Atellica® Sample Handler Connect Daily Maintenance PEP to Go Version 1.25 and Below
PEP to Go is an education resource material designed to support competency mastery on-the-job.
SIEMENS Healthineers Atellica® Sample Handler Connect Daily Maintenance PEP to Go Effective Date: 3/12/2018 | HOOD05162002822811 Unrestricted © Siemens Healthcare GmbH, 2018 Atellica® Sample Handler Connect SIEMENS Daily Maintenance Healthineers Daily Maintenance Perform Sample Handler Connect (SHC) Autocheck 2 Effective Date: 3/12/2018 | HOOD05162002822811 Unrestricted © Siemens Healthcare GmbH, 2018 Atellica® Sample Handler Connect SIEMENS Daily Maintenance Healthineers SIEMENS Build 1.7.0 DL-P1-07 Performing Automated SHC Autocheck Activity 160 K 1 System Samples Inventory Calibration Patient Orders Worklist Maintenance Setup 2 Schedule Report Log Diagnostics Data Restore Software Updates Copy Configuration The SHC Autocheck is an automated maintenance activity Filter Module SHC Frequency. All Time Next 24 hours Performed By: All that tests the health of various SHC components. Module SHC Scheduled Tue-25 Wed-26 Thu-27 Fri-28 Sat-29 Sun-30 Mon 4 Module Activity Frequency All 3 SHC Autocheck 428/2017 1:00 Mark an Comparted The system alerts the operator 15 minutes before the Time Next 24 hours scheduled activity begins. After the system initiates the Performed By All Search Text Entor the activity name. Procedan Detal SHC Autocheck, the SHC pauses sample transfer until the Scheduled by Operator Fris View autocheck completes in approximately 5 minutes. Scheduled Automatically Delde Off Scheduled by Service The task will run automatically daily, but can be run Failed manually if needed: Overdue Inprocess ¥ Completed 1. On the Command bar, select Maintenance X Not Performed With Comments 2. Select the Schedule tab 3. Select SHC Autocheck Add Activity- Set Warning . 4. Select Perform ? PEP LabManager Thursday, June 08. 2017 11:41:55 AM ofa 5. Wait for autocheck to complete 3 Effective Date: 3/12/2018 | HOOD05162002822811 Unrestricted © Siemens Healthcare GmbH, 2018 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2018 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 4 Effective Date: 3/12/2018 | HOOD05162002822811 Unrestricted © Siemens Healthcare GmbH, 2018
- attelica
- attellica
- atelica