Atellica® Data Manager Software Update Version 1.2
This job aid provides an overview of the Atellica Data Manager system software update version 1.2.
Atellica® Data Manager Software Update Version 1.2 Archive Note: The Archive tab will display on the command bar, even if the feature is not installed. The Archive tab requires additonal system requirements and is not available to all sites. For more information refer to the Atellica Data Manager Release Notes and IT Release Notes. The Atellica Data Manager (DM) archive functionality enables the operator to archive patient results for long-term storage, by moving patient results from the live database to the archive database. Within the Archive tab, operators are able to: • Configure individual patient samples to be archived or purged • Archived samples can be configured to include images, sample documents, and/or graphs • Perform a filtered search of archived patient samples • View archived patient samples • Export archived patient samples • Generate patient sample reports The Archive tab contains the following main areas: A. Filter – enables operators to select criteria to display desired archived samples B. Archived samples list – displays archived samples that contain the filter criteria C. Archive Status section – displays the status of the archive database D. View Details button – displays a detailed list of all related data on a sample E. Printer icon – enables operators to generate a Jasper PDF report of archived patient samples Healthineers Atellica ® Data Manager VM-TST-ADMX A EO Sample Query Browser Review and Edit Archive Traceability Utilities A Filter to '31/10/2019 00:00' tient ID Patient name Patient location Physician ID Collection DIT Creation DIT Aspiration D/T Archiving DIT Status |Sample t ... Select First to Current ample ID 20191024141644616 Clemons, Lynne URG JB 24/10/2019 09:30 16/02/2019 13:16 17/10/2019 09:31 24/10/2019 14:17 UPL Serum Select Current to Last Test :20191024141752386 Moon, Cathy URG 24/10/2019 09:30 16/02/2019 13:17 17/10/2019 09:31 24/10/2019 14:18 UPL Serum Advanced Collected From 01/10/2019 00:00:00 ›20191024141814627 Whitley, Damien ORG JB 24/10/2019 09:30 16/02/2019 13:18 17/10/2019 09:31 24/10/2019 14:18 UPL Archive Status Collected To 31/10/2019 00:00:00 20191024141835373 Bohannon, Dylan URG JE 24/10/2019 09:30 16/02/2019 13:18 17/10/2019 09:31 24/10/2019 14:18 UPL Samples 23 Patient Identifier 20191024141857135 Nobles, Veronica URG JE 24/10/2019 09:30 16/02/2019 13:19 17/10/2019 09:31 24/10/2019 14:19 UPL Whole blo. Last Added 24/10/2019 14:27 20191024141919559 Ash, Dana URG 4/10/2019 09:30 16/02/2019 13:19 17/10/2019 09:31 24/10/2019 14:19 UPL Whole blo Last Purged Patient Last Name 24/10/2019 14:25 20191024141318534 Renteria, Jack URG B 10/2019 09:30 24/10/2019 14:13 17/10/2019 09:31 24/10/2019 14:14 PND Serum Physician Identifier 20191024141427496 Lindsay, Gilber URG 10/2019 09:30 24/10/2019 14:14 17/10/2019 09:31 24/10/2019 14:15 REV Physician Last Name 20191024141535832 Valadez, Luke URG JB 24/10/2019 09:30 24/10/2019 14:15 7 24/10/2019 14:15 PND Serum Aspirated From 20191024141558220 Younger, Ann URG JE 24/10/2019 09:30 24/10/2019 14:15 17/10/2019 09:31 24/10/2019 14:16 PND Whole blo .. C Aspirated To 20191024141942095 Feldman, Stevie URG JB 24/10/2019 09:30 24/10/2019 14:19 17/10/2019 09:31 24/10/2019 14:20 REV Serum 20191024142012013 Messer, Staci URG JE 24/10/2019 09:30 24/10/2019 14:20 17/10/2019 09:31 24/10/2019 14:20 KEV Serum 20191024142045951 Steward, Ethan URG JE 24/10/2019 09:30 24/10/2019 14:20 17/10/2019 09:31 24/10/2019 14:21 REV Serum 20191024142119576 Liles, Monty URG JE 24/10/2019 09:30 24/10/2019 14:21 17/10/2019 09:31 24/10/2019 14:21 REV Serum 20191024142153938 Linder, Krista URG JE 24/10/2019 09:30 24/10/2019 14:21 17/10/2019 09:31 24/10/2019 14:22 REV Serum 20191024142227459 Kruger, Cara URG JE 24/10/2019 09:30 24/10/2019 14:22 ? 