Cios Select - Cleaning and Disinfection Guide
Cios Select - Cleaning and Disinfection Guide
Cleaning and Disinfection Guide Cios Select Before cleaning or disinfecting the Cios Select, ensure that the system is disconnected from the power supply and switched off. Prior to the examination: Prior to each examination, clean all parts that come into contact with the patient, to prevent contamination of the Cios Select. Make sure that any dust on the housing of the flat detector, the single tank and the C-arm are removed. Cleaning the system parts: Clean the system parts with a damp cloth. For moistening, use water or a lukewarm diluted aqeous solution, consisting of water and a household cleaning agent. Cleaning agents and disinfectants containing chlorine derivatives can discolor cables, but will not negatively impact system functions. Never immerse system parts (except the footswitch) in liquid or autoclave system parts. Cleaning the screen surfaces/TFT displays: The screen surfaces can be cleaned at any time. Clean the monitor screen with a cotton cloth dampened with water. Immediately dry off the monitor screen with a soft cotton cloth. Wipe off contrast agent spots as soon as possible. Disinfection: For the disinfection of surfaces we recommend liquid solutions of common surface disinfectants based on on aldehyde and/or amphoteric surfactants, e.g. Tensodur 103, Kohrsolin, Cidex. Certain substituted phenol-based or chlorine –splitting disinfectants can corrodematerials and are therefore not recommended. SIEMENS siemens.com/healthineers Healthineers Job Aid | Cleaning and Disinfection Guide Cios Select Effective Date: 07/06/2018 | HOOD05162002896281 Only use the recommended cleaning agents and disinfectants. Do not allow any cleaning fluids to enter the openings of the system (e.g. air openings, gap between covers). Observe the Operator Manual of the disinfectant. Some substances contained in disinfectants are known to be hazardous to health. The concentration of such substances in the air must not exceed the legally defined limt. We recommend that you follow the manufacturers’ usage instructions for these products (active ingredient class). The following active ingredient classes may be used to clean and disinfect the Cios Select: Aldehydes, alkylamines, quaternary compounds, guanidine derivatives, peroxide compounds, organic acids, chlorine derivatives, alcohol, benzene, vcommon household dishwashing liquids, detergents. Protection classes/Protection measures: System Component Protection Class Protection Measures X-ray tube assembly IPX3 waterproof protect with sterile cover (Single-tank) Flat detector IPX0 waterproof protect with sterile cover C-arm IPX0 waterproof protect with sterile cover Standard footswitch IPX8 protected against separate from chassis Immersion beyond 1 m before cleaning Hand switches IPX3 dust protected, separate from chassis protected against before cleaning splashing of water Wireless footswitch* IPX8, protected against separate from chassis immersion before beyond 1 m cleaning * Optional Siemens Healthineers Services Page 2 of 3 © Siemens Healthcare GmbH, 2017 Job Aid | Cleaning and Disinfection Guide Cios Select Effective Date: 07/06/2018 | HOOD05162002896281 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warn- ings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH, 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 3 of 3 © Siemens Healthcare GmbH, 2017
- Cios Select - Cleaning and Disinfection Guide