Artis zee Applications Training - syngo Advanced
Artis zee Applications Training - <i>syngo</i> Advanced
Select the link below to view the content Patient Data Start Select the link below to view the content. Online Help Start Select the link below to view the content. Study Data Start Select the link below to view the content. Choosing Exam Set from the Editor Start Select the link below to view the content. Then hover over the highlighted areas for detailed information. Acquisition Data Launch Base ImageHotspotsText BlocksImage FileAcquistion Mode - The acqusition mode that is currently being used is displayed here. Some examples of the different modes are Digital Subtracted Angiography (DSA), Digital Radiography (DR), Perivision (PERI), Dynavision (DYNA), and Cardiac (CARD).Current Exam Set - Displayed here is the current exam set. To change an exam set, click the "..." button next to the exam set name.Current Acquisition Program and Value - Here is the display of the actual program that is currently active. By using the drop-down arrow just to the right of the text box, you can choose from up to 4 programs that have been pre-programmed into the exam set.kV - tube voltage for acqusition in kilovolts calculated from Fluoroscopy or post acquisition.mA - Tube current for acqusition in milliamperes calculated from Fluoroscopyor post acqusition.ms - Pulse width for acquisition in milliseconds calculated from Fluoroscopy or post acquisition.Focus - Focal spot size calculated from Fluoroscopy or post acquisition.Scene - Maximum scene length in seconds.Cu mm - Copper filter for acquisition in millimeters.Current Frame Rate - This value is the current acquisition frame rate that will be used when the acquisition pedal is pressed. This ranges from a singe frame for DR acquisitions to 7.5 for DSA, as well as 30 or 60 frames per second for cardiac examinations, depending on system configuration. To change the frame rate, click the drop-down arrow just beside the numerical display and choose a new frame rate. Select the link below to view the content. Dominant Cells and Override Start Select the link below to view the content. Then hover over the highlighted areas for detailed information. Fluro Data Launch Base ImageHotspotsText BlocksImage FileCurrent Fluoro Program - Here is the display of the actual Fluoro program that is currently active.Elapsed Fluoro Time - Display of the elapsed Fluoro time is in hours, minutes and seconds. You will be prompted to reset the Fluoro timer at pre-determined intervals (usually 5 minutes). This will silence the alarm but will continue to measure the Fluoro time. The Fluro timer will be reset automatically when a new patient is registered into the system.kV - Tube voltage* for Fluoroscopy in kilovolts. * Setting range defined in the Fluoroscopy program can only be changed by customer service.mA - Tube current* for Fluoroscopy in milliamperes. * Setting range defined in the Fluoroscopy program can only be changed by customer service.ms - Pulse width* for Fluoroscopy in milliseconds * Setting range defined in the Fluoroscopy program can only be changed by customer service.Cu mm - Copper filter* in the Fluoro beam in millimeters. * Setting range defined in the Fluoroscopy program can only be changed by customer service.Current Pulserate - This value is the current pulserate that will be used during Fluoro. This ranges from 0.5 to 30 pulses per second depending on system configuration. This can be changed by clicking on the drop-down arrow just beside the numerical display and choosing a new pulserate. Select the link below to view the content. Changing the Current Fluoro Program Start Select the link below to view the content. Roadmap Start Select the link below to view the content. Display Modes Start Select the link below to view the content. Store Fluoro Start Select the link below to view the content. Store Reference Start Select the link below to view the content. Store Monitor Start Select the link below to view the content. Reset Fluoro Timer Start Select the link below to view the content. Then hover over the highlighted areas for detailed information. General System Data Launch Base ImageHotspotsText BlocksImage FileDisk Free - This is the remaining image space on the disk, displayed as a percentage of total image space.HU - This value indicates the thermal condition of the anode in the tube housing. If this value reaches 75%, an audible signal will sound to warn of a possible overload. Fluoro and acquisition can still be performed. However it is recommended that a dose-reduced Fluoro, low-frame rate and low-dose rate acqusition program be selected. Repeated exceeding of the HU threshold value can reduce the service life of the tube and an overload can cause permanent damage. Select the link below to view the content. Messages Start Select the link below to view the content. Mouse