24/10/2019 14:22 PND Serum E Apply View Details D ? CE sysman, Systemmanager Sunday, December 1, 2019 - 21:27 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 16-Sep-2020 | HOOD05162003126120 Healthineers Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 Traceability The Atellica DM Traceability feature enables the capture of consumable information for reagents, calibrations, quality control (QC) lots and other consumables associated with the generation of a patient result and maintains traceability for auditing purposes. Traceability can help customers satisfy quality and compliance requirements by identifying which instrument and consumable materials were involved in the generation of a patient’s results. Within the Traceability tab, operators are able to: • Create new lots or replace expired ones • Perform a filtered search of existing lots • Associate lots with test methods • Set the status of lots to active or inactive • Perform a filtered search of patient results • View trace information for patient results • Export trace information for patient results • Define, view, and resolve expiration alerts for reagent, QC, calibration, and consumable lots • Define, view, and resolve trace alerts for reagent, QC, calibration, and consumable lots The new Traceability tab has four main areas of focus: Healthingers Atellica ® Data Manager VM-TST-ADM -ERX A EO Sample Query Browser Review and Edit Qc Archive Traceability Utilities Configuration Patient Results Expiration Alerts Trace Alerts • Configuration – enables the operator to review and manage the status of reagent lots, calibration lots and consumable lots • Patient Results – enables the operator to identify which consumables were involved in the generation of a patient’s results • Expiration Alerts – displays list of soon-to-expire and expired consumables for reagent, QC, calibration and consumable lots • Trace Alerts – optional feature to raise a warning when insufficient trace information is associated with a result SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 2 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 Traceability Configuration Enables the operator to review and manage the status of reagent, calibration and other consumable lots. Instruments that upload reagent lot information may be automatically configured. Currently, the following are the instruments for which reagent lot can be automatically configured and linked to a method: Instruments directly interfaced to Atellica DM: • Siemens Atellica Solution • Siemens ADVIA® Chemistry XPT • Siemens ADVIA Centaur® XPT • Siemens Clinitek Novus® • Siemens Atellica 1500 • Werfen IL ACL TOP Instruments interfaced to Aptio Automation: Note: Reagent lot information is automatically populated for instruments uploading information to Aptio Automation within the Reagent Lot field of the Result Manufacturing Record (10.01.03.08) and for which the automation driver extracts the information. • Siemens Atellica Solution • Siemens ADVIA Chemistry XPT • Siemens ADVIA Centaur XPT • Siemens Dimension Vista® • Siemens BN™ II System • Abbott Architect • Beckman Coulter AU5800 • Beckman Coulter DXI800 • Beckman Coulter AU680 • Diasorin Liaison XL • Fujibero Lumipulse 1200 • IDS i10 • Roche Cobas c513 • Snibe Maglumi • Tosoh AIA-2000 • Werfen IL ACL TOP SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 3 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 To facilitate full traceability of your laboratory instruments’ patient results, configuration of calibration, other consumables and reagent lots can also be setup manually as well as lot expiration information that enables use of Alert functionality. It is the responsibility of the operator to ensure that configuration information input into Atellica DM is correct. To manually create reagent, calibration and consumable lots: 1. From the Command bar, select the Menu icon 2. For Reagent lot creation: select Routine > Reagent lots • For Calibration lot creation: select Routine > Calibration lots • For Consumable lot creation: select Routine > Consumable lots 3. Select New 4. Specify the lot, serial number, name, expiration time, and any necessary comments 5. Select OK Calibration lot Lot Duplicate Serial number: Cut Name: 2 Expiration time: Copy 2 Comment: Paste V Clear Advanced Custom Actions OK Cancel To add a method link: 1. Select Traceability > Configuration 2. Select the Reagent Lots, Calibration Lots or Consumable Lots tab 3. Select Add Method Link SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 4 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 thinkers Atellica ® Data Manager ADMDemo - 9 x EO. Sample Query Browser Review and Edit Archive raceability Utilities e Configuration Patient Results Expiration Alerts Trace Alerts Filter Reagent Lots Calibration Lots Consumable Lots Y Reagent Lots with Test 'Chol_2', Show Active "YES", Show Waiting "YES", Show Inactive "YES" Test Chol_2 Status & Lo Instrument Test Active date/time Inactive