Performing a Quick CLINITEST hCG Cassette Test Video
This video provides instructions on how to properly run a quick CLINITEST® hCG cassette test on your CLINITEK Status®+ Analyzer, including printing results.
A quick test is a convenient way to run a test on the analyzer without having to enter additional data such as operator ID and patient information for this demonstration will run an H CG test. Begin by bringing the cassette test and patient sample to room temperature prior to testing. Verified that the test table insert is in position for a cassette test. From the main select screen touch cassette, test to access the test type screen. Select the clinic test H CG cassette test. Remove the test cassette from the foil package and place it onto the test table. Touch the start button to access the Prepare test screen. Once start his breast, you have 8 seconds to prepare the test. Fill the pipette included with the cassette with urine. Add the entire contents of the pipette into the sample well of the test cassette. Do not add the contents from the overflow chamber. At the end of the countdown, the analyzer pulls in the test table automatically. An automatic calibration is performed each time a test is run. Be careful not to push or bump the test table while the analyzer is calibrating. Once calibration is completed, the screen displays the remaining time for result analysis. Once analysis is completed, the instrument ejects the table and cassette. If the analyzer is set up to print automatically, the printing screen appears until the printout is completed. The result screen displays the test results if the print option has not been enabled and a copy is required, press print to manually obtain one. Touch done, then the back Arrow to return to the main select screen. Remove the use cassette from the instrument. Dispose of the cassette and report the results according to the standard procedures of your facility.
S emens Cl initek Statuse Results Select Test Type Prepare Test Calibrating Analyzing Print Ser i al Number : Cllliltest@s) hCG Please wait In ro ress In proqress lest sequence numnber: 001 1 Test sequence nutllnber: 001 1 Test sequence nutJ1nber: 001 1 Ready Please watt Please Wdlt Please wait In prooress In progress hCG Cliniteste hCG Clinitest@ hCG hCG hCG. . hCG .. hCG . Negative Clinitek Status@ is Calibrating Instrument Select type of cassette Recall Results Help Printing data Place cassette on 1. Draw sample into pipette Pat ient Name: Set U test table and touch 2. Add sample to sample well Test date Test 10-13-2009 1 0-1 3-2009 1 3-2009 0-13-2009 SAPA SMITH SARA SMITH Time 14:10 Patient ID: Pat ient Name: 128002 Clinitest@ hCG Cassette Test strip Test Strip Test Print Test date 00:08 04:47 04:43 10-14-2009 START Time Operator Clinitest@ hCG 128002 hCG Done Test number cassette Running hCG Negat ive Quick Cassette Tests
- Quick Cassette Test
- CLINITEST hCG
- hCG cassette
- operator
- patient name
- patient ID
- video
- remove cassette