Atellica® Direct Load with IM (DL-I) Self-Guided Education Program
This program is designed for medical technologists who need to reinforce their knowledge and skills to operate the Atellica Solution successfully. This course will take you through the different resources available to you, at any time, via a computer or the instrument itself, focusing on the PEPconnect e-learning content.
Atellica® Direct Load IM (DL-I) Self-Guided Education Program Welcome to the Atellica Direct Load IM Self-Guided Education Program. This program is de- signed for Laboratory Professionals who need to reinforce their knowledge and skills to operate the Atellica Direct Load successfully. This course will take you through the different resources available to you, at any time, via a computer or the instrument itself, focusing on the PEPcon- nect e-learning content. 1. Follow the recommended PEPconnect learning modules below DL-IM New Operator PEPconnect Plan • System Overview ( estimated time to completion: 1 hr ) Atellica® Solution Software Overview Online Training (20 minutes) Atellica® IM Analyzer Hardware Overview Online Training (25 minutes) Atellica® Direct Load Hardware Overview Online Training (15 minutes) • Supply/Reagent Management ( estimated time to completion: 20 minutes ) Checking Reagent Status on the Atellica® IM Analyzer Video (3 minutes) Loading Reagent Packs on the Atellica® IM Analyzer Video (5 minutes) Checking Supply and Waste Status on the Atellica® IM Analyzer Video (1 minutes) Replacing System Fluids on the Atellica® IM Analyzer with the Sample Handler Video (4 minutes) Replacing Cuvettes on the Atellica® IM Analyzer Video (2 minutes) Replacing Sample Tips on the Atellica® IM Analyzer Video (2 minutes) Emptying the Solid Waste on the Atellica® IM Analyzer Video (2 minutes) • Quality Control ( estimated time to completion: 15 minutes ) Manually Ordering QC Tests on the Atellica® Solution Video (3 minutes) Automatic QC Scheduling on the Atellica® Solution Video (5 minutes) Reviewing QC Results on the Atellica® Solution Video (2 minutes) Printing QC Barcodes on the Atellica® Solution Job Aid (5 minutes) • Calibration ( estimated time to completion: 30 minutes ) Atellica® Solution Reagent Calibration Interval Training Interactive Video (5 minutes) Reviewing Calibration Status on the Atellica® Solution Video (8 minutes) Scanning MC TDEF Barcodes on the Atellica® IM Analyzer Video (2 minutes) Printing Calibrator Barcodes on the Atellica® Solution Job Aid (5 minutes) Reviewing Calibration Results on the Atellica® Solution Video (6 minutes) Job Aid Effective Date: 03/12/2022 | T18001.048 Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 • Sample Processing ( estimated time to completion: 15 minutes ) Manually Ordering Patient Tests on the Atellica® Solution Video (5 minutes) Filtering and Viewing Orders in the Worklist Overview Screen on the Atellica® (6 minutes) Solution Video Monitoring Sample Status on the Atellica® Direct Load Video (1 minute) Loading Samples on the Atellica® Direct Load Video (1 minute) • Maintenance( estimated time to completion: 5 minutes ) Inspecting and Emptying the Water Trap on the Atellica® IM Analyzer Video (2 minutes) Inspecting and Emptying the Dryer on the Atellica® IM Analyzer Video (2 minutes) Cleaning the Exterior of the Reagent Probes on the Atellica® IM Analyzer Video (2 minutes) • Troubleshooting ( estimated time to completion: 15 minutes ) Atellica® Solution Submitting Service Support Requests Video (9 minutes) Atellica® Solution How to Troubleshoot Errors Using the Operator Event Log Video (4 minutes) 2. Print the following resources available on PEPconnect by clicking on the links below: 1. Atellica Solution Competency Checklist 2. Atellica Solution Key Tasks for Basic Operation Job Aid 3. Using the Atellica Solution Competency Checklist, identify the competencies required for your role. Mark N/A if not applicable. Using the Atellica Solution Key Tasks for Basic Operation Job Aid, and the Online Help, complete the Hands-on exercise on the next page of this document. We recommend performing the hands-on exercises under the guidance of a trained Key Operator. 4. Once you are comfortable with the basic tasks, you can enroll in the 2-hour instructor- led virtual (E-Live) training programs by clicking on Register Now on the NAM ECM schedule: 1. Atellica Solution Calibration Virtual Training 2. Atellica Solution Troubleshooting Resources Virtual Training SIEMENS Page 2 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 Hands-on Exercise Explore the System Hardware and Software ( estimated time to completion: 10 minutes ) 1. Sign into the System (if needed) 2. Look above the Command Bar. What is your Atellica Solution software version? ____________________________________________________________________ 3. Open the System Fluids drawer. a. Where is fluid # 9 located? _________________________________________________________________ Navigate to the Command Bar, select the Samples Tab 4. What subtab is available to view samples? ____________________________________________________________________ Navigate to the Command Bar, select the Inventory Tab 5. Which subtab would you select to view the supplies status? _____________________________________________________________________ Select the IM module icon to view the supplies status 6. What is the status of the IM Cleaner (#9)? _____________________________________________________________________ For the following questions, access the On-Line Help (OLH) icon located on the Status bar. 7. Search Manually Mixing IM Reagents a. What is the minimum number of times IM reagent packs needs to be