Artis Systems VD12: 3D Acquisition Video
This video demonstrates how to set up and perform 3D acquisitions using your Artis system.
Welcome to the Artis 3D acquisition workflow video. This video will demonstrate how to set up and perform 3D acquisitions using your artist system. 3D acquisitions are used to create either high contrast or soft tissue. Views of the pathology of the patient. The result from the 3D acquisition and the reconstruction creates ET like images. The results are often used in guided workflows like needle guidance, embolization, guidance, or others. To start the 3D acquisition, select the 3D acquisition protocol. You can use the 3D wizard to select the protocol and for acquisition guidance, you open the 3D wizard from the 4D task card on the TSC. Select the 3D acquisition protocol. Please note it is also possible to select the 3D protocol manually from the exam task card on the TSC. 3D examinations can only be performed in calibrated system positions. The available calibrated positions depend on the system type. Please confirm with your Siemens Healthineers application specialist, which calibrated positions are possible. To move the system to the starting position, press down on the left joystick and deflect the joystick away from you. The system moves to the start position for the 3D acquisition. When positioning the system, follow the guidance on the exam room. Display guidance messages appear for all steps of the acquisition workflow. It is a requirement for 3D acquisitions that the region of interest is positioned in the isocenter position. The region of interest in the center in the AP position. Perform fluoroscopy briefly. Using care position, adjust the table lanja, tude naley and transversely so that the region of interest is in the center of the field of view. To position the region of interest in the lateral position, press on the stand. See arm joystick and deflect the joystick away from you. Perform fluoroscopy briefly using care position. Adjust the tabletop height so that the region of interest is in the isocenter. The Optional Laser Cross might be of help during this step. When you are satisfied that the region of interest is positioned within the isocenter, you can continue with the 3D workflow and enter the test phase to prepare, move the system to the start position for the test phase. Press on the stand. See arm joystick and deflect the joystick away from you when the system is in the start position for the test phase, a message appears on the exam room display. It is important in the test phase to ensure that the area of rotation is free from possible collisions. Move any equipment away from the rotation zone, including the exam room display. To start the test phase, press down and deflect the joystick away from you. The See Arm will rotate around the region of interest. This test is performed at a slower speed than the later acquisition to allow a better reaction to possible required changes. Keep the joystick deflected. The test phase will end automatically. For automatic setting of acquisition parameters, you are prompted by the system at the end of the test phase to perform fluoroscopy. When the test phase is complete, the system is ready for acquisition. Before you start the 3D acquisition, ensure that you are prepared for the injection of contrast media if required. See arm rotation depends on the selected protocol. For example, in Der acquisitions the system will perform one. See arm rotation. If an injector is armed, the contrast agent will be injected. DSA acquisitions will involve three rotations of the C arm. The mask run the return rotation no X Ray and the fill run the injector will be started for the fill run. The system will wait the time that is set in the X Ray delay. Some acquisition protocols involve a bolus watching phase. After the mask run. For example, Dina Pve nuro acquisition can be released by the Hand Switch or the Footswitch. The contrast medium injection can be synced with the acquisition, or you can manually trigger the injection of contrast media using the injector interface. During the 3D acquisition, as the C arm rotates around the region of interest, the 2D images are shown on the exam room and control room displays. This allows you to see the anatomical structures and monitor the injection of contrast media. Continue to release X Ray hand Switch or footswitch until you are notified by the system that the 3D run is completed. An audible signal indicates that the acquisition is complete. When the 3D acquisition is finalized, the 3D acquisition program is automatically deselected, and a 2D acquisition program is selected by default. If configured, the system can be moved back to the working position prior to entering the 3D acquisition workflow.
Healthineers, Heatthineers, Heatthineers, Healthineers, Siemens Siemens Heatthineers Experience Cen.. Siemens Heatthineers Experience Cen Siemens Heatthineers Experience Cen. ettings Exam Image Quant DynaCT Liver Siemens 12345678 AXIOM-Ar-tis AXIOM-Artis AXIOM-ArtiS AXIOM-MS * 8/22/1978 8/22/2018 8/22/1978 VDIIC 160916 * 8/22/1978 8/22/2018 8/22/1978 8/2212018 22/ 01 2/20 Information Step Overview Step Contrast 4:37:20 PM 4:37:53 PM 4:20:59 PM CARD 6sOCT acdy 6sOCT 6sOCT ecdy Head side Left side 90.0kV OOkV 67.7 W 67 7 W 67.7 w 67 8 W 67.8 W 68.5 W 67.8kV 67 8 68 a w 686 W 900kV FL O.OkV 235.6 mA 376.5 mA 334.3 mA 00 f/s 65 f/s 7.5 p/s X-ray Dilution du ratio n Artis zeego Image Quant 6sDCT Body t$FLAngeosmooth_ t$FLAngesmooth_ UFLAnglosmooth_ WFLAnglosmootmv UFLAnglosmoottv_ d$FLAnglosmooth_ $FLAnglmsmooth_ U FLAnglosmooth_ $FLAnglosmootm_ ($FLAnglosmooth„ i$FLAnglosmooth_ $FLAng@smooth_ FL(-) Card Coro SIEMENS FL Angio smooth View Deta ult> Default> Artis zee floor Artis zee blone 1 min— min— mjn_ Artis zee floor Artis zee biplane Artis zee biplone FL Angio smooth UFLAnglosmooth_ Step Overview DR Overview 6SDCT Body 6sDCT Body 102 Healthineers, 7.5 p/s 00 f/s 15 f/s REF 00:00 00:00 | REF ROMP (Anatomical phantom images) ROMP DSA IVUS RDMP AS 6SDCT 6sOCT DDO FL Angio Review cm 48 D 360 cm 48 D 46 D 44 wc 1400 wc 1850 ww 3400 Store Reference LAO 900 LAO RAO 100' RAO ww 3400 wc 1400 ww 2300 3400 2300 A:Test Phase: Stan Fluoro to complete Test Phase 3D test phase: Auto, activate stand movement 3 Start Position: Activate stand movement 3D ISO: Faoetal. activate stand movement 3D test phase: Auto. activate stand movement 3D Start Position: Activate stand movement 30 Start Position: Activate stand mov.'ement ISOatiatral Activate stand movement 30 Start Position: Activate stand mcr.'ement 30 Start Position: Activate stand mcwement 30 Start Position: Activate stand movement 30 ISO: Frontal. activate stand mcwement 3D ISO: Lateral, activate stand movement 30 ISO: Frontal, activate stand muvement 30 Start Position: Activate stand mcvement tomtatic run: Activate stand movement Ready for 3D as Acquisition Time Ready for 3D 6s Acquistion Time Automatic run: Moving to target A:lnjector disabled, manual injection. 'Ilnjector disabled, manual Injectioru A:lnjector disabled, manual injection A:lnjector disabled. manual injection 3 Stat Posin: Activate stand movement Automatic run: Moving to target tomatic run: Mcwing to target tomatic rum Moving to target Start Position: Activate stand mcwement tomatic run: Moving to target 3D ISO: Lateral, activate stand movement 30 Start Position: Activate stand movement 30 ISO: Frontal activate stand mcwement Start Fluoro to complete Test Phase 'Injector disabled, Injector disabled, A:lnjector disabled, manual injection A:lnjector disabled, manual injection. manual mnjectiom manual injection manual Injection manual mjectiom Injection
- artis
- artis
- atris
- artsi
- interventional
- angio
- angiography
- artis Q.zen
- Q
- zen
- aqcuisition
- multipurpose