Bold Evaluation (A-E Line)

BOLD Evaluation (A-E Line)

BOLD Evaluation A to E-line BOLD Evaluation is used to calculate parameter maps retroactively with syngo BOLD. The pixels of the post-processed parameter images carry functional information. 1. Select Applications > BOLD a. Prerequisite: BOLD Task Card must be open prior to loaded functional series into BOLD Evaluation 2. From the Patient Bowser > select Functional series a. Select Applications > BOLD Evaluation , and load the appropriate data set into the BOLD Task Card Applications Transfer Ec Neuro 3D (MR) Patient Browser Patient Applications Transfer Edit View Filter Evaluation Sort Options Help Report Open Report Tools ? ? Mosaic BREAST - MEAN CURVE [15] gre_field_mapping 3D BOLD NEURO 3D [16]t1_se tra Argus Local Database .... BOLD EVALUATION - 2D HEAD [21] ep2d_bold_moco BOLD Schedule BOLD / DTI / Perfusion [23] EvaSeries_tTest BOLD Evaluation DVD_READ ASL PERFUSION [24] EvaSeries tTest Soft Tissue (MR) DVD_WRITE ARGUS VF [25] Mean_& t-Maps R/com///// / 3. Evaluation Controller window opens Evaluation Controller Dialog x within the BOLD Task Card Series No. Description Images 95 act_ep2d_motor_cortex 16 (1)- 96 act_ep2d_motor_cortex 16 97 98 act_ep2d_motor_cortex 16 act_ep2d_motor_cortex 16 99 act_ep2d_motor_cortex 16 1. Selected Series (2) BOLD.evp 2. Post-processing protocol last used Execute Edit Protocol Delete Series Cance Help Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date:02/18/2020 | HOOD/HILS HOOD05162003063679 Job Aid | BOLD Evaluation – A-Eline Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063679 The MR System informs you about a series that doesn’t meet all requirements.  EPI Series/Measurements – must originate from same series block with identical table position, frame of reference, slice position, and number of images.  Requirement not meant – remove series from the list using “Delete Series” 4. Evaluation Controller Dialog > Select Postprocessing Protocol from selection list a. Start calculation > select Execute. Evaluation Controller Dialog X Series No Description ep2d_bold_moco Images 60 glm_10B10A_moco_filter3D_ evp alm 10810A_moco_filter3D evp glm_10B10A.evp glm_10B10A_moco.evp gim_10B10A_moco_filter3D.evp t-test 10B10A.evp t-test 10B10A_moco.evp t-test 10B10A_moco_filter3D.evp 5. Successful Calculation – calculation runs in the background and parameter images are displayed in the BOLD Task Card. Patient Applications ystem Options Help  Alpha Images – Lower left 123 BOLD EVALUATION - 2D BOLD EVALUATION - 2D Symphony Quantum FH *1/1/1980. M. 22Y 123 M1/1 /1 980, M. 22Y WAR 2002 BOLD EVALUATION STUDY Exam 9/1 8/2002 STUDY 1 9/18/2002 segment 512:37 PM 63 MA 1 /60 5:12:37 PM 65 MA 141 Upper Palette HotMetal  T-Test – Upper left segment Max. Value 40.95 Upper Range Viewing  Mosaic Images – Upper 30.71 : right segment Upper Low Range 4.00 MF 1.00 Lower Up Range -4.00 Filming TR 4200 0 TP O TE 50.0 TA 00.06 @ FILTERED/MOC SL. 3.00.75 EVV 2170.0 FoV 1152 1152 FMRITTESTAND FILTERED Lower Range 64*64 -19.04 : _64/90 Reference volume for motion correction Peptid2d1_64 /90 Min. Value .40.95 Lower Palette ColdMetal 3D Alpha Value 11.00 Simple Clustering Neuro 3D Anatomical Threshold 0.1 BOLD SIEVENGA MR ALPHA 512'512 BOLD overlay series SP F60.9 11 > 4,00 Waiting for patient registration. 8/4/2014 10:05:22 AM Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 5 Job Aid | BOLD Evaluation – A-Eline Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063679 6. Editing and Saving a Post-processing Protocol - post-processing protocol defines sequence and properties of individual post-processing steps. a. Select post-processing protocol from selections list in Evaluation Controller Dialog b. Select Edit Protocol i. Adapt parameters ii. Save – saves changed protocols (e.g., overwrites protocol selected) iii. Save As – creates a protocol with a different name c. Note: Only Experienced users should edit post-processing protocols Evaluation Controller Dialog X Series No. Description Images act_ep2d_motor_cortex 16 (1) 96 97 act_ep2d_motor_cortex 16 98 act_ep2d_motor_cortex 16 99 act_ep2d_motor_cortex 16 act_ep2d_motor_cortex 16 (2)- BOLD.evp Execute Edit Protocol Delete Series Cancel Help 7. Fuse Anatomical Data with BOLD Data a. Select Applications > BOLD i. Prerequisite: BOLD Task Card must be open prior to loaded functional series into BOLD Evaluation b. Open Patient Browser > select 2D Anatomical data set (e.g., T2_se or T2_dark fluid tra) i. Drag and drop sequence into the BOLD Task Card “Upper Left” segment ii. Scroll through fused images using“dog ears” in Upper Left segment Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 5 Job Aid | BOLD Evaluation – A-Eline Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063679 Patient Applications Edit View Image Tools Scroll System Options Help  Alpha Value – 123 BOLD EVALUATION - 2D Symphony Quantum FH4/13 BOLD EVALUATION - 2D Symphony Quartum Foiata #1/1/1960, M, 22Y Symphony MR 2002B 123 M1M/1980, M, 22Y BOLD EVALUATION STUDY 1 HFS defines degree of 9/18/2002 +LPH STUDY 1 Exam 4:59:44 PM 9/18/2002 16 IMA 27 /36 5:12:37 PM 78 MA 1 /1 Upper Palette transparency of HotMetal Max. Value 40.95 Exam fused functional Upper Range Viewing 30.71 data Upper Low Range  Simple Clustering – 4.00 Lower Up Range MF 1.00 -4.00 Filming suppresses random 10cm MF 1.00 TR 500.0 TE 12.0 TR 4200.0 TA 02:23-2 TP O. TE 50.0 BWV 130.0 SP H36.6 TA 00.08 BW 2170.0 pixels in Alpha MAD SL 3.0/0.75 FoV 230-230 FMRUTTESTAND FILTERED SL 3.0/0.75 FoV 1152 1152 Lower Range 22 144 1925 64.64 -19.04 NO Tra A1FFS Tro 'sc2d1 /70 2 358 epfid2d1_64 /90 W 4095 2048 image Min. Value -40.95 Lower Palette ColdMetal 3D Alpha Value 1.00 Simple Clustering Neuro 3D Anatomical Threshold BOLD GOLD overlay serles 512+512 SP H36.6 H > 4.00 Waiting for patient registration. 8/4/2014 10:32:58 AM c. Save Fused Series i. Select Patient > Save All Alpha As – saves all slice positions and name of new series in Patient Browser ii. Fused Series can be seen in the Viewing Task Card or sent to PACS Patient Applications Edit View Register ... Num 0 Save AS ... Browser ... Num Save All Alpha As .. Close Patient Filming Layout .... Film Task Status ... Film Preview ... Expose Film Task Ctrl+P Copy to Film Sheet Num Enter Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 4 of 5 Job Aid | BOLD Evaluation – A-Eline Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063679 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 5 of 5