mixed? _______________________________________________________________________ Checking the System Health (Status) 8. At the Command Bar, select System > Status. SIEMENS Page 3 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 a. What is the status of the IM module? _______________________________________________________________________ 9. What color is currently displayed on your visual status light? __________________________________________________________________________ a. What does the color displayed indicate? (OLH: About Visible Status Light) _______________________________________________________________________ Reagent and Supply Management ( estimated time to completion: 20- 25 minutes) Reagent Overview At the Command Bar, select Inventory > Reagent Needs 1. In the Reagent Needs, are there any reagents listed? ________________________________________________________________________ 2. Review one reagent listed on this screen. a. Under the Reason column, what is the reason listed for this reagent in this screen. ____________________________________________________________________ b. How many packs do you need to load for this reagent? ____________________________________________________________________ At the Command Bar, select Inventory > Reagent Overview > IM icon 3. List one Immunoassay reagent that has a Valid calibration status. ______________________________________________________________________________________ 4. Use the Group by Reagent button to organize the reagent list. SIEMENS Page 4 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 a. How many humidity packs are onboard the IM module? _______________________________________________________________________ 5. Select one Immunoassay reagent and one Humidity pack then click on the Unload button. While the reagent is unloading, select Inventory > Reagent Loader to view the status of the packs. 6. Open the reagent tray drawer. a. Is the barcode label on the reagent packs oriented on the right or left side of the drawer? ________________________________________________________________________ b. What is the shape of the humidity pack? ________________________________________________________________________ 7. Close the reagent drawer to allow the packs to be reloaded. Supplies Overview At the Command Bar, select Inventory > Supplies Overview 1. What number is associated with the IM Cleaner? ___________________________________________________________________________ 2. What is the Onboard Stability of the IM Cleaner number 9? ___________________________________________________________________________ 3. How many containers of IM Wash are on board? ____________________________________________________________________________ 4. Refer to OLH Replacing IM System Fluids. a. List step 1 for replacing an IM system fluid. _______________________________________________________________________ 5. Refer to PEPconnect video: Replacing Cuvettes on the IM Atellica Analyzer a. What is the recommended way for the cuvette bag to be opened and handled? SIEMENS Page 5 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 _______________________________________________________________________ 6. Refer to PEPconnect video: Replacing Sample Tips on the IM Atellica Analyzer a. What step must be performed after the sample tip nest is installed but before closing the sample tip loading lid? __________________________________________________________________________ 7. Perform the following 2 tasks: a. Refer to OLH: Emptying the IM Sample Tip Tray Waste. b. Refer to OLH: Emptying the IM Solid Waste Sample Loading (estimated time to completion: 5 minutes) Loading Samples through the Direct Load 1. Place sample tubes in the appropriate Sample Rack 2. Load the rack on the Entrance Queue. a. How many samples can be loaded into a Sample Rack at one time? __________________________________________________________________ Quality Control ( estimated time to completion: 10-15 minutes) At the Command Bar, select Inventory > QC Needs 1. Review the QC Needs workspace to answer the following questions: a. Are there any QC materials listed that need to be loaded displayed in the screen? ______________________________________________________________ b. What column is highlighted in RED? _____________________________________________________________________ At the Command Bar, select QC > Create QC Orders SIEMENS Page 6 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 2. Creating a QC order (OLH Key Phrase: Creating QC Orders) a. Select a test from the IM Assay list. b. Select the + sign next to the level to place control into the Orders section of the screen. c. Select Edit Test Options for the assay. 1. List the options available to edit under Edit test option _______________________________________________________________________ 3. Click on REFRESH to remove this order. At the Command Bar, select QC > QC Definitions 4. Select a current definition by placing a checkmark in the box. 5. Click on Edit/View. a. Select the USAGE dropdown box. List the 4 usage options for a QC Definition _______________________________________________________________________ _______________________________________________________________________ _______________________________________________________________________ _______________________________________________________________________ Calibration ( estimated time to completion: 15-20 minutes) At the Command Bar, select Inventory > Calibration Needs 1. Are there any Calibrations displayed that need to be performed by the end of the day? _______________________________________________________________________________ a. If YES, what calibration material and/or reagent pack would need to be loaded to satisfy the need? _____________________________________________________________________ At the Command Bar, select Inventory > Reagent Overview. Select an assay with a Valid Calibration Status. 