Cardiac DynaCT for Aortic Valve Guide Procedure Setup
Cardiac DynaCT for Aortic Value Guide Procedure Setup Interventional Radiography: Cardiac Please refer to manual for complete system capability: www.siemenslearningcenter.com 1. Patient Setup: Position patient as far head side as possible Keep all cables away from chest area Place pigtail into aortic root; deep into the cusps Injector filled with contrast: o Options: 33% contrast/67% saline 50% contrast/50% saline 2. System setup and program selection: Best working position for Zeego is Left side 30% rotated Select the 5s untriggered Cardiac program and follow prompts on Assist monitor for 3D spin setup. During Test Phase, ensure that all staff, lines, and equipment are clear of the rotation area. Hook catheter to injector. Purge the line to clear all air from tubing. Hand advance the contrast through the catheter. Set the injector to sync with the system and verify injection parameters with physician: o X-ray delay of 1 second o 15ml/second for 4-6 seconds o If using a Medrad Arterion injector, check for the ISI symbol to confirm injection is controlled by imaging system. SIEMENS siemens.com/healthineers Healthineers . Job Aid | Cardiac DynaCT for Aortic Valve Guide Procedure Setup Effective Date: 09/08/2016 | Quality HOOD0516200293804 o Arm the injector o Please refer to Cardiac DynaCT quickguide for complete injection protocol and rapid pacing suggestions. 3. Scan: Rapid pace, confirm that blood pressure has dropped. Please refer to Cardiac DynaCT quickguide for complete injection protocol and rapid pacing suggestions. Press the acquisition foot pedal or hand switch Contrast will inject for 1 second C-arm will rotate for 5 seconds Stop rapid pacing The data will automatically transfer and reconstruct to the XWP 3D workstation and the Aortic Valve Guide software can be used Siemens Healthineers Services Page 2 of 3 Job Aid | Cardiac DynaCT for Aortic Valve Guide Procedure Setup Effective Date: 09/08/2016 | Quality HOOD0516200293804 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3
- Angiography/Interventional Imaging
- Angiostar