Atellica® CH Analyzer Monthly Maintenance PEP to Go Version 1.25 and Below
PEP to Go is an education resource material designed to support competency mastery on-the-job.
SIEMENS Healthineers Atellica® CH Analyzer Monthly Maintenance PEP to Go 1 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020 Atellica® CH Analyzer SIEMENS Maintenance Healthineers Monthly Maintenance ➢ Clean CH Fan Filters ➢ Clean and Inspect the CH Probes and Mixer Impellers ➢ Clean and Inspect the CH Probe Wash Stations 2 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020 Atellica® CH Analyzer SIEMENS Monthly Maintenance Healthineers Clean the CH Fan Filters The CH Analyzer has 1 filter located inside the left front door and 2 filters on the back left and center panels. Clean and inspect the fan filters monthly to ensure they are free from dust, dirt or debris. 1. Grasp the top or side of each fan filter and pull it up and out of the slot 2. Inspect and discard damaged filters 3. Rinse the filter with tap water 4. Tap the filter to remove excess water and let it air dry 5. Reinstall a spare fan filter with the plastic grid facing away from the panel or door 6. Mark Cleaning the CH Fan Filter as completed in the Maintenance > Schedule screen 7. If original filter discarded, order a replacement filter Note: The customer parts kit includes spare fan filters. Use a spare filter while the cleaned filter dries. When dry, place the cleaned filter in the customer parts kit for future use. 3 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020 Atellica® CH Analyzer SIEMENS Monthly Maintenance Healthineers Cleaning and Inspecting CH Probes and Mixer Impellers 1. Enter the system into Diagnostic State: A. Navigate to the CH Status screen: System > Operator Diagnostics > CH icon B. Select Enter Diagnostics > Yes 2. Wait for analyzer to enter diagnostic state 3. Under Subsystems, select Inspect and Clean 4. Select Cleaning and Inspecting the CH Probes and Mixer Impellers 5. Select Perform > Yes 6. Wait for analyzer to prepare for maintenance. Lift open the CH front and back covers 7. To protect the cuvettes from debris, cover with paper towel 8. Inspect the exterior of each impeller/probe 9. Wipe off any debris on each impeller or probe with an alcohol pad or lint-free tissue dampened with alcohol Note: Do not touch the probe tip when working with the probes. The probe tip is sharp and can cause bodily harm. *Procedure is continued on the next slide. 4 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020 Atellica® CH Analyzer SIEMENS Monthly Maintenance Healthineers Cleaning and Inspecting CH Probes and Mixer Impellers (continued) 10. Remove and discard the paper towel from the cuvettes 11. Close the CH cover 12. Select Continue > Close 13. Select Exit Diagnostics > Yes - 14. Mark Cleaning and Inspecting CH Probes and Mixer Impellers as complete in the Maintenance > Schedule screen O UL 94V-8 5 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020 Atellica® CH Analyzer SIEMENS Monthly Maintenance Healthineers Inspecting and Cleaning the Probe Wash Stations 1. Enter the system into Diagnostic State: A. Navigate to the CH Status screen: System > Operator Diagnostics > CH icon A B C B. Select Enter Diagnostics > Yes 2. Wait for analyzer to enter diagnostic state D 3. Under Subsystems, select Inspect and Clean 4. Select Inspecting and Cleaning the Probe Wash Stations > Perform > Yes 5. Wait for analyzer to prepare for maintenance. Open the CH front and back covers 6. To protect the cuvettes from debris, cover with paper towel 7. Inspect each probe wash station A. Dilution Probe B. Sample Probe E O C. Reagent Probe 1 D. Reagent Probe 2 E. IMT Wash Station 8. If appropriate, wipe off any debris on the wash station with an alcohol pad or lint-free tissue dampened with alcohol 6 *This procedure is continued on the next slide. Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020 Atellica® CH Analyzer SIEMENS Monthly Maintenance Healthineers Inspecting and Cleaning the Probe Wash Stations 9. Remove the paper towel from the cuvettes and discard 10. Close the CH covers 11. Select Continue > Close 12. Select Exit Diagnostics > Yes 13. Mark Inspecting and Cleaning the Probe Wash Stations as completed in the Maintenance > Schedule screen O 7 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2020 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 8 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020
- attelica
- attellica
- atelica
- chemistry