CLINITEK Status®+ System Urinalysis Strip Test Online Training
Perform patient testing. Obtain semi-quanitiative results for a variety of test parameters using urinalysis test strips. This clinical laboratory training qualifies for continuing education units (CEU).
Welcome to the CLINITEK Status® Portfolio Urinalysis Strip Test Online Training course. Performing urinalysis provides physicians with valuable information to help detect metabolic and kidney disorders and diagnose many other medical conditions. Several different Siemens urinalysis strips can be used with this analyzer. Urinalysis test strips allow technicians to perform a single test and obtain semi-quantitative results for a variety of test parameters. Note: This course includes information on Options and Functions in the system which may require security approval from your facility in order to access. Select Next to continue. Identify how to delete records from instrument memory (Option must be enabled on analyzer; Operator must have required security access.) Identify how to recall stored results Identify products approved for use on the CLINITEK Status®+ Analyzer Identify the steps to run patient test strips Upon successful completion of this course, you will be able to: Select Next to continue. Congratulations. You have completed the CLINITEK Status® Portfolio Urinalysis Strip Test Online Training course. In this course, you have learned how to: Identify the steps to run patient test strips Urinalysis test strips allow nurses and technicians to perform a single test and obtain semi-quantitative results for a variety of test parameters. Test Modes: Quick Test: The system does not require the operator to enter data prior to starting the analysis. Quick test is the default setting. Full Test: The system prompts the operator to enter operator name, patient name, patient ID, and sample appearance prior to starting the analysis. Custom Setup: Allows each facility to customize which data to enter prior to starting the analysis. Test Types: Strip Test Verify that the test table insert is positioned with the reagent strip holder facing upward. From the Select Ready screen, touch Strip Test to access the Prepare Test screen which will prompt you through the preparation steps that must be completed within 8 seconds. Caution: Wear personal protective equipment. Use universal precautions when working with biohazardous materials. Press the START button then dip the reagent strip into the sample, wetting all the pads. Be careful not to dip the automatic identification band or color band into the urine sample. Remove the strip immediately from the sample by dragging the edge against the side of the sample container. Touch the edge of the strip against a paper towel to blot any excess urine. With the test pads facing up, place the reagent strip in the channel of the table and slide it to the end. At the end of the 8 second countdown, the analyzer automatically pulls in the test table and performs an automatic calibration. Once the automatic calibration is completed, the screen displays a countdown of the time remaining in analyzing strip test results. When analysis is completed, the test strip is ejected and the results can be reviewed on screen or on a printout. Test results remain on screen for 2 minutes. After that time, the display returns to the main Select menu. Touch Done to complete the test and return to the main Select screen. Remove the used test strip from the analyzer. Dispose of the test strip and report results according to the procedures specified at your facility. Identify products approved for use on the CLINITEK Status®+ Analyzer The CLINITEK Status®+ Analyzer uses only Siemens Healthcare Diagnostics products, which include: Siemens Healthcare Diagnostics test strips: chemically impregnated reagent strips that allow technicians to perform a single test and obtain semi-quantitative results for a number of different test parameters. Identify how to recall stored results The CLINITEK Status® platform offers expanded onboard memory storage for patient results that are recalled easily for improved data management. The CLINITEK Status® Connect system also stores quality control results. The CLINITEK Status® Connect Platform stores up to 950 patient test results in the onboard memory. When the limit of 950 has been reached, the oldest test will be deleted from the analyzer. Deleted information cannot be retrieved from the analyzer. The CLINITEK Status® Connect System can store 200 QC results in the on-board memory. As there is no QC functionality on the CLINITEK Status®+ Analyzer, QC results must be tracked manually. Identify how to delete records from instrument memory Patient and QC records stored on the analyzer can be deleted permanently from instrument memory. Prior to deleting test results, be sure that the loss of the test results is acceptable. If the test results have not been sent to a host computer or printer, it is recommended that these tasks are performed before deleting the results as the system erases the results from the database and can no longer be accessed or recalled. Records cannot be deleted on an individual basis. Data stored on an LIS will not be deleted. Select Next to continue. Test modes: Quick Test: The system does not require the operator to enter