Artis Systems VD11 System Basic Handling - Safety Job Aid
Artis Systems VD11 System Basic Handling - Safety Job Aid
SIEMENS Healthineers System Basic Handling Safety Artis zee, Artis zeego, Artis Q, Artis Q.zen VD11 Version 2019.07 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: Job Aid 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 Unrestricted System Basic Handling Safety – SIEMENS Healthineers Table of Contents Emergency STOP buttons 3 Warning Signs 4 Reset unit computer/Collision Override 5 Patient rescue during power failure: Ceiling 6 Patient rescue during power failure: Multipurpose 7 Patient rescue during power failure: Artis zeego 8 Brake test – Artis zeego 10 2 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Safety – SIEMENS Healthineers Emergency STOP Buttons STOP In the case of danger, press one of the STOP STOP STOP red emergency STOP buttons STOP immediately. On the front sides of the Artis zee stand control module On the front sides of the Artis zee multi-purpose and table control module table control module and stand control module • All system drives are shut down and movements are stopped immediately. • Radiation is interrupted, fluoroscopy and acquisition are stopped. However, radiation can be released CTOP STOP STOP again if you press the fluoroscopy/exposure release pedal On the front sides of the Artis zeego stand control modules On the Artis zee multi-purpose patient table again, even without canceling STOP. and table control module support arm 3 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Safety – SIEMENS Healthineers Warning Signs Do not look directly into the light beam for a lengthy time. HAZARD LEVEL 1M LASER RADIATION DO NOT VIEW DIRECTLY WITH NON-ATTENUATING OPTICAL INSTRUMENTS Avoid directing the beam toward the eyes of a trauma or anesthesia patient. Danger of crushing the patient and/or operator. Maximum patient load, without accessory load and without CPR load. max ... kg (CPR = Cardio-Pulmonary Resuscitation) Maximum patient table load .a. kg (patient load + accessory load - without CPR load) 4 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Safety – SIEMENS Healthineers Reset Unit Computer/Collision Override Stand Control Unit Reset 1. Simultaneously press and hold the direct position buttons I and II and also push the STOP emergency STOP button on the stand/C-arm control module. Wait until the bypass screen appears on the Exam room monitor. 2. Then pull the emergency STOP button and after that release the direct position buttons I and II. Collision Override CAUTION O If a collision has occurred and the collision sensor has responded: 1. You can initiate a movement by pressing and holding Higher risk of collision. the direct position buttons I and II simultaneously. The Risk of mechanical message "Collision control deactivated" appears. damage or personal 2. Deflect the operating element in one of the possible injuryl!! directions. 5 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Safety – SIEMENS Healthineers Patient Rescue During Power Failure: Ceiling Releasing the brakes Moving the stand/C-arm manually 1 2 3 1 ▪ Open the clasp (1) at the ceiling suspension ▪ Once the belt has been released (3) the 3 holding the belt C-arm can be easily pushed away from ▪ Take the hook (2) out of the clasp and completely 2 the patient towards the end of the table. release the belt. 6 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Safety – SIEMENS Healthineers Patient Rescue During Power Failure: Ceiling Table rotation during power failure* After power has been restored ▪ Place the belt back in the ceiling rail and move the C-arm ▪ Pull out one of the two handles at the foot end of the patient table and hold it in that carefully back to the previous position until the belt is position. ▪ Rotate the patient table. tightened again. ▪ Close the hook again 1 and switch on the system. ▪ Please call the Siemens Service to ensure proper *Floor, biplane and zeego table are also the positioning of the C-arm. same. 7 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Safety – SIEMENS Healthineers Patient Rescue During Power Failure: Multipurpose Moving the stand/C-arm manually CPR support 1 3 1 3 Press the crank handle down on the Remove the covering cap 1 and For maximum stability of the table a right behind the support arm 1 insert the crank handle into the dedicated support base, the CPR , swing it out 2 and remove it from opening 2 Make sure that the support, must be used. It must be , . the holder 3 crank handle engages. Turn the crank adjusted to the appropriate height and . handle to set the height of the stored close to the patient table for tabletop 3 easy and quick access. . 8 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Safety – SIEMENS Healthineers Patient Rescue During Power Failure: ARTIS zeego Releasing the brake (1) 1 2 1. Open the cover on the rear of the stand 2. Open the flap. 4. Pull the button (1) on the handheld to base. 3. Take out the handheld. release the brakes. Note: Only the brakes for stand swivel and C-arm rotation are released. Movements of the other axes remain blocked. 9 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Safety – SIEMENS Healthineers Patient Rescue During Power Failure: ARTIS zeego Moving the stand/C-arm manually (2) 5. Rotate the C-arm so that there 6. Swivel the stand to clear space. 7. Press the button (2) on the handheld is room to release the patient. to engage the brakes again. 10 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 System Basic Handling Safety – SIEMENS Healthineers Brake Test – ARTIS zeego The Artis zeego system requests a brake test regularly. The brake test must be performed in the Parking position. 1. Select the Parking position under System Positions. 2. Press down the Stand Control joystick and deflect it forward until the Parking position has been reached. The system drives to the Parking position. The message "Stand Test: Activate stand movement # s" is displayed. 3. Press down the Stand Control joystick and deflect it forward again. The brake test is started and the message "Stand Test running" is displayed. 4. The system performs the brake test for each axle. CARE +CLEAR 5. Continue pressing down and deflecting the joystick until the message "Stand Test: Successfully completed" is displayed. ! If no brake test has been performed in the configured time interval, the message "Stand test necessary within # days" will appear. After this time has expired, the stand speed will be reduced. The message " Reduced stand/table speed, Stand Test necessary" will appear. 11 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Footnote/Source/Disclaimer 12 Effective Date: 07/28/2020|HOOD05162003109264 Unrestricted © Siemens Healthineers, 2019
- Safety
- Zee
- Q
- Q.zen
- ARTIS