Cios Fusion - Using Reference Images
This job aid explains how images can be transferred during or after radiation release from the left to the right monitor using different functions, and which consequences these functions have.
Cios Fusion: Using Reference Images Job Aid Advanced Therapies Mobile C-arms – Cios Fusion Live images are displayed on the left monitor. Selected images used, for example, for comparisons can be displayed on the right monitor. This job aid explains how images can be transferred during or after radiation release from the left to the right monitor using different functions, and which consequences these functions have. Transferring Images when Saving When saving, an image or scene is transferred manually or automatically from the left to the right monitor. 1. During or after radiation, save the image manually by selecting Store. The displayed image on the left monitor is saved and transferred to the right monitor. 2D Orb.0º Ang.0º Store U: 0º not flipped position 20 68 uGym2 KV 00:00:10 17 hh:mm:ss mA * Collimator Laser Reset timer Series #: Image #: Fluoro Single mage Rotate Live graph Zoom Pan Measure Flip overlay Shutter Annotate Reset all Sub Road DCM REF + Brightness Overview Hold Cine Contrast reference replay Previous Next Medium Auto Dose Metal Tech lock A + B correction Image enhance Transfer Store Store cine Print Export to USB Mag 0 15 p/s Magnify Motion Noise filter Pulse rate PREPARATION PROCESSING EXTERNAL Close pat. Keyboard If the function Automatic save is active, the image is saved and transferred automatically after radiation ends. SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 01/15/2021 | HOOD05162003156882 Job Aid | Cios Fusion: Using Reference Images Effective Date: 01/15/2021 | HOOD05162003156882 Please note: It is also possible to store images with the hand switch or multifunc- tional footswitch. 2. If you want to save a scene and display it at the right monitor, save the scene manually by selecting Store cine. 2D Orb. 0º Store U: 0º not flipped Ang.0º position 20 68 uGym2 kV 00:00:10 17 hh:mm:ss mA * Collimator Laser Reset timer Series #: Image #: Fluoro Single R RJA mage Rotate Live graph Zoom Pan Measure Flip overlay Shutter Annotate Reset all Sub Road DCM REF + Brightness Overview Hold Cine Contrast reference replay Previous Next Medium Auto Tech lock A + B Dose Metal correction Image Export to enhance Transfer Store Store cine Print USB Mag 0 15 p/s Magnify Motion Noise filter Pulse rate PREPARATION PROCESSING EXTERNAL Close pat. Keyboard If the function Automatic save is active, the scene is saved and transferred to the right monitor after radiation ends. Please note: It is also possible to store scenes with the hand switch or multifunctional footswitch. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2021 | HOOD05162003156882 Healthineers Page 2 of 6 Job Aid | Cios Fusion: Using Reference Images Effective Date: 01/15/2021 | HOOD05162003156882 Using the Transfer-A-to-B Function By using the transfer-A-to-B function, you can transfer an image to the right monitor during or after radiation. To do that, select Transfer. 2D Orb. 0º not flipped Ang.0º Store O: 0º position 20 68 HGym2 KV 00:00:10 17 hh:mm:ss mA IIII * Collimator Laser Reset timer Series #: Image #: Fluoro Single XYZ image Rotate Live graph Zoom Pan Measure Flip overlay Shutter Annotate Reset all Sub Road DCM REF - + Brightness Contrast Overview Hold Cine reference replay Previous Next Medium Auto Dose Metal A +B correction Tech lock Image Transfer Store Store cine Print Export to enhance USB Mag 0 15 p/s Magnify Motion Noise filter Pulse rate PREPARATION PROCESSING EXTERNAL Close pat. Keyboard Please note: When using this function, the transferred image will NOT be saved. It will be lost permanently when it is overwritten with another image. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2021 | HOOD05162003156882 Healthineers Page 3 of 6 Job Aid | Cios Fusion: Using Reference Images Effective Date: 01/15/2021 | HOOD05162003156882 Holding a Reference Image The hold-reference function allows you to select a particular image and to permanently display it as a reference image on the right monitor. 1. Select Hold reference. Now, the display on the right monitor holds the image permanently. The transfer of additional images and scrolling to other images is disabled on the right monitor. 2D Orb.0º U: 0 not flipped Ang.0º Store position 20 68 HGym2 KV 00:00:10 17 hh:mm:ss mA * Collimator Laser Reset timer Series #: Image #: Fluoro Single R RA XYZ image Rotate Live graph Zoom Pan Measure Flip overlay Shutter Annotate Reset all Sub Road DCM REF + Brightness Contrast Overview Hold Cine reference replay Previous Next Medium Auto Dose Metal Tech lock A + B correction Image enhance Transfer Store Store cine Print Export to USB Mag 0 15 p/s Magnify Motion Noise filter Pulse rate PREPARATION PROCESSING EXTERNAL Close pat. Keyboard 2. Select Hold reference again to cancel the hold-reference function. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2021 | HOOD05162003156882 Healthineers Page 4 of 6 Job Aid | Cios Fusion: Using Reference Images Effective Date: 01/15/2021 | HOOD05162003156882 Please note: The hold-reference function is automatically cancelled when switching to the image overview. It is reestablished, once the image overview display is closed. 2D Orb.0º Ang.0º Store U: 0º not flipped position 20 68 uGym2 kV 00:00:10 17 hh:mm:ss mA * Collimator Laser Reset timer Series #: Image #: Fluoro Single XYZ image Rotate Live graph Zoom Pan Measure Flip overlay Shutter Annotate Reset all Sub Road DCM REF + Brightness Hold Cine Contrast Overview reference replay Previous Next Medium Auto Dose Metal A +B correction Tech lock Image enhance Transfer Store Store cine Print Export to USB Mag 0 15 p/s Magnify Motion Noise filter Pulse rate PREPARATION PROCESSING EXTERNAL Close pat. Keyboard Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2021 | HOOD05162003156882 Healthineers Page 5 of 6 Job Aid | Cios Fusion: Using Reference Images Effective Date: 01/15/2021 | HOOD05162003156882 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 01/15/2021 | HOOD05162003156882 Healthineers Page 6 of 6
- Cios Fusion
- Reference Images