data prior to starting the analysis. Quick test is the default setting. Full Test: The system prompts the operator to enter operator name, patient name, patient ID, and sample appearance prior to starting the analysis. Custom Setup: Allows each facility to customize which data to enter prior to starting the analysis. Quick Strip Tests Learn how to run a Quick Strip Test. Select the play arrow to begin the video. When complete, select the X in the upper-right corner to close the window and continue. Urinalysis Tests and Disease States Learn more about the use of urinalysis strip testing to diagnose medical conditions. Urinalysis test strips allow technicians to perform a single test and obtain results for a number of different test parameters. Physicians use these tests to help detect metabolic and kidney disorders and diagnose many other medical conditions. Disease Test Urinary Tract Infection Leukocyte Nitrate Kidney Stones, Bladder Cancer pH Occult blood Kidney Disease Protein Leukocyte Esterase Blood Albumin-to-Creatinine Ratio Protein-to-Creatinine Ratio Diabetes, Gestational Diabetes, Eating Disorders Glucose Ketones Liver Disease Bilirubin Urobilinogen When complete, select the X in the upper-right corner to close the window and continue. Full Strip Test Learn how to run a Full Strip Test. Select the play arrow to begin the video. When complete, select the X in the upper-right corner to close the window and continue. Après la collecte et le mélange, l'échantillon est prêt pour l'analyse. Dans cette section, vous apprendrez comment effectuer l'analyse de l'échantillon sur le système RAPIDPoint®. The CLINITEK Status®+ Analyzer uses Siemens Healthcare Diagnostics test strips to perform a single test and obtain semi-quantitative results for a number of different test parameters, such as: Albumin Albumin-to-Creatinine Ratio Bilirubin Blood Creatinine Glucose Ketones Leukocyte (white blood cells) Nitrites Protein pH Protein-to-Creatinine Ratio Specific gravity Urobilinogen Note: The CLINITEK Status®+ Analyzer uses Siemens Healthcare Diagnostics Test Strips that have been validated for use on the system and prevents the use of non-validated test strips. Siemens Healthcare Diagnostics Products Learn more about products approved for use. Products approved for use on the CLINITEK Status®+ Analyzer are shown below. Note: Not all test strips are available in all markets. Urinalysis Test Strips Kidney Disease Portfolio Control Reagents Multistix® 10 SG Multistix® 8 SG Multistix® 7 SG Multistix® 5 SG Multistix® SG Multistix® GP N-Multistix® SG N-Multistix® SG L Uro-Hemacombistix® SG L Uro-Hemacombistix® Hemacombistix® Uristix® Uristix® 4 Labstix® SG N-Neostix® Uro-Uristix® Combistix® SG CLINITEK® Microalbumin 2 strip CLINITEK® Microalbumin 9 Multistix® PRO 10SL Chek-Stix® Urinalysis Control Strips (Positive) Chek-Stix® Combo Pak (Positive/Negative) When complete, select the X in the upper-right corner to close the window and continue. When used as a standalone or in conjunction with the Connector Platform, the CLINITEK Status®+ Analyzer, stores up to 950 patient test results in the on-board memory. When the limit of 950 has been reached, the oldest test will be deleted from the analyzer. Deleted information cannot be retrieved from the analyzer. Note: The CLINITEK Status Connect System can store 200 QC results in the on-board memory. As there is no QC functionality on the CLINITEK Status®+ Analyzer, QC results must be tracked manually. Recall Stored Results Learn how to recall stored results. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90006146/simCSPlusRecallResults_9/simCSPlusRecallResults_9.swfHTML5 File:/content/generator/Course_90006146/simCSPlusRecallResults_9/index.htmlPDF File: Patient and QC records stored on the analyzer can be deleted permanently from instrument memory. Prior to deleting test results, be sure that the loss of the test results is acceptable. If the test results have not been sent to a host computer or printer, it is recommended that these tasks are performed before deleting the results as the system erases the results from the database and can no longer be accessed or recalled. Records cannot be deleted on an individual basis. Data stored on an LIS will not be deleted. Reminder: The CLINITEK Status®+ Analyzer stores QC records as patient tests. Note: This action can be performed only if the function is enabled on the analyzer and the authorization is permitted by your facility. Deleting Stored Records Learn how to delete stored records. Checklist TitleChecklist TypeChecklist ContentSelect ReadyHTML Select each check box to learn more about deleting stored records. On the Select Ready screen, click the Recall Results Button. Recall OptionsHTML On the Recall Options screen, use the down arrow to highlight the Delete Records option then click Select. This selection will be greyed out if this option is not enabled on your analyzer. Delete RecordsHTML On the Delete Records screen, select Yes to delete all records and return to the Select Ready screen or select NO to return to the Recall Options screen. When complete, select the X in the upper-right corner to close the window and continue.
- clini
- connect
- +
- plus
- UA
- patient test strips
- recall stored results
- delete records
- clinical laboratory training