PEPconnect

Build DE Rapid Results with Auto-Archive Recons in syngo.via

Build DE Rapid Results with Auto-Archive Recons in syngo.via Step by Step

Build DE Rapid Results with Auto-Archive Recons in syngo.via Computed Tomography Rapid Results Technology (RRT) enables the automatic post-processing of image data on syngo.via, the results of which can be held on syngo.via for review, or they can be archived automatically to PACS. 1. Log into syngo.via as an Administrator. From the cog icon, select the Configuration Panel > Advanced Visualization tab. ? X Configuration Panel Configuration Panel Administration Portal Client Settings Advanced Visualization Display And Behavior Export Frontier Rapid Results Technology Client-Server Connection Test General Settings Enable automatic preparation and archiving with Rapid Results Technology at syngo. via Available Result Types Configured Results Parallel Ranges Sinus Coronal 3.0mm Radial Ranges Aorta Radial VRT CT Neuro Perfusion Stroke Perfusion Lung CAD CT Neuro Perfusion_New1 Rib Ranges Lung CAD RibRangesDefault CT Dual Energy Configuration 2. Scroll down to find CT Dual Application Profiles Application Classes Energy Configuration, and se- Application Class Body Bone Removal lect the Application Classes Base Application Class Body Bone Removal · Body Bone Removal (Strong) Bone Marrow tab. From the dropdown, se- . BW Tendon Brain Hemorrhage . BRAIN CA VS HEMOR lect the desired Application Application Subclasses Gout . CPPD Class to configure. Hard Plaques Head Bone Removal · Head Bone Removal (Strong) Scan Mode Heart PBV Kidney Stones Liver VNC Visualization Material · BMD iodine OI Properties Automatic Parallel Automatic Definitions . Gallstone Liver VNC test Ranges Radial Range . Liver VNC axial only . VNCa Extremity CT Dual Energy Configuration · VNCa Spine Lung Analysis · Lung Analysis (Dense Lung) Monoenergetic Plus Parallel Range 1 Rho/Z Virtual Unenhanced Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date: 01/15/19 | HOOD/HILS HOOD05162002983573 Job Aid | Insert Title of Job Aid Effective Date: 01/15/19 | HOOD/HILS HOOD05162002983573 3. If needed, a new Application Class can be cre- ated. Click Create New, enter a name, and Create a New Application Class ? X click OK. Name: OK Cancel 4. For each Application Class, up to two different sets of Parallel Ranges can be configured to generate automatically. From the Automatic Parallel Ranges tab, click the checkbox(es) to enable Parallel Range 1 and/or Parallel Range 2, and configure the desired Parallel Range parameters, such as Display Type, Orientation, Slice Thickness and Increment, and from which DE dataset the ranges should be created (e.g. Dataset 1 = Virtual Non Contrast, Da- taset 2 = Gray Scale Iodine Map, Dataset 3 = Fused Color Iodine Map). Click Apply to save the changes. Application Subclasses Liver VNC Scan Mode 80/140KV Visualization Algorithm Preprocessing Automatic Parameters Material Definitions Presets Options ROI Properties Parallel Ranges Automatic Archiving of Thin Slice (Original) Parallel Range 1 Parallel Range 2 Display Type MPR Thick Display Type | MPR Thick Orientation Axial Orientation Coronal Slice Thickness [mm] 3.0 Slice Thickness [mm] 3.0 + Increment [mm] 2.0 + Increment [mm] 2.0 Dataset 1 Dataset 1 Dataset 2 Dataset 2 Dataset 1+2 Dataset 1+2 OK Apply Cancel High Resolution High Resolution Include Reference Image Include Reference Image Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 4 Job Aid | Insert Title of Job Aid Effective Date: 01/15/19 | HOOD/HILS HOOD05162002983573 5. For select Application Classes, one Radial Range can be configured to generate automatical- ly. From the Automatic Radial Ranges tab, click the checkbox to enable Radial Range, and configure the desired Radial Range parameters, such as Display Type, Number of Images, and Angle Between Images). Click Apply to save the changes. Application Subclasses Kidney Stones Scan Mode 80/140KV Visualization Algorithm Material Preprocessing Automatic Parallel Automatic Parameters Definitions Presets Options ROI Properties Ranges Radial Range Automatic Archiving of Radial Range Display Type VRT Number of Images 19 Angle between images [o] 10 High Resolution OK Apply Cancel Include Reference Image Newly-created Applications Classes will now be available in the Scan Protocol Assistant on the scanner for use. Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 4 Job Aid | Insert Title of Job Aid Effective Date: 01/15/19 | HOOD/HILS HOOD05162002983573 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 4 of 4

  • Build DE Rapid Results with Auto-Archive Recons in syngo.via