Atellica® Solution Final Performance Exercise

This exercise can be used as a final review during basic operator training.

Final Performance Exercise Atellica® Solution Configuration:  Sample Handler  Direct Load  Chemistry Analyzer  Immunoassay Analyzer  Sample Handler Connect  Decapper Task #1: Daily Setup You are to perform the following, using any available reference and education tools as needed: 1. Utilize either Online Help or PEPconnect to find a list of the daily maintenance activities for each module on the system 2. Verify the automated daily maintenance activities have been completed 3. Perform the remaining tasks for daily maintenance 4. Check the status of the analyzer supplies 5. Load supplies and empty waste, as needed 6. Check the status of the reagents 7. Load a new reagent pack on each analyzer 8. Load a new IM primary reagent pack with a new lot, if applicable Task #2: Calibration You are to perform the following, using any available reference and education tools as needed: 1. Define a new calibrator for each analyzer 2. Manually create orders for the new calibrator(s) 3. Process a calibration for each analyzer 4. Determine if the calibration results are valid 5. Utilize either Online Help or PEPconnect to determine how to review calibrator result details that would be useful if a calibration result is not valid 6. Review the status of IMT calibration on the CH system (if applicable) Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 SIEMENS Master Template Effective Date: 3/11/2019 | HOOD05162002998095 Healthineers Job Aid Effective Date: 3/31/2019 | HOOD05162003000216 Final Performance Exercise Effective Date: 3/31/2019 | HOOD05162003000216 Task #3: Quality Control You are to perform the following, using any available reference and education tools as needed: 1. Create a QC definition for a new lot of QC 2. Manually create orders for the QC to be run that day 3. Process the QC orders on the system 4. Determine if the QC results have passed 5. Review the QC statistics for the QC results 6. Generate a report of the QC data for the past month 7. Utilize either Online Help or PEPconnect to review the procedure for managing QC lot crossovers Task #4: Patient Sample Processing You are to perform the following, using any available reference and education tools as needed: 1. Create manual patient sample orders 2. Utilize either Online Help or PEPconnect to review the procedure for creating batch orders 3. Process patient samples on the system 4. Monitor sample tube status 5. Review patient sample results Task #5: Maintenance You are to perform the following, using any available reference and education tools as needed: 1. Utilize either Online Help or PEPconnect to find a list of the weekly and monthly maintenance activities for each module on the system 2. Utilize either Online Help or PEPconnect to review the procedure for performing one of the weekly or monthly maintenance activities Task #6: Troubleshooting You are to perform the following, using any available reference and education tools as needed: 1. Locate the Operator Event Log on the system 2. Utilize Online Help to locate the corrective action for one of the errors in the Operator Event Log 3. Utilize either Online Help or PEPconnect to locate the procedures for shutting down the system and for starting the system Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 2 of 3 Final Performance Exercise Effective Date: 3/31/2019 | HOOD05162003000216 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be upd ated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2019 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2019 Page 3 of 3