Creating Parallel (MPR) Ranges (VD1xx to VD2xx) Job Aid
Step by step instructions to create parallel ranges
Creating Parallel (MPR) Ranges (VD1xx-VD2xx) Job Aid Advanced Therapies - Application Software VD1xx to VD2xx. **There is an additional job aid available on PEPconnect to determine SW version of the system. Default Orientation: • Axial = Head to Foot, Foot to Head viewing direction = Bottom left segment • Sagittal = Left to Right, Right to Left viewing direction = Upper left segment • Coronal = Anterior to Posterior, Posterior to Anterior = Upper right segment 1. Load a 3D volume into the 4D Taskcard and select any MPR image. 1062577 JeCT NatFil HJ Nom 1/29.1853 2028468 1/26/20 0 11:22:06 AM 1062377 AVICMARIA DynaCT Nat Fil HJ NomY. 2028468 1/26/2010 11:22:06 AM 2. Select Parallel (MPR) Ranges from the Tools menu. Image Tools |Meas ... X-Ray Segmentation 3D Tools Ranges Parallel Ranges ... Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/11/2020 | HOOD05162003096912 Healthineers Job Aid | Creating Parallel (MPR) Ranges Effective Date: 06/11/2020 | HOOD05162003096912 3. Parallel (MPR) Ranges dialogue box opens. IST_LIVER EMBOGUIDE Uni IBT_LIVER_EMBOGUIDE.! 1082577 DynaCT Nat Fill HU Norm ... AXIOM-Artis VC14D 090923 1082577 *4/29/1953 DynaCT Nat Fill HU Norm. 4/23/1953 Presets # 2020468 HFS # 2028468 1/28/2010 11:22:06 AM High resolution Include reference image Number of images 47 Distance [mm] 2.0 Thickness [mm] 2.0 SL 2.0 Review MFR Thick 4 939 MPR Thick ‘‘ 235 Comment LAO 90 / 0 Senes Name axial IBT LIVER EMBOGUIDE. IBT LIVER EMBOGUIDE ... 1082577 DynaCT Nat Fill HU Norm ... AXIOM-Artis 1082577 OM-AUS *4/29/1953 VC14D 090923 DynaCT Nat Fill HU Norm ... *4/29/1953 # 2028468 HFS # 2028468 Go XA 1/26/2010 Close 11:22:06 AM Help Image | Tools |Meas ... | X-Ray Segmentation 3D Tools Ranges TAL MAS UnIck Revieve Remote node zeego Rm302 down o The Ranges dialogue box can be enlarged by double clicking in the Preview window. Double clicking in Preview window again returns window to original size. Additionally, user can scroll through the images to review by left click and hold and dragging up and down within the Preview window to review MPR range images. arallel Ranges XS Presets 2192914 Preview Window noitulo291 dpiH 2epsmi to 1edmul1 [mm] sonsteia OS [mm] 22envoir tremmoO High resolution sixs Include reference image he Number of images 47 Distance [mm] 2.0 Thickness [mm] 2.0 gleH C1026 Comment Series Name axial Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 -19 SIEMENS Job Aid Effective Date: 06/11/2020 | HOOD05162003096912 Healthineers Close Help Page 2 of 6 Job Aid | Creating Parallel (MPR) Ranges Effective Date: 06/11/2020 | HOOD05162003096912 4. Creating the ranges. Which segment creates what ranges? Each MPR segment has the potential to create two different sets of ranges, i.e. Axial segment can create Sagittal and Coronal ranges, Sagittal segment can create Axial and Coronal ranges, and Coronal segment can create Axial and Sagittal ranges. Pay attention to the viewing direction arrows and orientation labels to determine type of range being created. Additionally, user will see a preview of the type of range to be created in the Preview window of the dialogue box. Onc Q HCC TACE DCT ... H Med. Hochschule 103 AXIOM-Artis DynaCT Body Nat Fill H. VD10C 130402\VC10B *1/1/1937 HFS XA 9/20/2013 12:04:46 PM SL 5.0 Thick MPR 1265 0/0 512 Note: Arrows are indicating the projection of the view that is shown in the pop-up box. In this example, viewing direction is Foot to Head so the range to be created from this Coronal View would be the Axial. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/11/2020 | HOOD05162003096912 Healthineers Page 3 of 6 Job Aid | Creating Parallel (MPR) Ranges Effective Date: 06/11/2020 | HOOD05162003096912 The white reference lines show the area to create ranges and the viewing direction. These reference lines can be resized, rotated, and moved as a group. Rotating the lines 90 degrees will easily set up the reference lines for the second set of ranges to be created. To create the third set of ranges, the Parallel Ranges dialogue box needs to be closed completely and a new MPR segment needs to be selected. 1 (1) 1. Resize 2. Rotate (1) (2) (3) (2) ( 1 ) 3. Move (1) Parallel Ranges ? Presets 5. Set all parameters to user specifics. Enter in desired Distance, Thickness, Number of images, etc. Series Name will display in Local Database, Comment will display at the bottom of the MPR range images. Series Name default is but can be modified by user. It is recommended that Distance be less than or equal to Thickness. This will allow for overlap of data and avoid miss- High resolution Include reference image ing data in the MPR ranges. Number of images 47 Distance [mm] 2.0 If High resolution is checked, images will Thickness [mm 2.0 Comment be stored at a 1024x1024 matrix; if un- Series Name axial checked, 512x512 matrix. 17 - Adding a check mark to Include Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Close Help reference image will include the image SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/11/2020 | HOOD05162003096912 with planning lines used to create the Healthineers Page 4 of 6 MPR ranges. Job Aid | Creating Parallel (MPR) Ranges Effective Date: 06/11/2020 | HOOD05162003096912 6. Once all parameters have been set, click on the Calculate and Save icon. Comment Series Name 9 Close Help 7. Ranges will now be displayed in the local database and can be transferred from there to user archive. Patient Transfer Edit View Filter Sort Private Applications Options Help X IN R/// /// / COVID-19 Capers 970] Test SRS & Webex [5] DynaCT Nat Fill HU Normal [ Local Database IBT_LIVER_EMBOI AN Occlusion, P [5] Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/11/2020 | HOOD05162003096912 Healthineers Page 5 of 6 Job Aid | Creating Parallel (MPR) Ranges Effective Date: 06/11/2020 | HOOD05162003096912 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily refle ct the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commerci ally available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 06/11/2020 | HOOD05162003096912 Healthineers Page 6 of 6
- MPR Ranges