Functions Start Select the link below to view the content. Image Review Start Select the link below to view the content. Navigation Directories Start Select the link below to view the content. Image Overviews Start Select the link below to view the content. Post Processing Subtask Cards Start Select the link below to view the content. View Start Select the link below to view the content. Shutter Start Select the link below to view the content. Invert Start Select the link below to view the content. Zoom/Pan Start Select the link below to view the content. Image Start Select the link below to view the content. Flip Horizontal/Vertical Start Select the link below to view the content. DSA (Option) Start Select the link below to view the content. Move Mask Start Select the link below to view the content. Replace Mask Start Select the link below to view the content. Native Start Select the link below to view the content. Anatomical Background Start Select the link below to view the content. Pixel Shift Start Select the link below to view the content. Flexible Pixelshift Start Select the link below to view the content. Invert Start Select the link below to view the content. Zoom/Pan Start Select the link below to view the content. Opacification Start Select the link below to view the content. Averaging Start Select the link below to view the content. 2k Imaging (Option) Start Select the link below to view the content. Acquisition Size (Option) Start Select the link below to view the content. Adjust Subtask Card Start Select the link below to view the content. Windowing Start Select the link below to view the content. Edge Enhancment Start Select the link below to view the content. Text Annotations Start Select the link below to view the content. Free Text Annotations Start Select the link below to view the content. Programming Default Settings Start Select the link below to view the content. Left/Right Markers Start Select the link below to view the content. Turning Text Overlay Off Start Select the link below to view the content. Pointer Start Select the link below to view the content. Circle Start Select the link below to view the content. Line Start Select the link below to view the content. Polygon Start Select the link below to view the content. Arrow Start Select the link below to view the content. Manual Distance Calibration Start Select the link below to view the content. Auto ISO Calibration Start Select the link below to view the content. Auto TOD Calibration Start Select the link below to view the content. Measure Distance Start Select the link below to view the content. Measure Angle Start Select the link below to view the content. Store Monitor Start Select the link below to view the content. Important Notes on Postprocessing Start Select the link below to view the content. Close Patient Start QCA (Quantitative Coronary Analysis) - for measuring and analyzing coronary arteries QVA (Quantitative Vascular Analysis) - for measuring and analyzing arterial segments other than the coronary arteries. LVA (Left Ventricular Analysis) - for determining the ejection fraction and wall motion of the left cardiac ventricle. Select the link below to view the content. Calibration Methods Start Select the link below to view the content. Auto ISO Start Select the link below to view the content. Auto TOD (less then 15°) Start Select the link below to view the content. Auto TOD (15° and above) Start Select the link below to view the content. Catheter Start Select the link below to view the content. Distance Start Select the link below to view the content. Sphere Start Select the link below to view the content. Manual Calibration Factor Entry Start Select the link below to view the content. Operation in the Control Room Start Select the link below to view the content. QVA and QCA (Option) Start Select the link below to view the content. Marking Vessel of Interest Start Select the link below to view the content. Automatice Reference Analysis Start Select the link below to view the content. Normal Report Start Select the link below to view the content. Detailed Report Start Select the link below to view the content. LVA (Option) Start Select the link below to view the content. Define End-Diastole Image Start Select the link below to view the content. Automatic Contour Detection Start Select the link below to view the content. Countour Correction Start Select the link below to view the content. Define End-Systole Image Start Select the link below to view the content. Manual Contour Detection Start Select the link below to view the content. Toggle between ED and ES Images Start Select the link below to view the content. Loop Images under Contour Start Select the link below to view the content. Normal Report Start Select the link below to view the content. Detailed Report Start Artis zee Applications Training syngo Advanced
- artis
- syngo