BOLD Neuro 3D (A-E Line)

BOLD Neuro 3D (A-E Line)

BOLD Neuro 3D (MR) A to E-line syngo BOLD 3D (MR) evaluation allows post-processing of fMRI data including motion correction, spatial filtering, and statistical evaluation. Results of the evaluation of specific regions of the brain are displayed graphically. 1. From the Patient Bowser > select 3D Anatomical series (e.g., T1 MPRage) a. Select Applications > Neuro3D (MR), and load the appropriate data set into Neuro 3D (MR) Task Card Applications Transfer Report Open Report Tools Mosaic Patient Browser 3D Patient Applications Transfer Edit View Filter Evaluation Sort Options Help Argus Tissue × BOLD BOLD Evaluation Soft Tissue (MR) BREAST - MEAN CURVE [15] gre_field_mapping Composing BOLD NEURO 3D [16]t1_se_tra Mean Curve Local Database . BOLD EVALUATION - 2D HEAD [21] ep2d_bold_moco Perfusion (MR) Scheduler BOLD / DTI / Perfusion [23] EvaSeries_tTest Spectroscopy WIFE/1 Prot/ DVD_READ ASL PERFUSION Neuro 3D (MR) [24] EvaSeries_tTest Tissue 4D (MR) DVD_WRITE ARGUS VF [25] Mean_& t-Maps Ricom///// / 2. Loading Series into Neuro 3D (MR) Task Card a. Select EvalSeries_GLM Functional series i. Select Application > Neuro 3D (MR) icon 4+* b. Select Functional series i. Select Application > Neuro 3D (MR) icon ii. Note: Load MoCo series if motion evalulation is needed Hint Only one series at a time can be loaded into the Neuro 3D (MR) Task  Card Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063682 Job Aid | Insert Title of Job Aid Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063682 3. Neuro 3D (MR) Task Card a. Select Study icon – upper right control area for an overview of series loaded b. Unload a Series i. Study Folder > select Icon next to Series BOLD_TENSOR_ Study  Popup > select Yes to continue unloading series Anatomy confirm Activation Map This operation will unload the Fieldmap images. Do you want to continue? O] BOLD Yes No Help Fieldmap 4. Fusion Mode Icon a. Select Visual > Functional Properties i. Select More/Less button – additional customization options ii. Activation Color Palette – change activation colors iii. Interpolation iv. Clustering Size Visual System Options Help Functional Properties X Activation Color Palette Single Windowing 40.95 40.95 Home Windowing -15.00 -4.00 4.00 15.00 Anatomy Properties Lower ColdMetal Upper HotMetal Anatomy Gallery .. Interpolation Activation Map Filter Functional Properties Activation Map Clustering Size 20 voxels Diffusion Properties. Anatomy Threshold Mask Diffusion Tractography Properties Activation Map 50 626 Fieldmap Properties ... Close Defaul Less << Help 5. Clip Planes a. Show/Hide Clip Planes Icon i. Left Mouse – turns On/Off display of Clip Planes Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 5 Job Aid | Insert Title of Job Aid Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063682 ii. Right Mouse – opens Clip Plane Properties > Select/Deselect Clip Planes Clip Plane Properties x Show Hide Frame Home Close Help b. Move Clip Planes i. Depress left mouse on edge of clip plane (blue or green line) and drag to move BOLD_TENSOF BOLD TENSOR 40.95 -40.95 COMON D+XE 6. VRT a. Enlarge Segment – easier to work with and manipulate VRT image i. Double left mouse – enlarges segment 1x1 ii. Double left mouse again – changes segment to 4x1 b. Rotate VRT i. Left mouse in VRT segment to rotate 3D fused model Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 5 Job Aid | Insert Title of Job Aid Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063682 7. Create MPR Range – create a series of parallel MPR Thick images perpendicular to a selected 2D view in the reference segment a. Select 2D Reference Segment i. Select MPR Range Properties 16 Icon  Enter Distance between images 4.00  Enter Number of Images -4.00  Position slices MPR Range Properties ? X Image Thickness 1.00mm Distance between Images 3.00mm -40.95 Number of Images 19 Anat 50/FM OFFICIus OFF b. Select Create MPR Range Series Icon i. Calculation in Progress window disappears once MPR Range is created Calculation In Progress 54 % completed Cancel c. Select Save MPR Range Series As Icon i. Fused – series saved as they appear in stack segment and saved as RGB images ii. Native (MR) – individual series are saved (e.g., Anatomy, Field Map, Activation Map, Diffusion) iii. Save image(s) in new series > enter Series Name iv. Select OK – images saved to Patient Browser Save MPR Range x Patient BOLD_TENSOR_3 Modality MR Exam date 20080218 Images 199 Series Type . Fused (Secondary Capture) Native (MR) Save image(s) in new series OK Cancel Help Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 4 of 5 Job Aid | Insert Title of Job Aid Effective Date: 02/18/2020 | HOOD/HILS HOOD05162003063682 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 5 of 5