Atellica® Data Manager Configure QC Population Status Job Aid
This job aid provides instructions on how to configure a QC population status.
Configure QC Population Status Atellica® Data Manager Configure a QC Population Status 1. From the Command bar, select QC 2. Select the QC Population Status tab 3. In the Filter area, select the desired filter options 4. Select Apply 5. To change the status of a QC population to active: i. Highlight the appropriate population ii. Select Set Active 6. To change the status of a QC population to inactive: i. Highlight the appropriate population ii. Select Set Inactive 7. To change the status of a QC population to evaluating: i. Highlight an active population ii. Select Set Evaluating iii. Enter an Active date: and an Inactive date:, if desired. The dates must be in the future when entering active and inactive dates Healthineers Atellica ® Data Manager VM-TST-ADMEX Home Sample Query Browser Review and Edit Utilities ... Results Alerts Graph QC Population Status 2 :ilter QC Population Status Status QC lot Instrument Test Active date/time Inactive date/time New W L181114073240_48 AUT_Instrument1 AFP 14/11/2018 07:32 Edit + Test QCLot1 AUT_Instrument1 AUT_CalcEnu .. - 14/11/2018 07:02 View Instrument Group AUT_Instrument1 AUT_CalcEnu ... 14/11/2018 07:02 Delete Instrument QCLot1 AUT_Instrument1 AUT_NormalTest 14/11/2018 07:02 Select First to Current MISPL Filter L181114071724_10 AdviaCentaur_1 c101 14/11/2018 07:17 Select Current to Last 14/11/2018 07:17 Type Con LOT_0707 AdviaCentaur_ c101 Duplicate LOT_CRIT5 AdviaCentaur_1 c101 14/11/2018 07:18 Species Advanced QCL1 AdviaCentaur c101 14/11/2018 07:17 Custom Actions LOT_CRIT5 AdviaCentaur_1 c102 4/11/2018 07:18 Show Active LOT_POINTS3 AdviaCentaur_1 c102 14/11/2018 07:18 5 Show Evaluating Set Active LOT_CRITS AdviaCentaur_ c103 14/11/2018 07:18 Set Inactive Show Inactive LOT_EFR0102 AdviaCentaur_1 c103 14/11/2018 07:18 IK K AdviaCentaur_1 Set Evaluating LOT_NORMALIS 01 C103 14/11/2018 07:18 LOT_POINTS1 AdviaCentaur_1 0103 14/11/2018 07:18 LOT_QC1_0102 AdviaCentaur_1 C103 14/11/2018 07:17 LOT_QC2_0102 AdviaCentaur_1 c103 14/11/2018 07:17 LOT STAT1 AdviaCentaur_1 c103 14/11/2018 07:18 4 Apply 1 selected sysman, Systemmanager Tuesday, January 1, 2019 - 17:50 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD05162002647849 Healthineers Jobaid: Effective Date: 6/17/2019 | HOOD05162003011637 Job Aid | Configure QC Population Status Effective Date: 6/17/2019 | HOOD05162003011637 8. To set active and inactive date and time values for populations: i. Double click on the appropriate population ii. In the Status area, enter the Active date: and Inactive date:; as appropriate iii. Select OK QC Population General Duplicate Method test: c102 Method instrument: AdviaCentaur_1 Cut Moving average QC lot: LOT_CRIT5 Copy Species: ? Choice list: 2 Paste Clear Status Active date: 14/11/2018 07:18:11 Inactive date: ? Advanced Custom Actions Statistics Target value: ? Target deviation (1SD): ? Reference value: ? Reference deviation: Cumulative N: 0 Current N: Current days to keep: 0 Ignored deviation count: ? Audit Last close out time: ? Last purge time: ? Last reprocess time: ? OK Cancel Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 2 of 3 Job Aid | Configure QC Population Status Effective Date: 6/17/2019 | HOOD05162003011637 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 3 of 3
- attelica
- attellica
- atelica
- adm
- atellica dm