date/time Select First to Current Instrument Group PREAG_200002 Atellica1_CH930_1 Chol_2 04/07/2020 22:37 ? Select Current to Last PREAG_200002 Atellica2_CH930_1 04/07/2020 22:34 Advanced Instrumen Chol 2 PREAG_200002 Atellica1_CH930_2 Chol_2 Reagent Lot Related PREAG_200002 Set active Atellica1_CH930_3 Chol 2 ? Set Active Calibration Lot PREAG_200002 Set inactive Atellica2_CH930_2 Chol_2 Consumable Lot PREAG_200002 Atellica1_CH930_4 Chol_2 2 04/07/2020 22:39 Add Method Link Show Active Cancel Result Link Show Waiting K K Show Inactive Apply 1 selected ? sysman, Systemmanager Wednesday, May 20, 2020 - 1:07 4. From the Methods area, select the desired methods to be linked by moving them from the Available to Selected field using the right arrow button • The Search field can be used to filter the Available field by a specific Test Add Method Link Methods Reagent Lots Search O Select Existing Available Selected Search Selected Test Instrument Test Instrument Lot Lot New AFP AdviaCentaur_1 Reagent0420A, 123, Name, 06/01/2020 23:51:00 aHAVM AdviaCentaur_1 aHAVT AdviaCentaur_1 aHBcM AdviaCentaur_1 aHBcT AdviaCentaur_1 aHBs AdviaCentaur_ ALSCRN AdviaCentaur_1 ATG AdviaCentaur_1 aTPO AdviaCentaur_1 BNP AdviaCentaur_ BR AdviaCentaur_1 c AdviaCentaur_1 c101 AdviaCentaur_1 c2 AdviaCentaur_ c202 AdviaCentaur_1 Create New Apply OK Cancel SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 5 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 5. To link an existing reagent lot, from the Reagent Lots area, select the desired reagent lots to be linked by moving existing lots to the Selected field using the right arrow button • The list of available lots does not contain expired lots 6. To link a new reagent lot, from the Reagent Lots area: a. Select the Create New radio button b. Specify the lot, serial number, name, expiration time, and any necessary comments c. Move the created lot to the Select field using the right arrow button 7. Select Apply Add Method Link Methods Reagent Lots Search Select Existing Available Selecte Search Selected Test Instrument Test Instrument Lot Lot New AFP AdviaCentaur_1 Reagent0420A, 123, Name, 06/01/2020 23:51:00 aHAVM AdviaCentaur_ aHAVT AdviaCentaur_1 aHBcM AdviaCentaur_1 aHBcT AdviaCentaur_1 aHBs AdviaCentaur_1 ALSCRN AdviaCentaur_1 ATG AdviaCentaur_1 aTPO AdviaCentaur_1 BNP AdviaCentaur_1 BR AdviaCentaur_1 c AdviaCentaur_1 C101 AdviaCentaur_1 AdviaCentaur_1 & c202 AdviaCentaur_ Create New Apply OK Cancel SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 6 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 Lots can be filtered by selection criteria. For example: • Identify all Reagent lots for Chol_2 • Identify all Calibration lots for CA • Identify all Consumable lots for VB12 Lots can also be filtered by status (active, waiting, inactive). Once a set of lots is displayed, the status of a lot or a set of lots can be changed between Active and Inactive by selecting the appropriate lot and selecting the Set Active or Set Inactive button. thinkers Atellica ® Data Manager ADMDemo - 8 X EO Sample Query Browser Review and Edit Archive raceability Utilities Configuration Patient Results Expiration Alerts Trace Alerts Filter Reagent Lots Calibration Lots Consumable Lots Y Reagent Lots with Test 'Chol_2', Show Active "YES", Show Waiting "YES', Show Inactive "YES" Test Chol_2 Status A Lot Instrument Test Active date/time Inactive date/time Select First to Current Instrument Group PREAG_200002 Atellica1_CH930_1 Chol_2 04/07/2020 22:37 ? Select Current to Last Instrumen PREAG_200002 Atellica2_CH930_1 Chol 2 04/07/2020 22:34 Advanced PREAG_200002 Atellica1_CH930_2 Chol_2 ? Reagent Lot Related PREAG_200002 Set active Atellica1_CH930_3 Chol 2 ? Set Active Calibration Lot PREAG_200002 Set inactive Atellica2_CH930_2 Chol_2 Set Inactiv Consumable Lot PREAG_200002 Atellica1_CH930_4 Chol_2 2 04/07/2020 22:39 Add Method Link Show Active Cancel Result Link Show Waiting M Show Inactive Apply 1 selected CO ? 