Creating Ranges Using TrueD Lite - Biograph mCT and Horizon
TrueD Lite is an application for viewing, manipulating, 3D visualization and comparison of medical images from multiple modalities. This step by step will assist the user with creating ranges that can be sent to another workstation or PACs for viewing
Creating Ranges Using TrueD Lite Biograph mCT and Horizon Description: TrueD Lite is an application for viewing, manipulating, 3D visualization and comparison of medical images from multiple modalities. This step by step will assist the user with creating ranges that can be sent to another workstation or PACs for viewing. Configuring the Output Series Parameters 1. From the Examination Task Card menu, select Options à Configuration. 2. Open TrueD configuration. PETsyngo - Configuration Panel X File DICOM syndo X Patient Patient Patient Transfer Conversion Auto Delete Browser Registration Search CT. Log Expert-i ImageText Scan Protocol E-Logbook Examination Bolus Editor Assistant Configuration Tracking Respiratory HeartView Intervention 3D Viewing Filming Study Gating Layout cm Filming Filming Report DynEva CT Pulmo CT Volume CT Layout Layout Editor Configuration Life VPCT Neuro VPCT Body Update Screen Saver Audit Trail Software Workfl ... Distribution Add Printer Date and Regional and TrueD NEMA PET Time Language ... Examination SIEMENS siemens.com/healthineers Healthineers . Creating Ranges Using TrueD Lite Effective Date: 02/27/2018 | Quality HOOD05162002829039 3. Select the Documentation tab. a. Select the modality Type b. Select the Orientation c. Choose if resampling of functional to anatomical is required d. Select the slice distance. e. Click OK. Resamples the functional images to the anatomical Images Type: Select modality Orientation: Select desired for the range orientation of the ranges Determines the slice distance of ranges TrueD: Configuration General Visualization VOI Layouts Documentation Print Button Configuration Output Series Configuration Auto-save as DICOM.SO Type Orientation Send to Printer CT Transaxial (Feet to Head) . Windows Printer MR Sagittal (Left to Right) · DICOM Printer PETAC Coronal (Front to Back) PETNAC SPECT AC Save VOI as DICOM RT SPECT NAC Resample Functional to Anatomical Fused Slice distance between images 5.00 mm OK Apply Default Cancel Help Creating Parallel Ranges 1. From Patient Browser, select the desired data set to load into TrueD Lite a. PET AC and CT (preferably the 500FOV for the CT) 2. Scroll through images to assure you have good image quality and that the images are registered properly. 3. Select an image from one of the TrueD Lite quadrants from which you would like to create the image. When the quadrant is selected, it’s highlighted around the border. a. Coronal and sagittal images can be created from the transverse. b. Transverse and sagittal images can be created from coronal. c. Coronal and transverse images can be created from sagittal. 4. From the menu, select Image à Define Range. 5. A range of lines will appear of your selected image in the 4th quadrant. Siemens Healthineers Services Page 2 of 5 Creating Ranges Using TrueD Lite Effective Date: 02/27/2018 | Quality HOOD05162002829039 6. Click and drag the center of the range the area that should be center. 7. Adjust the top/bottom or left/right end lines (yellow) to the limits of your range by dragging with the left mouse. WB_CBM_2 Univ of MI PETCT 109950748922.567 *01-Jan-1952 VG50A 27-Mar-2013 10:28:37 FUSED MPF Left mouse Drag to expand and move to or contract position center of ranges range FOV Distance: 5.0 mm A CQ ! Thickness 5.0 mm CT.PT : 50/50 SP A155.9 W 300 T SL: 5.000 40 B 0.00 SUV by 8. In the TrueD Define Ranges window, you can adjust the following parameters. Range Series Description: name of the series that will appear in the the database. TrueD: Define Ranges x Presets Menu: Allows Range Series Desc. Range-AC CT WB 5.0 HD_FoV-Tra-< Constant Number you to save parameters of Images: Keeps for frequently used Presets *Default Parallel Set the number of range settings images constant, no matter where the ranges land Horizontal Range Image Thickness 5.0 mm Distance between images 5.0 mm Vertical Range Number of images 76 Swap Order of Start Close Help Ranges 9. Type the name of the range in the Range Series Description field. 10. If this range that is going to be created often, type the name in the Presets field and click the Save icon. 11. Click the Start button to create the range. 12. Repeat steps 3 to 11 to complete the other two ranges. Siemens Healthineers Services Page 3 of 5 Creating Ranges Using TrueD Lite Effective Date: 02/27/2018 | Quality HOOD05162002829039 Creating MIP (Radial) Ranges 1. Click the segment you would like to use for the radial range (usually the transverse is used) 2. From the Type menu, select MIP. Type Quantification Tools R Specify Thickness .. Anatomical MPR Functional MPR MPR Thick Fused MPR Fused MPR Thick MIP MIP Thin Fused MIP MinID SSD SSD Definition MinIP Thin AC/NAC Rotating MIP MIP Control. Start Rotating MIP Stop Rotating MIP Rotate Clock-wise Save AVI of Rotating MIP ... Cine Control ... 3. From the Image menu, select Create MIP Ranges Image Orientation VRT Type Zoom/Pan Ctrl+F7 Home Zoom/Pan Home Windowing Home Orientation Link time-points Ctrl+F8 Link Settings ... Window 1 Window 2 CT W/L Presets Shift+F2 SUV Attributes ... Shift+F4 Create Ranges Ctrl+R Define Ranges. Create MIP Ranges Siemens Healthineers Services Page 4 of 5 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instruc- tions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety infor- mation like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018
- trued lite