Creating VRT Radial Ranges (InSpace)
Job aid detailing steps to create radial ranges in InSpace software.
Creating VRT Radial Ranges (InSpace) Job Aid Advanced Therapies - syngo Workplace SW VB21, VC10. **There is an additional job aid available on PEPconnect to determine SW version of the system. 1. Load 3D volume into the InSpace Task card and select the VRT image (lower right seg- ment). Patient Applications InSpace Show Mode View Orientation Tools Measure Volumes Options Help Mo_DmaCT_Images .. RESIMPR Thi Mo_DynaCT_Images .. RESIMPER Thin 345 1/1/1900 M LAOTRAO 345 1/1/1900 M 512 Nat Fill Full HU Normal |InSpace CRANICAUD 512 Nat Fill Full HU Normal [InSpace. RANICAUD D AXIOM Atis AXIOM Artis 5/21/2008 5/27/2008 08:2 4:42 08:14:47 Type | Orient |Table | 2D InSpace LA 1209 Brightness Opacity Mo_DmaCT Images, RESIMPR Thin LAOIRAO 345 1/1/1900 M MPR Tools Measure X-Ray 345 1/1/1900 M 512 Nat Fill Full HU Normal |InSpace CRANICAUD -80 512 Nat Fill Full HU Normal DrieperXU ADRES/MIP LAOIRAO 0 CRANICAUD 0 AXIOM-Artis 5/27/2008 08 -. 4:47 Q 1096 hoort from off-line request for F successfully complete 05/2015 3:29:13 PM 2. Select Radial Ranges from the Tools tab. Clip Tools |Measure |X-Ray Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/06/2020 | HOODHOOD05162003101317 Healthineers Job Aid | Creating VRT Radial Ranges (InSpace) Effective Date: 07/06/2020 | HOOD05162003101317 3. When Radial Ranges is selected, an additional dialogue box opens. Rotate VRT into posi- tion for First Frame and left mouse click on First Frame to set. Radial Ranges Total Angle (deg) 180.0% First Frame Step Angle (deg): 5.1¢ Number of Images: 36% F Thick (mm): Rotation Axis: - HF Axis Last Frame Output - Database Load resulting series Show planning lines Reset Start Stop oad Settings Save Settings Close 4. Set all parameters within the Radial Ranges dialogue box. Last Frame will be defined by Total Angle (deg.) setting. Make sure Output is set to Database. Screen Film Last F - Database Mo Output to database 5. After all parameters are set, click on Start. Radial Ranges Total Angle (deg): 180.0% First Frame 1 Step Angle (deg) 5.1% Number of Images 36% E Thick (mm): Rotation Axis: - HF Axis Last Frame Output: - Database Load resulting series Show planning lines Reset Start Load Settings Save Settings Close Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/06/2020 | HOODHOOD05162003101317 Healthineers Page 2 of 5 Job Aid | Creating VRT Radial Ranges (InSpace) Effective Date: 07/06/2020 | HOOD05162003101317 6. Save to Database dialogue box will appear. The default naming of VRT Collection can be changed. (This name will be displayed in the Local Database). Then select Save and Pro- gress bar is displayed. Radial Ranges Save to Database Total Angle (deg): 180.0€ First Frame Step Angle (deg) 5.1¢ Patient Phantom 1, sla Number of Images: 36% Study DynaCT Body E Thick (mm): 5.04 Comment Rotation Axis: - HF Axis Last Frame Save images in new series Output: - Database Appenaimages is senes Load resulting series Image Size = 1024 x 1024 Show planning lines Adjustable Window El Reset Color 30% Save Cancel Start Stop Load Settings Save Settings Close 7. Radial Ranges will be created and saved to the Database. If new ranges are not displayed in the Local Database, select Refresh from the Browser tool bar icons. Patient Browser BOX Patient Applications Transfer Edit View Filter Sort Private Applications Options Help 1 21 Local Database Phantom 1, sla DynaCT Body ([3] DVD 20.04.24-09:04:10-[ [2] 111/11 / DVD-R 20.04.29-09:28:04-[ [1] DynaCT Body Nat Fill HU Nor 20.02.26-11:37:54-[ [1] Images for VOI selection 20.02.26-08:42:06-[ [1] 8sDCT Body 20.02.06-08:47:52-[ Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/06/2020 | HOODHOOD05162003101317 Healthineers Page 3 of 5 Job Aid | Creating VRT Radial Ranges (InSpace) Effective Date: 07/06/2020 | HOOD05162003101317 8. To send Radial Ranges to archive, highlight the data in the Local Database to be sent and select the Send to icon from the Browser tool bar icons. Select destination. Patient Browser Patent Applications Transfer Edt View Eiter Soit Private Applications Options Help Local Database _ Phantom 1, sia DynaCT Body [3] DVD 20.04.24-09:04:10-[ [2] DVD-R 20 04.29-09:28:04-[ JOyaOi Body Nat Fil HU Nor Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/06/2020 | HOODHOOD05162003101317 Healthineers Page 4 of 5 Job Aid | Creating VRT Radial Ranges (InSpace) Effective Date: 07/06/2020 | HOOD05162003101317 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/06/2020 | HOODHOOD05162003101317 Healthineers Page 5 of 5
- Creating VRT Radial Ranges (InSpace)