8 sysman, Systemmanager Wednesday, May 20, 2020 - 1:07 SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 7 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 Patient Results Operators can use the filter to: • Search for and identify which instrument and consumable materials were involved in the generation of a patient’s results • Identify all patient results generated for a specific consumable or all consumables used to process a sample Atellica ® Data Manager ADMDemo-Fx EO Home Sample Query Browser Review and Edit Qc Archive raceability Utilities ... Configuration Patient Results Expiration Alerts Trace Alerts Y Patient Results with Reagent Lot 'PREAG_221, PREAG_200002, Include Archived Results "YES Sample ID Availability .... Test Instrument QC lot QC exp. Calibration lot Calibration exp. Reagent lot Reagent exp. Consumable lot Cons Select First to Current ARF0051 04/08/2020 ... Chol 2 Atellica1_CH930_1 26431 PREAG_200002 03/01/2020 Select Current to Last Filter 26432 Advanced ARF0051 04/08/2020 .. Chol_2 Atellica1_CH930_1 26431 PREAG_200002 03/01/2020 26432 View Details ARF0003 04/08/2020 ... FSH Atellica1_IM1300_1 PREAG_221 ARF0003 04/08/2020. FSH Atellica1_IM1300_1 PREAG_221 ARF0003 04/08/2020 .. FSH Atellica1_IM1300_1 PREAG_221 ARF0003 04/08/2020. FSH Atellica1_IM1300_1 PREAG_221 ARF0006 04/08/2020 FSH Atellica1_IM1300_1 PREAG_221 ARF0006 04/08/2020 ... FSH Atellica1_IM1300_1 PREAG_221 ARF0007 04/08/2020 ... Chol_2 Atellica1_CH930_1 26431 PREAG_200002 03/01/2020 26432 ARF0007 04/08/2020 ... Chol_2 Atellica1_CH930_1 26431 PREAG_200002 03/01 /2020 26432 ARF0008 04/08/2020 .. Chol_2 Atellica1_CH930_1 26431 PREAG_200002 03/01/2020 26432 ARF0008 04/08/2020 .. Chol 2 Atellica1_CH930_1 26431 PREAG_200002 03/01/2020 26432 CO ? sysman, Systemmanager Wednesday, May 20, 2020 - 2:16 Expiration Alerts Expiration alerts can be generated for reagent, calibration and consumable lots that have expiration times configured. Expiration Alerts sub-tab displays a yellow indicator bar and the Traceability tab displays a yellow tab – indicates a lot will soon expire within a configurable number of hours: EO Review and Edit QC Archive Traceability Expiration Alerts Trace Alerts SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 8 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 Expiration Alerts sub-tab displays a red indicator bar and the Traceability tab turns red – indicates a lot has expired: Traceability Expiration Alerts Trace Alerts The Expiration Alerts screen has two main areas: the Alerts field and the Methods field. The Alerts field displays a list of colored cards with the name of the soon-to-expire and/or expired reagent, QC, calibration and consumable lots. • Yellow cards indicate soon-to-expire lots • Red cards indicate expired lots Since expired alerts are more severe than soon-to-expire alerts, expired alerts are prioritized and placed at the top of the Alerts field. Atellica ® Data Manager BE1-DEV-A-SN173 EO. Sample Query Browser Review and Edit Qc Archive raceability Utilities Configuration Patient Results Expiration Alerts Trace Alerts Alerts Methods (Consumable Lot: 'CONS_LOT_1' Expiration date: "22/10/2019 16:27') Test Instrument Select First to Current Consumable Lot CHOL AUT_TraceabilityInstrument Select Current to Last CONS_LOT_1 Advanced Consumable Lot ONS_LOT_2 Configure Set Inactive Consumable Lot CONS_LOT_3 Replace Lot QC Lot QC_TRACE_LOT3 A OC Lot OC_TRACE_LOT1 QC Lol OC_TRACE_LOT2 Calibration Lot CAL LOT Calibration Lot CAL_LOT_1 ? ysman, Systemmanager vrijdag 24 januari 2020 - 15:21 SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 9 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 To remove an alert, the operator must select a test method and then select Set Inactive. The operator can also choose to replace the lot by selecting Replace Lot to open the Lots Manager window and selecting an existing lot, existing waiting lot, or creating a new lot for the test method(s) which the soon-to-expire or expired lot applies to. Atellica ® Data Manager BE1-DEV-A-SN17 - X EO Sample Query Browser Review and Edit Archive traceability Utilities ... Configuration Patient Results Expiration Alerts Trace Alerts Alerts Methods (Consumable Lot: "CONS_LOT_1' Expiration date: "22/10/2019 16:27") Instrument Select First to Current À Consumable Lot Test AUT_TraceabilityInstrument Select Current to Last CONS_LOT_1 + CHOL dvanced Consumable Lot CONS_LOT_2 Consumable Lo Set Inactive CONS_LOT_3 Replace Lot QC Lot QC_TRACE_LOT3 QC Lot QC_TRACE_LOT1 A QC Lot QC_TRACE_LOT2 CAL_LOT_2 Calibration Lot CAL_LOT_1 ? sysman, Systemmanager vrijdag 24 januari 2020 - 16:21 Trace Alerts Optional feature that generates a warning when insufficient trace information is associated with a result and enabled at the Method level. For example, a test result is received but it has no associated active QC, reagent, calibration or other consumable lot