Cios Fusion - System Start Up
This Job Aid explains what the user needs to consider before starting the system and which steps need to be performed for the system start up.
Cios Fusion: System Start-up Job Aid Advanced Therapies – Cios Fusion This Job Aid explains what you need to consider before starting the system and which steps need to be performed for the system start up. Before connecting the C-arm system with other components, please ensure that plugs and connectors are clean and dry. Do not use damaged cables and plugs. Make sure that the C-arm system brakes are locked using the steering lever. The red indicator shows that the brakes are locked (see image below). Steering Lever with Red Indicator Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 5 Mar 2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2021 | HOOD05162003156877 Healthineers Job Aid | System Start-up Effective Date: 01/15/2021 | HOOD05162003156877 To start the system, perform the following steps: 1. Connect the C-arm system to the monitor trolley by plugging the central plug into the socket on the left side of the C-arm system. The switch must be in vertical position. Turn the central plug switch to the right until it locks into place. You can hear a clicking sound. Central Plug SIEMENS 2. On the C-arm system, plug the footswitch cable into the socket labeled with the footswitch symbol. Socket for Footswitch Cable O SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date 01/15/2021 | HOOD05162003156877 Healthineers Page 2 of 4 Job Aid | System Start-up Effective Date: 01/15/2021 | HOOD05162003156877 3. To establish the power connection of the system, plug the monitor trolley power plug into an appropriate socket to establish the power connection of the system. 4. Switch the system on by pressing the ON button on the monitor trolley. OFF ON SONY 5. The system automatically runs a self-test. On the control panel, all LEDs light up for approximately two seconds as a function test and then switch off automatically.Do not press any key during the self-test. An audible signal sounds while the system starts up. During start-up, a start-up screen is displayed on the left monitor stating the current software version of your system. SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date 01/15/2021 | HOOD05162003156877 Healthineers Page 3 of 4 Job Aid | System Start-up Effective Date: 01/15/2021 | HOOD05162003156877 Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and sha ll by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific c ountry is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date 01/15/2021 | HOOD05162003156877 Healthineers Page 4 of 4
- Cios Fusion