Cios Flow Multifunctional Footswitch (Option)
In this job aid, you will learn about the functions of the multifunctional footswitch. The optional multifunctional footswitch offers the same functions as the standard footswitch, such as radiation release and image storage. Moreover, it provides additional features, such as a mode and save button.
Cios Flow Multifunctional Footswitch (Option) Job Aid Advanced Therapies Mobile C-arms – Cios Flow VA30G The optional multifunctional footswitch offers the same functions as the standard footswitch, such as radiation release and image storage. Moreover, it provides additional features, such as a mode and save button. In this job aid, you will learn about the functions of the multifunctional footswitch. Overview The following image shows the standard configuration of the multifunctional footswitch. Please note that the layout and functionality assigned to the foot pedals can be config- ured in the Service Software, and therefore can deviate from the standard configuration. 4 3 5 @ MODE 2 · MODE 1 6 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2021 | HOOD05162003158388 Healthineers Job Aid | Cios Flow Multifunctional Footswitch (Option) Effective Date: 01/25/2021 | HOOD05162003158388 No. Description No. Description 1 Left pedal 4 Cord Radiation release for the selected operating mode 2 Stirrup 5 MODE button Prevents unintended actuation. Use to re- Selects an operating mode position the footswitch by foot. 3 Save button 6 Right pedal Stores images or scenes Radiation release for fluoroscopy Operation Select an operating mode If necessary, press the MODE button several times to select one of the operating modes: Single im- MODE age, Fluoro, SUB, Road or a video source (depend- ing on the configuration level). . MODE Orb. O The selected operating mode is indicated in the Ang. 0" 0 Examination task card and on the control panel of 00:00:00 17 hixmrass the C-arm system. Barios D not Isel A -8 Nove Mar Chite A confirmation sound acknowledges successful operating mode/video source switchover. You can then release radiation again right away. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2021 | HOOD05162003158388 Healthineers Page 2 of 5 Job Aid | Cios Flow Multifunctional Footswitch (Option) Effective Date: 01/25/2021 | HOOD05162003158388 Release radiation The functionality of the pedals can optionally be changed. The information provided in this document refers to the default settings. Use the right pedal to activate fluoroscopy. Keep the foot pedal pressed during radiation re- . MODE lease. Press the left pedal to activate the currently se- MODE lected operating mode. Exception: If the Fluoro mode is selected, the Sin- . MODE gle Image operating mode is assigned to the left pedal. In this case, keep pressing the pedal until the radiation stops automatically. Store images Press the save button on the multifunctional footswitch. & MODE • Last image hold (LIH): Hold the key for less .MODE than two seconds to save the image last rec- orded. • Last scene hold (LSH): Hold the key for more than two seconds to save the scene last rec- orded. The images are stored in the local database. They are transferred from the left monitor to the right monitor unless the Hold reference function is active. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2021 | HOOD05162003158388 Healthineers Page 3 of 5 Job Aid | Cios Flow Multifunctional Footswitch (Option) Effective Date: 01/25/2021 | HOOD05162003158388 Secure the Footswitch for Transport Ensure that the footswitch is properly secured at the C-arm system when you move the system. To secure the footswitch properly, do the following: 1. Wrap the cable around the stirrup. 2. Then insert the footswitch into the holder at the front of the C-arm system. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2021 | HOOD05162003158388 Healthineers Page 4 of 5 Job Aid | Cios Flow Multifunctional Footswitch (Option) Effective Date: 01/25/2021 | HOOD05162003158388 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/25/2021 | HOOD05162003158388 Healthineers Page 5 of 5
- Cios
- Flow
- footswitch