created within Atellica DM, a trace alert would occur if configured on the method. Trace Alerts sub-tab displays a red indicator bar and the Traceability tab turns red – indicates a trace alert has become active: Traceability Trace Alerts SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 10 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 If trace severity is configured on the method, patient result trace severities associated with the alert are shown on the Review and Edit tab, and the associated test method is disabled until traceability information is assigned. To remove an alert, the operator must assign a lot to the patient result by selecting Assign Lot and selecting a new lot for the patient result. Trace alerts can also be resolved by validating patient results in the Review and Edit tab. Healthincer?? Atellica @ Data Manager VM-TST-ADMX EO. ne Sample Query Browser Review and Edit Archive Traceability Utilities ... Configuration Patient Results Lot Assignment Exp Reagent 1 selected results Alerts Patient Results (Missing trace Select Existing Waiting Available since Sa Select First to Current Oc Search Selected TraceMissingOCT 24/10/2019 14:31 AA Select Current to Last AUT TraceSeveri. Lot Lot New Advanced Consumable Lot TraceMissingCon AUT TraceSeven Assign Lot Calibration Lot TraceMissingCalT AUT TraceSeven TraceMissingRea. AUT TraceSeven .. Select Existing Create New Method Test TraceMissingReagTest Instrument AUT_TraceSeverityInstrument1 Status Enabled Also Assign Selected Lot(s) to Method 1 selected Enable Test after Lot Assignment ? CD sysman, Systemmanager OK Cancel Monday, March 9, 2020 - 15:32 Additionally, operators are able to generate a Jasper PDF report of trace information for patient results using the Print icon. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 11 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 Active Directory Active Directory is a tool outside of the main Atellica DM application for use by system administrators, supported by Atellica DM. Active Directory enables system administrators to manage user profiles and settings without accessing the Atellica DM application. If password verification is set to Active Directory Domain Services (AD-DS) and a user incorrectly enters their log in information, an error message appears. • In this example, the user is instructed to “Call Laboratory IT Help Desk at extension 123” SIEMENS Healthineers Atellica® Error x Access denied Call Laboratory IT Help Desk at extension 123 OK Next Exit This contact entry field is customizable for Atellica DM system administrators and enables administrators with system manager privileges to define contact information displayed when a user is denied access at the login screen. Note: When account password verification using active directory is enabled and a user experiences a login failure, users must resolve the error by contacting their facility’s administration and/or IT team. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 12 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 If password verification is set to Active Directory Domain Services (AD-DS) and single sign-on is enabled, Atellica DM checks the user's password against AD-DS records. With these settings, a user must simply log on to the operating system and double-click on the desktop icon to launch the Atellica DM application. The Atellica DM Login screen does not appear and no additional entry for credentials is required. • However, if a user has more than one role assigned, the Name field is automatically populated, and the user must select a role for the session at the Login screen before the application launches SIEMENS Healthineers .. Atellica® Data Manager Name JGSmith Role User: User [Default] User_Access_Westgard_Rules: User_Acce ... Next Exit Note: For more detailed information on Atellica DM software version 1.2 new features and functionalities refer to the Atellica Data Manager v1.2 Operator’s Guide and Release Notes. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 13 of 14 Job Aid | Software Update Version 1.2 Effective Date: 16-Sep-2020 | HOOD05162003126120 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and c autions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be comme rcially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples o nly. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Page 14 of 14
- attelica
- attellica
- atelica
- adm
- atellica dm