Cleaning the Atellica® CH Analyzer Exterior Covers and Plates Job Aid Version 1.25 and Below

This job aid provides instructions on how to perform the as needed maintenance task of cleaning the Atellica® CH Analyzer exterior covers and plates.

Atellica® CH Analyzer SIEMENS Cleaning CH Analyzer Exterior, Plates, Guard, and Shields Job Aid Healthineers 1. Unlock and open the CH analyzer front and back covers: SIEMENS Healthineers Atellica Solution Version 1.14.0.2983003 SP00107 A. On the Command bar, select System > Status System A Samples Inventory Calibration ac Patient Orders Worklist Maintenance Setup Status Logs Operator Diagnostics About B. Select the CH Analyzer System VMM SH CH B IM C. Select the stop or pause button Standby Off Standby Off D. Select the appropriate button in the software to unlock Alert Category Time Capabilities the front or the back cover E. Lift open the front and back covers 2. Clean the following components with lint-free tissues or Cor C PCC gauze saturated with a 10% bleach solution: G ➢ Exterior covers Front Cover D Back Cover ➢ System fluids tray ➢ Manual reagent load station ? PEP LabManager OXS Tuesday, July 10, 2018 11:27:30 AM ➢ System plates, guard, and shields Note: The lock glyph indicates whether the cover is locked or unlocked. When unlocked, the cover automatically re-locks unless the operator opens the cover within 30 seconds. *This procedure is continued on the next slide. 1 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020 Atellica® CH Analyzer SIEMENS Cleaning CH Analyzer Exterior, Plates, Guard, and Shields Job Aid Healthineers 3. Rinse the components with lint-free tissues or gauze saturated with special reagent water 4. Dry the components with lint-free tissues or gauze 5. Close the CH front and back covers 6. Start the CH by selecting the Resume icon on the CH System Status screen Note: Do not touch the cannulas in the keyed areas at the bottom of the system fluids drawer. The cannulas can puncture skin. 2 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020 SIEMENS Healthineers Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Atellica, and all associated marks are trademarks of Siemens Healthcare Diagnostics Inc. or its affiliates. All other trademarks and brands are the property of their respective owners. Product availability varies by country and is subject to varying regulatory requirements. Please contact your local representative for availability. Copyright © Siemens Healthcare GmbH 2020 Global Siemens Healthineers Headquarters Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84 0 siemens.com/healthineers 3 Template Effective Date: 05/27/2019 | HOOD05162003010284 Effective Date: 24-SEP-2020 | HOOD05162003126734 Unrestricted © Siemens Healthcare GmbH, 2020

  • attelica
  • attellica
  • atelica