Basic DynaCT MPR Workflow
Basic DynaCT: Multiplanar Reconstruction (MPR) Workflow Interventional Radiography: Cardiac Please see manual for complete system capabilities. 1. Acquire a DynaCT dataset. This will autotransfer to the XWP Workplace for manipulation. It can also be manually transferred, if needed. 2. The MPRs can now be manipulated to view anatomy and/or pathology Change slice thickness-Right click on Slice Properties icon. Change window values to preferred viewing contrast and brightness-Middle click and drag Manipulate planar lines to view anatomy or scroll through images-Left click and drag on colored lines Change the MPR viewing preset into a MIP (Maximum Intensity Projection) preset. MIPs are best used for enhancing contrasting, stents HEPATIC OCTO ESYPR 50mm 7/01 2011 7/14/1901 F DMBCT Body Nat Fil HU Normal In CRHUCSUD Type Orient Table 20 InSpace 1100 -o Brightness 40 205 Opacity 80 HEPATH OCTO. RERSHUIDESURF 7.09 2011 7/14/1991 F LACIRAD CRAUSUD East JoTors on OBnorad Hosp tal P Trick Sices 17:16:90 Sice thickness (mm) Auto-hide MPR Ines P Window all MPR views tooother Maintain orthogonal MPR views 3. MPR Ranges and/or single images can be made, stored, and sent to archive node. MPRs' and/or MIPs' Ranges can be saved directly to the Local Database (See additional Step by Step for MPR Ranges). From the Local Database, these ranges can be sent to archive node. Single images can be saved to the Local Database using the Save or Save As icon. From the Local Database, these images can be sent to archive node. SIEMENS siemens.com/healthineers Healthineers Job Aid | Basic DynaCT: Multiplanar Reconstruction (MPR) Workflow Effective Date: 09/08/2016 | Quality HOOD05162001259040 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2
- Artis One
- Artis Q
- Artis zee biplane
- Artis zee ceiling mounted
- Artis zee floor mounted
- Artis zeego
- Artis Zen
- Axiom Artis