2. What is the Calibration Interval and Cal Type in Use? SIEMENS Page 7 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 _______________________________________________________________________________ 3. View the Reagent Details on the right side of the screen a. What is the Calibration Expiration? _____________________________________________________________________ b. What is the position location of this pack in the reagent compartment? _____________________________________________________________________ At the Command Bar, select Calibration > Calibration Results. 4. Under Attributes select Active. What glyph in the assay column indicates that the calibration is an active calibration? _________________________________________________________________________________ __ 5. Select an assay with a Valid result under the Cal Status column, then select the Details but- ton. a. View the Calibration Results Details. List the Assay and Calibrator Name. _________________________________________________________________________ Sample Management ( estimated time to completion: 15 minutes) At the Command Bar, select Samples > Sample List 1. Select the red and yellow filter boxes under Sample issues 2. Are there any samples requiring your attention listed in the workspace? ______________________________________________________________ At the Command Bar, select Patient Orders > Create Patient Orders. Refer to OLH About Cre- ate Patient Orders. 3. Create a patient order using sample ID 1234 with a x2 manual dilution a. Select 1 IM test. 4. Print the sample barcode before saving the patient order. SIEMENS Page 8 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 5. When creating manual orders, how would IM replicates be ordered? _________________________________________________________________________________ _________________________________________________________________________________ At the Command Bar, select Worklist > Worklist Overview 6. Use the filter to view samples with the below statuses. a. Ordered b. In process c. Intervention needed d. Completed 7. Select Ordered filter to view the order you just created. a. Why must the View Samples button be selected when changing filters? _________________________________________________________________ 8. How is the diluted sample identified in the software? ________________________________________________________ 9. Select the new patient order you created and select Delete Order. Maintenance Overview (estimated time to completion: 15 minutes ) At the Command Bar, select Maintenance > Schedule Access the Procedure Details to answer the following questions. 1. Use the filters to identify daily maintenance activities for the Direct Load (DL). a. How do you verify these activities passed? ______________________________________________________________________ 2. Use the filters to locate the daily IM maintenance activities. a. What supplies are needed to complete the daily IM maintenance activity? _____________________________________________________________________ SIEMENS Page 9 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 3. Use the filters to locate the weekly IM maintenance activities. a. What must be used to clean the reagent probes? _____________________________________________________________________ 4. Use the filters to locate the monthly IM maintenance activities. a. What must be used to clean the aspirate probes? _________________________________________________________________ b. How many filters does the DL analyzer have? _________________________________________________________________ Troubleshooting ( estimated time to completion: 15-20 minutes ) At the Command Bar, select System > Logs > Operator Event Log 1. Using the Filter options, select a Time and a Module to review. 2. Place a checkmark in the Errors box. a. Why do you have to click on the Display Events button when you use the checkboxes in the Filters area of the screen? ____________________________________________________________________________ 3. Select an error event and locate the corrective action to be performed using Event Help. a. How can you differentiate between an error and a warning? ____________________________________________________________________________ Creating a Service Support Request 4. What icon in the Status Bar allows the operator to create a Service Support Request Ticket? ______________________________________________________________________________ Refer to the Rebooting Job Aid in PEPconnect. SIEMENS Page 10 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 5. What steps can be taken to recover from a slow user interface? _______________________________________________________________________ _______________________________________________________________________ 6. Will patient processing continue during a PCC restart? _____________________________________________________________________________ 7. If the IM module is powered off for more than 30 minutes, how are the onboard reagents to be handled? _____________________________________________________________________________ SIEMENS Page 11 of 12 Healthineers Job Aid | Atellica® Direct Load IM (DL-I) Self-Guided Education Program Effective Date: 03/12/2022 | T18001.048 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and sha ll by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 SIEMENS Page 12 of 12 Healthineers