Change Tomo Procedures from Combo to Tomo Only Job Aid
Use the following steps to change procedures from combo acquisition mode to Tomo only acquisition mode with Insight 2D.
How to Change Tomo Procedures from Combo to Tomo only Use the following steps to change procedures from combo acquisition mode to Tomo only acquisi- tion mode with Insight 2D. This process needs to be repeated for ALL tomo procedures and for ALL users if multiple users are configured. 1. Log in as user 2. From the top dropdown menu, select Options→Configuration→Procedure handling I WH AWS - Configuration Panel File Procedure Handling C. WTAWS MoodLight Patient Certificate Screen Saver Transfer C .. Browser Handler WE ? Add Printer Transfer Audit Trail Filming Study Filming Filming Layout Layou ayout Editor Patien Patien Software Viewing Reset Imane Text 3. Select a Tomo procedure Procedure Handling Configuration Procedures EXPOSURE Programs | Projection names List of Procedures Procedure details QC RAW Name MAMMO SCREENING TOMO QC PROCESSED TOMO K K IMPLANTS Examination purpose Screening MAMMO SCREENING W/ CA MAMMO SCREENING TOMO Store procedure as Available for current user only MAMMO DIAGNOSTIC BILAT IA RIA ARIAATIALFFT 4. Click Modify PVS to open the PVS Dialog box Procedures EXPOSURE Programs List of Procedures Procedure details Name MAMMO SCREENING TOMO QC PROCESSED TOMO Examination purpose Screening MAMMO SCREENING W/ CA 588 MAMMO SCREENING TOMO Store procedure as Available for current user only MAMMO DIAGNOSTIC BILAT MAMMO DIAGNOSTIC LEFT Show Procedure Code MAMMO DIAGNOSTIC RIGH Bilateral Mammogram Bilateral Mammogram+Mag Bilateral Mammogram+Spot F Auto Decomp Opcomp R Mammogram L Mammogram R Mammogram+Mag L Mammogram+Mag R Mammogram+Spot Defaut Display Layout L Mammogram+Spot Magnification Autofilming Autoexpose Spot Implant Bilateral Implant+Implant Displaced Bik IP Set Constancy Test Calibration Display Markers Except mag/spot QC-raw QC-processed Modify PVS Bilateral Tomo Bilateral Tomo + 2D Projection View set SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 How to Perform a Wire Locaiization, VC20 Effective Date: 06/28/2021 | HOOD05162003203811 Healthineers Job Aid | How to Change Tomo Procedures from Combo to Tomo only Effective Date: 06/28/2021 | HOOD05162003203811 5. Double click each Projection View (RCC, LCC, etc.) to remove from the Current Projection View Set PVS Dialog 1X Modify PVs Modify PV's Current Projection View set R-CC TOMO L.CC TOMO L-MLO TOMO R-MLO TOMO Acquisition mode Tomo 6. Select the Acquisition Mode→Tomo from the dropdown. PVS Dialog Current Projection View set Acquisition mode Standard 2D Standard 2D Spot Implant Prime Axillary Tail Cleavage Magnification Rolled Inferior Rolled Lateral Tomo Prime+Tomo Magnification Tomo Implant 2D+Tomo Implant 7. Double click on each Projection View (RCC, LCC, etc.) to add to the Current Projection View Set. L-ML L-SPEC R-SPEC R-ML L-MLO L-XCC R-XCC R-MLO L-LM L-XCCL R-XCCL R-LM L-LMO L-XCCM R-XCCM R-LMO L-CC R-CC L-FB R-FB L-SIO R-SIO SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 How to Change Tomo Procedures from Combo to Tomo only |Effective Date: 06/28/2021 | HOOD05162003203811 Healthineers Page 2 of 4 Job Aid | How to Change Tomo Procedures from Combo to Tomo only Effective Date: 06/28/2021 | HOOD05162003203811 8. When all Projection Views are added to the Current Projection View Set, Click Apply and OK- the PVS Dialog box will close. PVS Dialog x Modify PVs Modify PV sequences Current Projection View set R-CC TOMO L-CC TOMO L-MLO TOMO R-MLO TOMO Acquisition mode Tomo Axillary Tail [ Cleavage Implant Displaced r Tangential Rolled Inferior [ Rolled Lateral Rolled Medial Rolled Superior [ Magnification Spot L-ML R-ML L-MLO R-MLO L-LM R-LM L-LMO R-LMO L.CC R-CC L-FB R-FB L-SIO R-SIO Cancel 9. Click Apply Procedures EXPOSURE Programs | Projection names List of Procedures Procedure details QC RAW Name MAMMO SCREENING TOM QC PROCESSED TOMO IMPLANTS Examination purpose Screening MAMMO SCREENING W/ CA MAMMO SCREENING TOMO Store procedure as Available for current user only MAMMO DIAGNOSTIC BILAT MAMMO DIAGNOSTIC LEFT Show Procedure Code MAMMO DIAGNOSTIC RIGH" Bilateral Mammogram Bilateral Mammogram+Mag Bilateral Mammogram+Spot Auto Decomp Opcomp R Mammogram L Mammogram R Mammogram+Mag L Mammogram+Mag R Mammogram+Spot Default Display Layout L Mammogram+Spot Magnification Autofilming Autoexpose Spot Implant Bilateral IP Set Flavor 1 Implant+Implant Displaced Bili Constancy Test Calibration Display Markers Except mag/spot QC-raw QC-processed IQ Bilateral Tomo Projection View se Bilateral Tomo + 2D Bilateral Tomo + 2D PRIME R-CC TOMO PRIME L-CC TOMO PRIME L-MLO TOMO PRIME R-MLO . QC-raw Tomo QC-processed Tomo Rilateral Mammogram . PRIM 10000000000000000000000000000 New CODY Delete et default OK Cancel Apply 10. Select the next Tomo procedure→ complete all steps above. Click Apply after each proceure that is modified. 11. When all procedures have been modified, log out and log in to the next user **This Must be done for all Tomo procedures** **Must log in as each user and complete the steps for each tomo procedure** SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 How to Change Tomo Procedures from Combo to Tomo only |Effective Date: 06/28/2021 | HOOD05162003203811 Healthineers Page 3 of 4 Job Aid | How to Change Tomo Procedures from Combo to Tomo only Effective Date: 06/28/2021 | HOOD05162003203811 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2021 How to Change Tomo Procedures from Combo to Tomo only |Effective Date: 06/28/2021 | HOOD05162003203811 Healthineers Page 4 of 4
- tomo
- combo
- inspiration
- revelation