Corindus Robotic PCI - Introduction to CorPath GRX Online Training
This online training provides an interactive general overview of the CorPath® GRX operation, standard features and options that are available on the system.
backgroundpolitico.png Introduction to CorPath GRX Introduction to CorPath® GRX In this online training, we will introduce the most important components of the CorPath GRX and explain the basic operations of the system. Identify the system components Verify compatible wires, catheters and devices Operate the control console Understand basic features 1 4 3 2 Welcome Welcome to the introduction to Core Path G-R-X, online training module. In this online training, we will introduce the most important components of the Core Path G-R-X and explain the basic operations of the system. At the conclusion of this module, you will be able to identify the system components, understand basic features, operate the control console, and verify compativle wires, catheters and devices. Press next to continue. INTERVENTIONAL COCKPIT Precise robotic control of Guide catheter Guidewire Rapid exchange catheter Radiation-shielded workstation 4K resolution monitor BEDSIDE UNIT Optimized bedside unit for radial access Simple setup & in-procedure workflow Devices fixed during intervention Imaging and device agnostic To learn more about the robotic setup in the interventional suite, select the green markers. Robotics in the Interventional Suite Second-generation robotic system Robotics in the Interventional Suite Robotics in the Interventional Suite. Second-generation robotic system. To learn more about the robotic setup in the interventional suite, select the green markers. And then press next to continue. Bedside Unit Extended Reach Arm & Robotic Drive EXTENDED REACH ARM FINE-TUNE CONTROLS ROBOTIC DRIVE BEDSIDE TOUCHSCREEN Key Features Mounts to all commercially available bed rails Bedside touchscreen provides step-by-step workflow instructions Sterile draping for each case Can be positioned for any access point by sliding on rail or adjusting using button on robotic drive 1 4 3 2 To familiarize yourself with the components of the bedside unit, select the green markers. Bedside Unit Extended Reach Arm & Robotic Drive Bedside Unit............Extended Reach Arm and Robotic Drive. The bedside unit Mounts to all commercially available bedrails and Can be positioned for any access point by sliding on the rail or adjusting using the button on the Robotic Drive Sterile draping is available for each case The Bedside Touchscreen provides step-by-step workflow instructions To familiarize yourself with the components of the bedside unit, select the green markers, and then press next, to continue Single-Use Cassette Easily drive and exchange devices Sterile, disposable component of CorPath GRX (1 per procedure) Simultaneous and independent movement of up to 3 devices Attaches to robotic drive To familiarize yourself with the components of the Single-Use Cassette, select the green markers. ROTATIONAL DRIVE Y-CONNECTOR HOLDER TRACK CLAMP LINEAR DRIVE AUXILIARY TRACK RX DEVICE TRACK EXCHANGE GROOVE GUIDEWIRE HOLDER Y-CONNECTOR DRIVE GEAR Attaches to Y-Connector to rotate catheters. GUIDE SUPPORT TRACK Key Features 1 3 2 Single-Use Cassette Easily drive and exchange devices Single-use cassette Easily drive and exchange devices The Single-use cassette is a sterile, disposable component of the corpath GRX, which attaches to the robotic drive, and allows for simultaneous and independent movement of up to 3 devices To familiarize yourself with the components of the single-use cassette, select the green markers then press next, to continue CorPath GRX Compatibility Table with 4 columns and 4 rows CorPath GRX Advance & Retract Rotates Compatibility Guide catheter ü ü 5-7 Fr Guidewire ü ü 0.014” RX device ü û Proximal shaft ≤ 2.3 Fr Table with 1 columns and 1 rows CorPath GRX System is recommended for use with the Abbott Vascular COPILOT® Bleedback Control Valve (Y-Connector) ≤ 2.3 Fr proximal shaft diameter CorPath GRX Compatibility CorPath GRX Compatibility The CorPath GRX is compatible with 5 to 7 french guide catheters oh 1 4 guidewires and RX devices with a proximal shaft less than or equal to 2.3 french. The CorPath GRX system is recommended for use with Abbott Vascular Copilot bleedback control valve y-connectors. Press next to continue. Interventional Cockpit LEAD SHIELDED COCKPIT (OPTIONAL) CONTROL CONSOLE POWER VISION MONITOR Ergonomic seating position Easily positioned in room Can be sterile draped if preferred Houses the control console, power vision monitor & foot switch 1 4 3 2 5 Control console can be moved into control room if desired To familiarize yourself with the components of the interventional cockpit, select the green markers. Key Features Interventional Cockpit The interventional cockpit is led-lined to protect from radiation, and offers an ergonomic seating position. It houses the control console, power vision monitor, and foot switch. It can be sterile draped if preferred, and can easily be positioned in the room. The control console can also be moved into the control room if desired. To familiarize yourself with the components of the interventional cockpit, select the green markers then press next, to continue. Control Console To familiarize yourself with the components of the control console, select the color-coded markers. Key Features Easy to use joysticks for device manipulation Measure anatomy with sub-mm precision technIQ automated movements can be enabled to assist with different procedure tasks Touchscreen enables discrete 1 mm movements & discrete wire rotation Joysticks differentiated by look, feel, size, color, and sound RX DEVICE JOYSTICK