Updating Instrument Settings Video

This video provides instructions on how to update the instrument settings on your CLINITEK Status®+ Analyzer, including enabling the connectivity platform and changing the units displayed on the system.

While the startup wizard sets up functions to get started on the analyzer, you may need to customize those settings to meet the requirements of your workplace. To begin, click instrument setup. The instrument settings screens control the way the analyzer operates and displays information. Click select. The results format option is used to determine how test results will be displayed and printed. Click the select button. Unit selection options include conventional standard, international and Nordic, the Plus System option is enabled when your facility requires results shown with the plus symbol rather than in clinical units. Click next to continue. Enabling the mark positive results option will generate an* next to any positive results on the display on a printout, and when the data is transferred to a host computer. You can also enable or disable the storing of the instrument serial number in patient records. Click done to continue. Highlight system settings, then click select. On this screen you can set preferences for the printer and power. Click next to continue. You can also set sound preferences. Click done to return to the instrument settings screen. The display contrast screen is used to adjust the screen display to suit the work area where the analyzer is being operated. Click select to continue. The next setting we will review is connectivity, click select. When using the clinic tech Status Connect system, you will need to enable the connectivity platform. You will also need to enable the platform when using system features such as the barcode reader or quality control prompts. If you are using the analyzer without the connector, leave the setting as disabled using the enabled setting without a connector may prevent communication with an external system when allow results to be sent to a PC is enabled, the system automatically sends knew an recalled test reports to a host computer or LIS. Leave the option as disabled if your facility does not use this feature, click next to continue. This screen is used to set a type of connection, wireless, wired or serial. Once the type of connection is selected, the settings can be edited according to the requirements of your facility. Click done to continue. Highlight your analysis test settings, then click select. The your analysis test screen displays a scrollable list of test strips which can be used with a clinic tech status plus analyzer. Use the scroll bars to select the test strip type used in your facility. The Siemens test strips with auto Check will automatically identify the test strip type. Click the button for edited reported chemistries. If you wish to repress the reporting of certain chemistries. These screens are used to include or X clude any your analysis tests from the reported results. The enabled status is indicated by a filled button next to the test name. Click next to view additional tests. After you have reviewed the entries on that slide, click done to continue. Then click next to continue. Enable this feature if your facility requires the entry of strip lot numbers and expiration dates before running each test. Click the done button to continue. The authorized operator feature is where you will learn how to setup, add, edit and delete operator IDs. Click select. The disable option should be selected if you wish to grant full access to the analyzer to every operator. The enabled option is used when access is permitted only to authorized users. If this feature is selected, at least one operator ID must be created. Click the add operator button. For this example. We will use the preferred keypad setting an enter a numeric operator ID 9265. Then click enter. The authorized operator screen appears, confirming the entry and displaying those functions that have been enabled for this specific operator. These functions can be disabled or enabled through the edit function. It is recommended that the first operator be the manager or supervisor, since this first operator identified will be given full access to the analyzer to avoid accidental lockout, click done to proceed. The operator's list now includes the new entry. Click exit to continue. Click done to return to the instrument settings screen. Highlight printer settings, then click select. Use this screen to choose what information appears on the results printout, including custom headers as well as selecting an output printer. Click next. After you have reviewed the entries, click next to continue. Click next to continue. Click done to continue. For information on QC settings, refer to the clinic Tech Status Connect System operators guide. Press select to perform software updates. Place the memory stick provided by Siemens with the updated software into the USB port on the back of the connector. Select install software to begin the installation process. The analyzer will turn ODF and will automatically turn on after three minutes. Do not remove the memory stick until the installation process is complete. Click done to continue.

Operator ID Software Update Software U date u Instrument Settings u Instrument Settin s Select System Settings Printer Settings Choose Format Display Contrast Urinalysis Test Authorized Operator Reported Chemistries system Settings Ready operators list operators only View operators list 4:01PM 09-08-2009 Instrument External Yes Herna-Combistix@ Hema-combistix@ Results Format Printer COnnectivity Choose which to include in reported results Authorized OPerator Name operators only Operator ID: Choose which to include in results Mark Positive Sound Connectivity Connectivity printer settin s QC settin s Uristix@ 4 Uristix@ Uro-Uristix@ Results System Settings Platform system Settings operators only Operator ID: operators list 9265 print-out Printer Settin s Uristix@ 4 Display Contrast O URO QC Test Wireless Wiredess OPerator Name Operator ID: NO Ensabled Disabled Serial Number Custom Enternal N-Neostix@ N-NeostixO QC Connectivity connectionty Information Uro-Uristix@ Urinalysis Test Settings CombistixO SG Authorized Operator System Settings Instrument Settings u Instrument Settin s Cassette Test Serial Patient Name . . Enabled Edit Strip Test Ensabled patient ID Yes Patient test..... . Patient test.................... Patient test........... . Store instrument status Printer Settings System Settin s System Settings Sysntem Settings 10 SG QC test...................... QC test................................EnabIed Serial Number serial number in Patient test.................... ......EnabIed QC Settings QC settin s 8 SG Recall results..................... Enabled patient records operators list Nordic Add operator Ensabled NO CombistixO SG MultistixO 5 MultistixO 7 Software Update O BLO Instrument set up.............. Enabled MultistixO 5 MultistixO 7 Done Previous Delete entry Edit reported entry select Next Done View operators list Delete operators list Select operators list Enter chemistries

  • enable connectivity platform
  • units
  • results format
  • instrument settings
  • mark positive results
  • sound preferences