ... OK Cancel Help 17 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Archiving/Export/Transfer Data Auto transfer Completed ~ & Don't care Images to ARTISSRV1 Always select "Don't care", otherwise transfer rules will not work! Exporting to CD-R/DVD 1. Insert an (empty) CD-R/DVD into the writer. The first time you export data to a new medium, the Enter Label dialog box is displayed. Enter a unique name for the medium. 2. Click this icon in the Patient Browser. or – – Select Transfer > Export To... in the main menu. A dialog box with the available archiving destinations appears. 3. Select one or more destinations and click Export/Archive. The image data will be archived at the selected destinations. 18 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Postprocessing - SIEMENS Healthineers Configuring Automatic Deletion AutoDelete Configuration X 1. Select Options > Configuration... in the main menu. Local RawData Recycle Bin Automatic deletion is performed at following timepoints for following data 2. Double-click the Auto Delete icon. The Auto Delete Configuration window is displayed. Deletion can also be started manually via the menu (Edit > Auto Delete) Select whether Recycle Bin should be used or not: Click the Do not permanently Do not permanently delete data. Move data to recyclebin − delete data. Move data to recycle bin check box to change the setting. 3. Select the database (Local Database or Recycle Bin) for which automatic deletion will be Timepoints for deletion % configured. If database fillstate has reached 80 or 4. Define the Timepoints for deletion. 8:00 Monthly O Day Select the options to be used. of every month(s) − 5. Define the Data to be deleted. Series that contain certain flags (only for Local database) O The Sunday of every nonth(s) Data to be deleted Data that is older than specified Delete all series with following flags Select the rules to be used. [ Archived − [ Archived + Committed Sent 6. Configure the option Ask confirmation before deletion. Sent + Committed or If this option is selected, users are prompted when Auto Delete starts to confirm Delete all studies which are older than 14 − day(s) whether data should be deleted. Ask confirmation before deletion 7. Click OK to make the settings take effect. OK Cancel Help 19 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 20 Effective Date: 07/28/2020|HOOD05162003109257 Unrestricted © Siemens Healthineers, 2019
- post processing
- ARTIS
- zee
- Q