Atellica® Inventory Manager Changing Label Roll and Ribbon Job Aid
This job aid provides instructions on changing the label roll and ribbon on the SATO GL408e printer.
Changing Label Roll and Ribbon Job Aid Atellica® Inventory Manager Changing the Label Roll The following procedures are for SATO GL408e printer. CAUTION Do not touch parts inside the printer before letting the printer cool to room temperature. Internal areas of the printer can be hot and cause physical injury. Supplies needed: Label roll ordered through Siemens. Refer to the Aptio Inventory Manager Operator’s Guide for the part number. 1. On the printer, press the LINE button to take the printer offline. The ONLINE LED Indicator will go off and OFFLINE will appear on the display GL408e OFFLINE POWER ON LINE STATUS LABEL RIBBON LINE SHED UNCTION ENTER CANCEL Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 SIEMENS Master Template Effective Date: 3/11/2019 | HOOD05162002998095 Healthineers Job Aid Effective Date: 06/20/2019 | HOOD05162002996370 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 2. Turn off the power by pressing the “O” on the power switch 08/17/2015 O 3. Open the printer cover by lifting the side panel. Move the lavender print head latch all the way to the right to unlock the print head assembly Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 2 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 4. Retract the used label roll lead and remove the empty label roll 5. Place the new label roll on the roll paper feeder. The label roll should rotate counter‐ clockwise and the print side of the label is facing up Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 3 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 6. Thread the labels between the media guide and printer wall, under the media damper and the lavender media sensor and then through the label slot on the front of the printer. Confirm that the labels are wound tightly 7. Align the outer edge of the labels with the inside label edge guide Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 4 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 8. Align the left edge of the labels (viewing the printer from the front) to about 4mm (1/8 in.) from the left side of the print head assembly, and align the black separator mark between the labels on the tear bar. Straighten the first label at the label slot to ensure the label is properly aligned Be careful of the cutter edge. 000896001 9. If needed, adjust the media guide (A) by loosening the lavender media guide knob (B), aligning the media guide (A) against the labels, and tightening the lavender media guide knob (B) B A Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 5 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 10. Move the lavender print head latch all the way to the left to lock the print head assembly. Check that the labels are properly aligned after the print head is closed 11. Close the printer cover GL406e Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 6 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 12. Turn the power on by pressing down on the "I" on the power switch 08/17/2015 O 13. Press the LINE button on the front of the printer to bring the printer Offline 14. Select FEED and ensure that the feeding mechanism is feeding the labels correctly so that the label stops with the black mark aligned with the tear bar 15. Perform a print test • Unlock the Enter switch by simultaneously pressing the down arrow and ENTER. OFFLINE displays • Press FUNCTION. Use the down arrow to scroll to DIAGNOSTICS and press ENTER • Select Printer Tests and press ENTER • Choose a print test: o Checkerboard o Grey o Grid • Press ENTER. The printer prints 5 test labels 16. Press the LINE button on the front of the printer to bring the printer Online Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 7 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 Changing the Ribbon Supplies needed: Ribbon ordered through Siemens. Refer to the Aptio Inventory Manager Operator’s Guide for the part number. Note: You may find it easier to remove the label roll before replacing the ribbon. Printer cleaning may also be performed when both the label roll and ribbon have been removed. After replacing the ribbon, reinstall the label roll before closing the print head. 1. On the printer, press the LINE button to take the printer offline. The ONLINE LED Indicator will go off and OFFLINE will appear on the display GL408e OFFLINE POWER ON LINE STATUS LABEL RIBBON LINE FEED FUNCTION ENTER CANCEL 2. Turn off the power by pressing the “O” on the power switch O 3. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 8 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 3. Open the printer cover. Move the lavender print head latch all the way to the right to open the print head assembly 4. Remove the used ribbon from the take‐up spindle (A) and the empty ribbon core from the ribbon supply spindle (B) 5. Install the empty ribbon core on the take‐up spindle (A) and push it all the way in on the spindle until it can go no further 6. Install the new ribbon on the ribbon supply spindle (B) so that the loose end (leader) is on the left side of the ribbon supply spindle, then push the ribbon roll all the way in A B Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 9 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 7. Thread the end of the ribbon under the print head (A) and then up to the right and over the take‐up core (B). Ensure the ribbon is not passing under the lavender media sensor (C) D B A C A 8. Ensure the ribbon is shiny side up at the top of the take‐up spindle. The matte side of the ribbon should be against the take‐up core and facing the labels as they come out of the label slot GL408e ONES OVINE FATE USE RACTION BCE CANCEL Be careful of the cutter edge Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 10 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 9. Attach the ribbon to the take‐up core. Manually rotate the take‐up spindle counter‐ clockwise until the ribbon leader has passed the print head and the ribbon is taut. Ensure there are no wrinkles in the ribbon GI408e O 10. Reinstall the label roll if removed 11. Move the lavender print head latch to the left to close the print head assembly Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 11 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 12. Close the cover GL408 13. Turn the power on by pressing down on the "I" on the power switch O - Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 12 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 14. Press the LINE button on the front of the printer to bring the printer Offline 15. Select FEED and ensure that the feeding mechanism is feeding the labels correctly so that the label stops with the black mark aligned with the tear bar 16. Perform a print test • Unlock the Enter switch by simultaneously pressing the down arrow and ENTER. OFFLINE displays • Press FUNCTION. Use the down arrow to scroll to DIAGNOSTICS and press ENTER • Select Printer Tests and press ENTER • Choose a print test: o Checkerboard o Grey o Grid • Press ENTER. The printer prints 5 test labels 17. Press the LINE button on the front of the printer to bring the printer Online Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 13 of 14 Job Aid | Changing the Label Roll and Ribbon Effective Date: 06/20/2019 | HOOD05162002996370 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica is a registered trademark of Siemens Healthcare Diagnostics. Copyright © Siemens Healthcare GmbH 2019 ……………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84‐0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 14 of 14
- products
- RFID
- cloud
- antenna
- AIN
- atelica
- attelica
- attellica
- GL408e