Atellica® Data Manager QC Results Overview Job Aid
This job aid provides an overview of the QC Results tab and instructions on how to view and export QC results.
QC Results Overview Atellica® Data Manager View QC Results 1. From the Command bar, select QC 2. Select the Results tab 3. Select to expand the Filter slide-out panel, if applicable 4. Enter parameters to narrow the search 5. Select Apply Healthineers> Atellica ® Data Manager VM-TST-ADM -6 XX 2 Home Sample Query Browser Review and Edit Utilities Results Alerts Graph QC Population Status Filter + Filter Details Lot/Species Assessed String value Unit MS WS IS CS C F GH |3 |-2 1 1 1 2 3 Test Comments Instrument Group Instrument Comments nstrument Parse Comments From 01/01/2019 00:00 To 02/01/2019 00:00 4 Failed Westgard Comments Type Any User Comments Lot Flags Species Sort by Test-Lot-Assessed-Instr Include closed ou User Actions Mean SD CV% Show Graph Show Result Details 5 Apply Omit Add Comment Reset Severity ? sysman, Systemmanager Tuesday , January 1, 2019 - 22:06 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD05162002647849 Healthineers Jobaid: Effective Date: 6/24/2019 | HOOD05162003011683 Job Aid | QC Results Overview Effective Date: 6/24/2019 | HOOD05162003011683 QC Results Tab Overview A. Filter slide-out panel: enables operators to define filter criteria for the QC results the system displays in the browser B. QC Results browser: displays the QC results in a table format C. Statistics D. Button bar: displays result details and the Levy-Jennings graph, and omitting, adding comments and resetting severity for results E. Details slide-out panel: collapsible content sections on Comments, Flags and User Actions Sample Query Browser eview and Edit Tac Utilities ID ... Results Alerts Graph QC Population Status m Filter A QC Results (Test: PHTN, From: 01/01/2017 00:00:00, To: 02/01/2019 00:00:00) Details Test Instrument ot/Species Assessed String value Unit MS WS IS CS -3 -2 -1 2 3 Comments PHTN AdviaCentaur_1 10881 29/05/2017 07:37:26 1.0 ug/ml Instrument Comments Filter PHTN AdviaCentaur_1 40881 28/05/2017 13:10:59 1.01 ug/ml PHTN AdviaCentaur_1 40881 28/05/2017 11:51:14 0.89 ug/ml Parse Comments PHTN AdviaCentaur_1 40881 27/05/2017 09:30:35 1.01 ug/ml Failed Westgard Comments B PHTN AdviaCentaur_1 4088 26/05/2017 10:40:09 1.3 ug/ml Westgard Severity: 1 Across lot: 4-1s PHTN AdviaCentaur_1 40881 25/05/2017 07:43:14 1.19 ug/ml In lot: 4-1s PHTN AdviaCentaur_1 40881 24/05/2017 07:36:35 1.06 ug/ml User Comments PHTN AdviaCentaur_1 40881 23/05/2017 11:09:24 1.17 ug/ml Flags PHTN AdviaCentaur_1 40881 22/05/2017 11:37:23 1. ug/ml PHTN AdviaCentaur_1 40881 22/05/2017 10:01:09 0.89 ug/ml PHTN AdviaCentaur_1 40881 22/05/2017 08:37:09 0.84 ug/ml User Actions N SD CV% Target value 1.18 44.72 Show Graph Show Result Details C Current 461 1.24 0.56 Target deviation 0.12 Cumulative 0 Data range 248 1.28 0.65 51.08 D Omit Add Comment Reset Severity ? sysman, Systemmanager Tuesday, January 1, 2019 - 15:24 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 2 of 6 Job Aid | QC Results Overview Effective Date: 6/24/2019 | HOOD05162003011683 QC Results Browser Overview Test: test associated with the QC result o Background color of the Test column reflects the current status of the assay. If the assay’s QC severity is at or above its QC severity limit (and operators do not reset the severity), the background color is red Instrument: instrument associated with the QC result o Background color of the Instrument column reflects the current status of the assay. If the assay’s QC severity is at or above its QC severity limit (and operators do not reset the severity), the background color is red Lot/Species: lot number or the species name Assessed: date and time the instrument assessed the result String value: string representation of the result value o Background color of the String value cell will be red when the QC severity of the associated assay is at or above its QC severity limit Unit: unit as defined in the test MS: assay severity of the QC result o Background color: No color when MS is O, Yellow if MS is 1, Orange if MS is 2 and Red if MS is 3 or greater WS: Westgard severity value IS: instrument severity CS: choice severity C: checkmark appears when a result has associated comments displayed in the Details panels F: checkmark appears for QC results with flags displayed in the Details panel GH: indicates whether any assays of tests, other than the one the current QC result directly reflects on, have had their severity set by the current QC result Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 3 of 6 Job Aid | QC Results Overview Effective Date: 6/24/2019 | HOOD05162003011683 QC Results Graph Columns Overview The colored graph columns display the portion of the value relative to its population reference value and reference deviation. Colored zones represent the following number of standard deviations: Grey: between -1SD and 1SD Green: between -1SD and -2SD or 1SD and 2SD Yellow: between -2SD and -3SD or 2SD and 3SD Red: more than -3SD or 3SD Values within the graph columns display as one of the following: Arrow: outliers further than 4SD from reference Dot: QC results within the 4SD range Solid: non-omitted QC results Outlined: omitted QC results Tests with an Enumerated control data type display the following in the graph columns: A bullet point in the 0 column when the result choice severity is 0 A left arrow in the -3 column and a right arrow in the +3 column when the result choice severity is not 0 -3 -2 -1 T 2 3 O Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 4 of 6 Job Aid | QC Results Overview Effective Date: 6/24/2019 | HOOD05162003011683 Generate a QC Results Report 1. From the QC Results browser, select the appropriate QC results 2. Right click and select Report 3. Verify the appropriate settings are selected 4. Select OK Atellica ® Data Manager VM-TST-ADMX Home Sample Query Browser Review and Edit ac Utilities ... Results Alerts Graph QC Population Status Report Filter General settings Printer settings File settings Fax settings QC Results (From: 01/01/2017 00:00:00, To: 02/01/2019 00:00:00) Format: PDF ¥ Details Test Instrument Lot/Species 4| As Output type: Print 1 2 3 Jasper report template: ? Comments AFP AUT_Instrument1 L181114071 07/ v Preview Filter Instrument Comments AFP AUT Instrument1 L181114071 07 AFP AUT_Instrument1 L181114071 07 Parse Comments AFP AUT_Instrument1 L181114071. 07 AFP AUT_Instrument1 L181114071 07 Failed Westgard Comments AFP AdviaCentaur_1 L181114073 07 AFP AdviaCentaur_1 181114073 07 User Comments IL AFP AdviaCentaur_1 L181114073 07 AFP AUT_Instrument1 181114073 07 Flags AFP AUT_Instrument1 L181114073 07 AFP AUT_Instrument1 L181114073 07 AFP AUT_Instrument1 L181114073 07 AFP ALIT Instrument1 1181114073 User Actions N Target value Show Result Details Current Target deviation OK Cancel Cumulative 0 Data range Omit Add Comment Reset Severity ? sysman, Systemmanager Tuesday, January 1, 2019 - 18:07 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 5 of 6 Job Aid | QC Results Overview Effective Date: 6/24/2019 | HOOD05162003011683 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 6 of 6
- attelica
- attellica
- atelica
- adm
- atellica dm