Cios Flow Multifunctional Wireless Footswitch (Option)
In this job aid, the user will learn about the functions of the multifunctional wireless footswitch.
Cios Flow Multifunctional Wireless Footswitch (Option) Job Aid Advanced Therapies Mobile C-arms – Cios Flow VA30G The optional multifunctional wireless footswitch offers the same functions as the stand- ard footswitch, such as radiation release and image storage. Moreover, it provides addi- tional features, such as a mode and save button. In this job aid, you will learn about the functions of the multifunctional wireless footswitch. Overview The following image shows the standard configuration of the multifunctional wireless footswitch. Please note that the layout and functionality assigned to the foot pedals can be configured in the Service Software, and therefore can deviate from the standard con- figuration. 5 5 4 6 7 ((6ppp) 3 MODE 2 . MODE 1 8 8 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/26/2021 | HOOD05162003158395 Healthineers Job Aid | Cios Flow Multifunctional Wireless Footswitch (Option) Effective Date: 01/26/2021 | HOOD05162003158395 No. Description No. Description 1 Left pedal 5 Rotary knob of battery compart- Radiation release for selected operating ment mode 2 Battery status LED 6 MODE button Changes modes 3 Connection status LED 7 Stirrup Prevents unintended actuation Use to re-position the footswitch by foot 4 Save button 8 Right pedal Stores images or scenes Radiation release for fluoroscopy States of the status LED Subject Modes Battery status LED • Green: Battery full or nearly full Battery capacity • Orange: Battery almost full The battery capacity is also • Orange (flashing): Battery low shown on the left monitor’s status bar. Connection status LED • Green: Connection active Radio link or pairing mode • Orange: No connection active • Orange (flashing): Footswitch not paired • Green and orange alternately flashing: Pairing mode activated Battery status LED + • Orange (both LEDS flashing): Fatal system errors Connection status LED (for example, battery exhausted or memory er- Fatal error or footswitch update ror) • Green and orange (both LEDS alternately flash- ing): Firmware update process running Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/26/2021 | HOOD05162003158395 Healthineers Page 2 of 7 Job Aid | Cios Flow Multifunctional Wireless Footswitch (Option) Effective Date: 01/26/2021 | HOOD05162003158395 Operation Switch on the wireless footswitch Take the wireless multifunctional footswitch out of the footswitch holder. Place it horizontally on the floor. This will switch on the footswitch automatically. Swivel the stirrup into the upright position until it locks. The footswitch is now ready to use. The footswitch automatically switches to standby mode if it is not used for a certain peri- od of time. Activate it again by pressing any button or pedal. Select an operating mode If necessary, press the MODE button several times to se- lect one of the operating modes: Single image, Fluoro, SUB, Road or a video source (depending on the available .MODE operating modes). Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/26/2021 | HOOD05162003158395 Healthineers Page 3 of 7 Job Aid | Cios Flow Multifunctional Wireless Footswitch (Option) Effective Date: 01/26/2021 | HOOD05162003158395 The selected operating mode is indicated in the Examina- Ang. 0 tion task card and on the control panel of the C-arm sys- 00:00:00 17 tem. hixmriss A confirmation sound acknowledges successful operating mode/video source switchover. You can release radiation Die A -B again right away. Release radiation The functionality of the pedals can optionally be changed. The information provided in this document refers to the default settings. Use the right pedal to activate fluoroscopy. ¿ MODE Keep the foot pedal pressed during radiation release. MODE Press the left pedal to activate the currently selected op- erating mode. () MODE Exception: If fluoroscopy (CFC) mode is selected, the left .MODE pedal is assigned as Single Image operating mode. In this case, keep pressing the pedal until the radiation stops automatically. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/26/2021 | HOOD05162003158395 Healthineers Page 4 of 7 Job Aid | Cios Flow Multifunctional Wireless Footswitch (Option) Effective Date: 01/26/2021 | HOOD05162003158395 Store images Press the save button on the multifunctional footswitch. COMODE • Last image hold (LIH): Hold the key for less than two seconds to save the image last recorded. MODE • Last scene hold (LSH): Hold the key for more than two seconds to save the scene last recorded. The images are stored in the local database. They are transferred from the left monitor to the right monitor unless the Hold reference function is active. Replace the batteries 1. To open the battery compartment, lightly press in the knob and turn it counterclockwise. 2. Remove the batteries. 3. Insert new batteries (LR14) into the footswitch. + HI 4. To close the battery compartment, insert the knob into the depressions. Press lightly and turn it until it clicks into place. O Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/26/2021 | HOOD05162003158395 Healthineers Page 5 of 7 Job Aid | Cios Flow Multifunctional Wireless Footswitch (Option) Effective Date: 01/26/2021 | HOOD05162003158395 Secure the Footswitch for Transport For secure storage and transportation of the footswitch, insert the footswitch into the holder on the front of the C-arm system. Ensure that the colored symbols on the footswitch are lined up with the ones on the holder to avoid inserting the wrong footswitch. The following colored symbols are used for unique allocation of the footswitch to the holder: Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/26/2021 | HOOD05162003158395 Healthineers Page 6 of 7 Job Aid | Cios Flow Multifunctional Wireless Footswitch (Option) Effective Date: 01/26/2021 | HOOD05162003158395 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and c autions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be comme rcially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/26/2021 | HOOD05162003158395 Healthineers Page 7 of 7
- CIios Flow
- Footswitch