Artis Systems VD11 System Basic Handling - Examination Workflow Job Aid
Artis Systems VD11 System Basic Handling - Examination Workflow Job Aid
SIEMENS Healthineers System Basic Handling Examination Workflow Artis zee, Artis zeego, Artis Q, Artis Q.zen VD11 Version 2019.07 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: Job Aid 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019 Unrestricted System Basic Handling Examination Workflow – SIEMENS Healthineers Table of Contents Patient Registration 3 Touchscreen – Control Console 6 Touchscreen – Settings 7 Touchscreen – Exam 8 2 Effective Date: 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Examination Workflow – SIEMENS Healthineers Patient Registration Register an emergency patient 1. 1. Select Patient > Emergency... in the main menu or in the + menu of the Patient Browser. The Emergency Registration window is displayed. or – – + Press the Patient Registration (Num 0) key on the symbol keypad. The Patient Registration window opens. ➢ Click the Emergency button. 2. The system automatically creates default entries for the mandatory fields. 3. Select the Patient position from the list. (Not required Patient Registration (Num 0) key for cardiac examinations) Confirmation X 4. Confirm the patient position before start. Patient position Head First - Supine Confirm Cancel Help 3 Effective Date: 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Examination Workflow – SIEMENS Healthineers Patient Registration Register patient manually Patient Registration X PROCEDURE PATIENT 1. Press the Patient Registration (Num 0) key on the symbol Last name Accession No First name Request ID keypad. Middle name Requested L ...... Title Suffix procedure(s) Other patient name(s) or – Other patient ID(s) Study – Ethnic group Study comment Select Patient > Register... in the main menu. Military rank Patient ID Date of birth [M/d/yyyy] Patient position Head First - Supine or – – Sex Male Female Other INSTITUTION Age Years Open the Patient Browser. Institution name Testcenter Forchheim Height in Weight Ibs oz Metric 1. Performing physician VC20A_110809 Click this icon, and the Patient Registration window opens. Address 2. Performing physician Dr. Testautomation 2. Enter the data (data shown in boldface type are Additional info 1. Operator 2. Operator mandatory entries). Details HOSPITAL ➢ Select the required exam program from the Study list. Referring physician Requesting physician ➢ Select the Patient position from the list. (Not required for Admitting diagnosis Ward Admission ID cardiac examinations) Preregister Exam Searc Cancel Patient Group Emergency Help ➢ Click Exam. Patient Registration ISO_IR 100 3. Confirm the Patient position before start. Mandatory fields in bold. Fill the height and weight to get the maximum skin dose in exam protocol. 4 Effective Date: 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Examination Workflow – SIEMENS Healthineers Patient Registration Register patient from the RIS 1. Open the Patient Browser. 2. Double-click the the scheduler icon to update it and then open it. or – – Select View > Update Worklist in the menu of the Patient Browser. Local Database 3. Double-click the patient to be examined. The Patient Registration window opens. Scheduler 4. Add any required data. CD_DVD_COMBO 5. Select the Patient position from the list. DVD-ROM_IVS 6. Click Exam. 7. Confirm the Patient position before start. 5 Effective Date: 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Examination Workflow – SIEMENS Healthineers Touchscreen Control Console Middle mouse joystick button: 2 Store a 2D reference image when assigned to 2D postprocessing – Windowing button when assigned to 3D postprocessing – ? Left mouse joystick button: 4 Right mouse joystick button: 3 Select and manipulate objects. Finish steps or exit functions. – TO 5 Menu button when no function is active – 1 Touchscreen 6 Open the Onscreen menu. 2 Mouse joystick 4 Mouse joystick 3 Keys for Onscreen menu 5 Open the Onscreen menu 6 Open the layout gallery 6 Effective Date: 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Examination Workflow – SIEMENS Healthineers Touchscreen - Settings Settings Exam HFS Image Quant 4D ? FFS Touch Screen Layout Name Checking/changing the patient position Layout HFDR FFDR SM RDMP / DSA LIVE REF HFS: Head First - Supine FFS: Feet First - Supine Assist Screen HFS REF Patient Close Patient HFDR: Head First - Right Lateral FFDR: Feet First - Right Lateral HFDL FFDL REF HFDL: Head First - Left Lateral FFDL: Feet First - Left Lateral AS HFP FFP HFP: Head First - Prone FFP: Feet First - Prone LIVE REF Selecting the display mode as an unsubtracted live fluoroscopy image or a selected reference image on Assist Screen during Roadmap / DSA. Note: For biplane scenes, the display mode is always the same in both planes. 7 Effective Date: 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Examination Workflow – SIEMENS Healthineers Touchscreen - Exam Settings Exam Quant 4D ? Store fluoroscopic scene Block radiation Exam Set A SM Store Monitor Block unit movements KA KV SM Fluoro Prog. Acq. Prog. Select Large Display Layout REF 15 p/s 3 f/s Dilatation timer REF Store reference image REF Toggle the active screen DSA REFOS REF AS RDMP RDMP B +al AS A black and white frame identifies the active reference screen Open the Image Player A Select the acquisition plane(s) Classic Roadmap TO DSA Roadmap REFPS Overlay Reference Image RDMP DSA RDMP B 8 Effective Date: 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Examination Workflow – SIEMENS Healthineers Touchscreen - Exam A selection of available exam sets and Display the available KON Change the assigned acquisition programs Acq. Prog. acquisition programs Fluoro Prog. fluoroscopy/roadmap program Exam Set Selection More Exam X Settings Exam Image Quant ? Settings Exam Sets ... Image Quant ? CARD CARD 30 Coro 3040 CARD HDR 15 f/s DSA Special Coro Coro CARE Coro CARE Coro 2020 15 f/s 15 f/s minus 10 f/s 15 f/S LV 3040 CARD SM FL 3040 15 f/s 18 SM FL - Angio 7.5 p/s DSA 7.5 LV 15 f/ LV Care LV 2020 15 f/S 15 f/s Coro 3040 Log CARD 3040 REF 15 15 f/s REF FL Angio 7.5 p/s Toggle the active screen 2 f/s ClearStent ClearStent live VFR time LD ClearStent live VFR time VFR time ClearStent A black and white frame CARD CTO REF VFR time FL+ Angio AS RDMP 10 p/s identifies the active reference v V screen [P16_Card_LD 3 f/s Display all available frame 15 p/s Display all available pulse rates rates 9 Effective Date: 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers 10 Effective Date: 07/28/2020| HOOD05162003109230 Unrestricted © Siemens Healthineers, 2019
- Examination
- zee
- ARTIS
- Q
- Q.zen
- zeego