PEPconnect

CLINITEK® AUWi PRO™ System Overview Video

This video provides an overview of the CLINITEK® AUWi PRO™ System.

Welcome to the clinic tech. A UW I pro system. This program is designed to provide you with a full understanding of the features and benefits of Siemens healthcare diagnostics. Integrated your analysis workstation. The clinic Tech A UW I Pro system is essentially two analyzers working together as a team of fully automated urine chemistry analyzer and a fully automated urine sediment analyzer. Samples are automatically and intelligently routed from one to the other using a unique sample transport assembly. The clinic tech au WI PRO system coordinates the entire operation by using a dedicated computer utilizing specialized rules based software. The result, an automated high throughput. Your analysis testing solution that provides unattended operation that's reliable. Walk away testing from start to finish. As the saying goes, the whole is greater than the sum of its parts. Let's take a closer look at some of the parts 1st, then tour the entire system as a whole. The innovative clinic tech Novice Analyzer is a fully automated benchtop instrument designed for high volume urinalysis testing. Using Siemens proven technology in dry pad urine chemistry, the clinic tech Novice Analyzer offers improved detection of bilirubin, blood, ketone glucose, leukocyte nitrate, protein and eurobowl innogen by taking into account the color of the urine when evaluating the reagent pad result. The color of the urine. Is measured and subtracted from the color of the reacted reagent pad to compensate for non specific color changes of the pad. Simple to use, offering a full spectrum of tests and a throughput of up to 240 samples per hour, the clinic tech Novus Analyzer streamlines workflow simplifies routine. Your analysis and stat testing, and delivers consistent high quality results even during peak periods. The latest generation in automated urine sediment analysis. This is Max U F-1000I urine cell analyzer builds upon the proven track record of its predecessors with its enhanced bacteria, detection mode and anti carryover function, EU F-1000I improves discrimination of formed elements. Two trusted technologies are combined on a single platform for true Walk away. Urine, chemistry, testing and sentiment analysis controlled by the clinic. Tech Au WI Pro system. The track transport system automatically moves samples from the rack sample loading area. The input queue to the clinic Tech Novice Analyzer, then to EU F-1000I system and finally to the rack sample delivery area or the output queue. The clinic tech au WI prosystem WAM is a specialized rules based customer defined software designed to manage the analyzers an the transport system and collect data for analysis and reporting. Now let's take a look at the entire process from beginning to end. First, a laboratory and loads barcoded samples into the rack sample loading area. Each rack holds up to 10 sample tubes and the system holds a maximum of 10 racks for a total of 100 specimens. The system can perform up to 80 tests per hour. The operator simply pushes the start button, and the system takes over. The operator is now free to leave, stay, or return later to load more racks of samples into the system. For continuous operation. Once the operator pushes the start button, the initial rack of samples advances into place and is transported to the clinic. Tech novas urine chemistry analyzer. The barcode is scanned to verify the identity of the sample. Next, the automated pipette positions itself. The built-in liquid level sensing allows the pipette to adjust automatically to virtually any sample volume and reduces sample preparation time. The sample is then drawn into the clinic tech nervous analyzer for analysis. Using Siemens proven dry pad reagent technology minimally 9 chemistries, plus specific gravity, color and clarity are assessed automatically. Each test set is analyzed in approximately 15 seconds. The pipette an SG well are rinsed between each sample. Our unique and easy to use reagent cassettes ensure maximum productivity and standardized testing in busy labs. The cassettes simplify, Analyzer operation, maintenance and cleaning. Each cassette holds 450 test sets. The proven test pads ensure quality results with excellent sensitivity and specificity, and the cassette format eliminates the need to Orient traditional urinalysis test strips. Simply pop in a cassette and feel confident of the results. Test results go directly to the your analysis WAM workstation. If results are positive, the workstation flags the sample for appropriate additional testing at EU F-1000I. If negative, the workstation instructs EU F-1000I to skip that particular sample. When the rack arrives. When all samples in the rack have been tested, it is routed to EU F-1000I urine cell analyzer. Here several barcodes are reviewed. An matched with workflow instructions forwarded from the workstation. EU F-1000 died pipette mixes the sample thoroughly to distribute sediment evenly before withdrawing a sample for testing, eliminating the need for pre analytical processing such as centrifuging. Once inside the system, the sample is split into two different channels in the sediment channel. The sample is heated to 35 degrees Celsius. To remove any amorphous urates and then aspirated into the flow cell for analysis. In the bacteria channel, the sample was heated to 40 degrees Celsius to suppress non specific staining of particles other than bacteria. EU F-1000I pipette is then rinsed between each sample. Flow cytometry cluster analysis provides automatic classification. An enumeration of formed elements. EU F-1000I is a high throughput analyzer that provides unattended operation and identifies 10 urine parameters, five of which are enumerated and the rest are flagged. The entire process from track loading through urine chemistry analysis and urine sediment analysis is managed by the specialized urinalysis WAM software driven by a powerful yet flexible rules engine. The clinic Tech, a UW ipro system not only intelligently manage is workflow but also provides sophisticated reporting that incorporates results from both analyzers. Specimen management rules are designed to determine when a sample should be tested on EU F-1000I based upon one or more results from the clinic. Tech Novus Analyzer, for example. If a laboratory protocol states that when blood leukocytes, nitrite, or protein results are positive on a clinic tech Novus, then the system can be set up to order. A urine microscopy test on EU F-1000I specimen management rules eliminate the need to manually review each clinic tech novas result. After the last sample in the rack is tested by EU. F-1000 die. The entire rack is transported to the output queue. We've now reached the end of our tour of the clinic Tech, a UW ipro system, the clinic Tech a UW I Pro system is remarkably easy to use, easy to learn and easy to maintain, one that directly addresses the problems that so many laboratory's face.

