Atellica® Solution Copying System Configurations Job Aid Version 1.25 and Below

This job aid provides instructions on how to copy system configurations on the Atellica® Solution.

Atellica® Solution SIEMENS Copying System Configuration Job Aid Healthineers System configurations, such as maintenance schedules, can be SIEMENS Healthineers Atellica® Solution Version 1.15.0.3080004 P-P1-04 copied from one system and applied to another system of the 1 System Samples Inventory Calibration Qc Patient Orders worklist Maintenance Setup same type using the same software version. 2 Schedule Report Log IMT Data Restore Software Updates Copy Configuration Export configuration settings Browse and Import Configuration Settings • Applying a configuration copied from another system System Serial Number P-P1-04 Select Configuration Settings Select the configuration file to Apply System Name P-P1-04 All Browse overwrites any configurations that are on a system Test Definitions, Assay List, Ranges, Repeat Conditions, Reflex Group Setup, and Test Display Order 3 Export Configuration System Serial Number Ratios, Panels, and Off-System Date and Time After applying the copied configuration, operators must sign QC Definitions, QC Profiles and QC Schedules • System Name Directories in again Maintenance Schedules and Definitions Print Reports LIS Configuration Security Settings Operator Setup Exporting Configuration Settings: 1. On the Command bar, select Maintenance 2. Select Copy Configuration 3. Select Export Configuration Import 4. Browse to location for the exported system configuration ? PEP LabManager file Wednesday, October 03, 2018 2:10 PM • The location in step 4 cannot be on the same disk as the system files 5. Create a password for the exported file 6. Select Save 1 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 6/30/2019 | HOOD0516200301019 Unrestricted © Siemens Healthcare GmbH, 2019 Atellica® Solution SIEMENS Copying System Configuration Job Aid Healthineers Importing Configuration Settings: SIEMENS Healthineers Atellica Solution Version 1.15.0.3080004 P-P1-04 1 System Samples 1. On the Command bar, select Maintenance Inventory Calibration Qc Patient Orders 2 Worklist Maintenance Setup Schedule Report Log IMT Data Restore Software Updates Copy Configuration 2. Select Copy Configuration Export configuration settings Browse and Import Configuration Settings 3 Select Configuration Settings System Serial Number P-P1-04 Select the configuration file to Apply All 3. Select Browse... System Name P-P1-04 Browse ... Test Definitions, Assay List, Ranges, Repeat Conditions, Reflex Group Setup, and Test Display Order Export Configuration System Serial Number P-P1-04 Ratios, Panels, and Off-System 4. Navigate to the folder where the operator saves the Date and Time 10/3/2018 2:12 PM 9 QC Definitions, QC Profiles and QC Schedules System Name P-P1-04 Directories exported configuration settings Maintenance Schedules and Definitions Print Reports 5. Select the file to Import LIS Configuration Security Settings Operator Setup 6. Select Open KK KK KK KK KK 7. Enter the password for the exported configuration settings file 8. Select Yes 10 Import 9. Select the configuration settings to Import CD 10. Select Import... ? PEP LabManager Wednesday, October 03, 2018 2:14 PM 2 Effective Date: 6/30/2019 | HOOD0516200301019 Unrestricted © Siemens Healthcare GmbH, 2019 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2019 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 3 Effective Date: 6/30/2019 | HOOD0516200301019 Unrestricted © Siemens Healthcare GmbH, 2019