CATHETER JOYSTICK EMERGENCY STOP GUIDEWIRE JOYSTICK TURBO BUTTON TOUCHSCREEN 1 4 3 2 5 Control Console The control console has 3 Easy to use joysticks for device manipulation, and the Touchscreen enables discrete 1 millimeter movements & discrete wire rotation. Technique automated movements can be enabled to assist with different procedure tasks, and Measure anatomy with sub-millimeter precision The Joysticks are differentiated by look, feel, size, color and sound To familiarize yourself with the components of the Control Console, select the color-coded markers, and then press next, to continue Workflow with CorPath GRX Workflow with CorPath GRX Not part of this HRT review since it is already approved - HOOD05162003181724 Course Review Congratulations! You have completed the Introduction to CorPath GRX Online Training. Select the objectives listed below to review the material before proceeding to the final assessment. Identify system components Identify system components Understand basic features Understand basic features Operate the control console Operate the control console Verify compatible wires, catheters & devices Verify compatible wires, catheters & devices Course Review Identify the System Components INTERVENTIONAL COCKPIT Precise robotic control of Guide catheter Guidewire Rapid exchange catheter Radiation-shielded workstation 4K resolution monitor BEDSIDE UNIT Optimized bedside unit for radial access Simple setup & in-procedure workflow Devices fixed during intervention Imaging and device agnostic Operate the Control Console RX DEVICE JOYSTICK CATHETER JOYSTICK EMERGENCY STOP GUIDEWIRE JOYSTICK TURBO BUTTON TOUCHSCREEN Understand Basic Features Bedside Unit Single-Use Cassette Interventional Cockpit Mounts to all commercially available bed rails Bedside touchscreen provides step-by-step workflow instructions Sterile draping for each case Can be positioned for any access point by sliding on rail or adjusting using button on robotic drive Sterile, disposable component of CorPath GRX (1 per procedure) Attaches to robotic drive Simultaneous and independent movement of up to 3 devices Ergonomic seating position Houses the control console, power vision monitor & foot switch Can be sterile draped if preferred Easily positioned in room (control console can be moved to control room if desired) Verify Compatible Wires, Catheters & Devices Table with 1 columns and 1 rows CorPath GRX System is recommended for use with the Abbott Vascular COPILOT® Bleedback Control Valve (Y-Connector) Table with 4 columns and 4 rows CorPath GRX Advance & Retract Rotates Compatibility Guide catheter ü ü 5-7 Fr Guidewire ü ü 0.014” RX device ü û Proximal shaft ≤ 2.3 Fr ≤ 2.3 Fr proximal shaft diameter Disclaimer Please note that the learning material is for training purposes only. For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Please note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters\Siemens Healthcare GmbH\Henkestr. 127\ 91052 Erlangen, Germany\Telephone: +49 9131 84-0\siemens-healthineers.com Disclaimer Quiz This assessment will test your retention of the presented content. A passing score of 80% or higher is required to complete the course. You may repeat the assessment as many times as needed. Final Assessment Start Final Assessment What size guide catheters are compatible with the CorPath GRX? 5-7 Fr. 6-9 Fr. 4-6 Fr. Multiple Choice You did not select the correct response. Incorrect Continue That's right! You selected the correct response. Correct Continue Guide catheter Guide catheter Guide catheter Guide catheter Guide catheter Guidewire Guidewire Guidewire Guidewire Guidewire RX devices RX devices RX devices RX devices RX devices Select all that apply - The control console allows for precise robotic control of: Select all that apply - The control console allows for precise robotic control of: Incorrect You did not select the correct response. Continue Correct That's right! You selected the correct response. Continue The cassette allows for simultaneous and independent movement of up to: 1 device 2 devices 3 devices Multiple Choice Continue Incorrect You did not select the correct response. Correct That's right! You selected the correct response. Continue The green joystick on the control console will move the: Catheter Guidewire RX device Multiple Choice Continue Correct That's right! You selected the correct response. You did not select the correct response. Continue Incorrect The Y-Connector attaches to the __________ to rotate catheters: Track clamp Drive gear Linear drive RX device track Multiple Choice You did not select the correct response. Continue Incorrect That's right! You selected the correct response. Correct Continue %Results2.PassPercent%% %Results2.ScorePercent%% Passing Score: Your Score: FINAL ASSESSMENT RESULTS Review Assessment Retry Assessment Complete Module Complete Module FINAL ASSESSMENT RESULTS Sorry, you did not pass this course. Congratulations! You passed. You have completed the Introduction to CorPath GRX Online Training. To access your Certificate of Completion, select the Launch button drop down on the course overview page. You can also access the certificate from your PEPconnect transcript. Congratulations! Exit Congratulations! Question Bank 1 HOOD05162003225629 | Effective Date: 07-Oct-2021 1.1 Welcome 1.2 Robotics in the Interventional Suite 1.3 Bedside Unit Extended Reach Arm & Robotic Drive 1.4 Single-Use Cassette Easily drive and exchange devices 1.5 CorPath GRX Compatibility 1.6 Interventional Cockpit 1.7 Control Console 1.8 Workflow with CorPath GRX 1.9 Course Review 1.10 Disclaimer 2.1 Final Assessment 2.8 Congratulations!
- Robotics
- PCI
- Percutaneous Coronary Intervention
- Radiation Safety