SIE SIEMENS SIEMENS Sediment UF-1000i SIEMENS Bacteria SIEMENS CLINITEK@ AUWiTM The Process CLINITEK Novus• UF-1000i Components Enumerated 000i Comnponents System Leukocytes Bilirubin WBC Ketones SIEMENS Overview PRO System* WBC UF-1000i sysme svsme Blood sysme Protein UF-1000i @ 2015 Siemens Healthcare Diagnostics, Inc. sysme Squamous Epithelial Cells SIEMENS Blood pH UF-1000i Ketones Ketone Caystals. Caystals CLINITEK UF-1000i UF-1000i CLINITEK 10 Nitrite Glucose All rights reserved. Bacteria Urinalysis Cassette CLINITEK UF-1000i Leukocytes Bilirubin CLINITEK Novus• Leukocyte CLINITEK' AUWi"•• PRO system, CLINITEK Automated Urine CLINITEK@ AUWi"•' PRO System, CLINITEK Automated urine PRO System, CLINITEK Automated Urine UF-1000i Chemistry Analyzer, Sysmex UF-1000i•' Urine Cell Analyzer Chemistry Analyzer, Sysmex IJF-1000i"•' Urine Cell Analyzer IVD Nitrite UF-1000i Occult Blood and all associated marks are trademarks of Siemens Healthcare Flagged 10634643 Diagnostics Inc. or its affiliates. All other trademarks and brands Protein Glucose are the property of their respective owners. Product availability Pathological Casts origin: US USA Origin: US may vary from country to country and is subject to varying SN3W31S Urobilinogen Siemens UF-1000i regulatory requirements. Please contact your local representative Small Round Cells CLINITEK Novus• for availability. Yeast Like Cells Clarity CLINITEK Novus *Product is available for sale in U.S. and Canada only. CLINITEK Novus• Color K0004121 CLINITEK K0004121 CLINITEK Novus• Sperm Specific Gravity Novus 2012/12