PEPconnect

Body Coil 60 (Numaris X)

This job aid goes over the coil usuage and set up of the body coil 60.
 

Body Coil 60 (Numaris X) syngo MR Systems with Numaris X The combination of two Body 30 Coils (anterior /posterior) is referred to as “Body 60.” The Body Coil 60 enables examinations of the upper body, abdomen/liver, pelvis and heart. (1) B1 B4 83 B2 85 (2) (3) Body 60 setup (1) Coil plug (2) Coil element rows (clusters B1 - B5) (3) Frame to use the Body 30 as posterior coil POSITIONING: The Body 30 can be positioned in a frame and can then be used as posterior coil. Together with a second Body 30 as anterior coil, this setup is called “Body 60”. 1. The spine coil or table pads are removed from the patient table 2. Lay the Body 30 with the coil cables on the upper side on a plane surface a. Route the coil cables through the recess of the frame and position the frame on the coil so that the cable outlets of the coil and the electronic boxes fit in the corre- sponding recesses Restricted 1 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Job Aid | Body 60 (Numaris X) Effective Date: 05/27/20 | HOODHOOD05162003092551 3. Fix the coil cables on the cable holders on the lower side of the frame 4. Connect the adapter to the spine coil sockets 5. Insert the frame with the posterior coil in the T-shaped grooves on both sides of the patient table 6. Slide the frame to the desired position on the patient table Restricted 1 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 2 of 5 Job Aid | Body 60 (Numaris X) Effective Date: 05/27/20 | HOODHOOD05162003092551 7. Connect the posterior coil to the adapter coil sockets 8. Position the Body 30 table pad 4 on the adapter and fold it down to cover the coil sockets 9. Position the table pads on the patient table as required for the current coil position 10. Position the patient on the posterior coil with the head towards the magnet Restricted 1 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 3 of 5 Job Aid | Body 60 (Numaris X) Effective Date: 05/27/20 | HOODHOOD05162003092551 11. Position the anterior coil on the and secure the coil with the Velcro strap a. Note: When you use the Body 60 setup, ensure that the posterior and the anterior coils are positioned accurately above each other to avoid possible image artifacts 12. Connect the anterior coil to coil sockets 1 and 2 13. Secure the coil cables with the cable holders 14. Align the laser-light localizer with the center of the region of interest 15. Start the measurement 16. Please refer to Operator Manual–Coils for further information, including cleaning guide- lines Restricted 1 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 4 of 5 Job Aid | Body 60 (Numaris X) Effective Date: 05/27/20 | HOODHOOD05162003092551 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Restricted 1 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Page 5 of 5