Artis Systems VD11 System Basic Handling - System Operation Job Aid
Artis Systems VD11 System Basic Handling - System Operation Job Aid
SIEMENS Healthineers System Basic Handling System Operation Artis zee, Artis zeego, Artis Q, Artis Q.zen VD11 Version 2019.07 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: Job Aid 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 Unrestricted System Basic Handling System Operation – SIEMENS Healthineers Table of Contents Switching on/off 3 Unit movements 4 System Positions 8 Direct Positions 10 Programmed Positions 11 2 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 System Basic Handling System Operation - SIEMENS Healthineers Switching On/Off Switching on Switching off End Session X Please ensure that the main switch is switched on and the emergency SHUTDOWN button is inactive. Log Off ... Shutdown System .. Restart System ... Restart Application ... Standby ... Cancel Help Press the power-on pushbutton on the system console Select Options > End Session... in the main menu. for more than 0.5 s and then release the button. The End Session dialog box is displayed. Reminder Do NOT Log Off the system! 3 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 System Basic Handling System Operation - SIEMENS Healthineers Unit Movements Table Control Module: Knob with floating tabletop (with or without servo assistance) Table lift Table tilt Unlock brakes for table rotation; LED lights up while function active Select lateral table tilt Lock lateral tabletop movement U Set isocenter Select orientation with a long press Switch laser light on/off with a short press 4 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 System Basic Handling System Operation - SIEMENS Healthineers Unit Movements Stand/C-arm Control Module Multifunction joystick rear view 1 (1) Dead man's switch for releasing movements 1 (2) Switching over from C-arm angulation to stand swivel (floor stand), stand longitudinal movement (ceiling stand), 2 2 2 or C-arm longitudinal movement and system lift (Artis zee multi-purpose) 3 (3) Rocker switch on the back: for lifting and lowering the Flat Detector 3 000 Programmed position System position +60+ AB AB Store position Set zero stop AB +0+ Linear movements O O O (Artis zeego) Select biplane simultaneous Select direct positions I, II, III angulation Single plane system Biplane system 5 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 System Basic Handling System Operation - SIEMENS Healthineers Unit Movements Collimator control module JE tlt Switch between wedge/finger filter Cardiac 20x20 FD Angio 30x40 FD (only with Angio collimator) 1 1 1 Reset collimator leaves and 2 filter diaphragms 2 2 ( 1 ) 11 - 0 + - 0 + A B - 0 + - + Switch image input format/zoom stage Single plane Biplane Single plane Biplane O Collimator/FD rotation 1 Filter joystick 2 Collimator joystick AB Select plane (only with biplane systems) 6 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 System Basic Handling System Operation - SIEMENS Healthineers Unit Movements Membrane keys on the FD C-arm rotation Laser light on/off (cran/caud angulations) C-arm orbital movement FD rotation (RAO/LAO angulations) (setting portrait/landscape) ............. FD lifting and lowering -> -> Longitudinal tabletop setting the SID - movement ......... 7 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 System Basic Handling System Operation - SIEMENS Healthineers System Positions Move to system positions 1. Press the System Positions key from the Stand/C-arm 3. Confirm the target position by pressing one control module. The corresponding menu appears on the (or both) side buttons. Assist screen as shown below. 2. Select the required target position by deflecting the stand/C-arm 4. Press the stand/C-arm joystick down and deflect it away joystick (of plane A) away from you or towards you repeatedly. from you until the target position has been reached. Ciao System Positions System Positions System Positions System Positions System Positions Patient Transfer Patient Transfer Patient Transfer Left Side Cardio Pulmonary Resuscitation 2 Head Side 1 2 Head Side 12 Head Side 2 Right Side 2 Transfer Footside 13 Left Side 3 Left Side 13 Biplane Head Side 3 Head Side 13 Transfer Headside 4 Right Side 4 Right Side, Table Rotated 4 Left Side 4 Left Side, Table Rotated 15" 4 Frontal 5 Automap 5 Left Side, Table Rotated 15 Biplane Left Side 5 Left Side, Table Rotated 30" 15 Lateral 6 Automap 6 Right Side, Table Rotated 6 Patient Transfer Artis ceiling Overtable 0) 7 Left Side, Table Rotated 7Parking 17 Undertable Artis floor 8 Automap B . Automap 8 Automap Artis biplane Artis zeego Artis multi-purpose 8 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 System Basic Handling System Operation - SIEMENS Healthineers System Positions System Position with rotated table for floor stand 2 1 1. Unlock the floor stand by pressing the unlocking button 2 . 2. Hold the stand at the location marked 1 to move it manually. lagoo 3. Swivel the stand to the required position and move it back and forth slightly until it engages. 9 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 System Basic Handling System Operation - SIEMENS Healthineers Direct Positions Storing system positions with a shortcut (direct positions I, II, III) You can save the three most frequently-used positions that you require for examinations to the direct positions I, II, III. These system positions stored with shortcuts are not listed in the system positions and are not stored on the system position list. 1. Move the unit to the required position. O 2. Press the store key. The LED on the key lights up. O O 3. Press the required position key. The current system position is stored under the selected direct position number. The previously stored position is deleted. 10 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 System Basic Handling System Operation - SIEMENS Healthineers Programmed Positions Store a programmed position 1. Move the unit to the required position. 2. Set the primary collimator and the filter diaphragms. 3. Press the Store key. The LED on the key lights up. The Programmed Positions menu appears on the Assist screen. 4. Select the required memory position (number) by deflecting the stand/C-arm joystick (of plane A) backward or forward repeatedly. 5. Press one or both buttons on the side of the stand/C-arm joystick (of plane A). The current system position is stored under the selected program number. (The previous position is deleted.) The LED on the store key goes out. The system returns to its original state. 11 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2019 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Footnote/Source/Disclaimer 12 Effective Date: 07/28/2020| HOOD05162003109248 Unrestricted © Siemens Healthineers, 2019
- ARTIS
- zee
- Q
- system operation