Creating VRT Volume (Radial) Ranges (VD1xx-VD2xx)
Creating VRT Volume (Radial) Ranges (VD1xx-VD2xx)
Creating VRT Volume (Radial) Ranges (VD1xx-VD2xx) Job Aid Advanced Therapies - Application Software VD1xx to VD2xx. **There is an additional job aid available on PEPconnect to determine SW version of the system. 1. Load a 3D volume into the 4D Taskcard and select VRT image (lower right segment). ihrem Nat Fill HU Sh .. Aneurysm Nat Fil HU Sh ... 120328 3:44 AM SL 2.0 MPR Thick LAO 90 / 0 MPR Th IBT ANEURYSM ANALY ... 03221047 Aneurysm Nat Fill HU Sh ... AXIOM- Artis VC14/ 120328 4/171965 5/7/2013 9: 13:44 AM F 4649 Review? 1909 AO 47 / CAUD 20 2. Select Volume (Radial) Ranges from the Tools menu. Image Tools |Meas ... X-Ray Segmentation 3D Tools Ranges Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/29/2020 | HOOD05162003096952 Healthineers Job Aid | Creating VRT Volume (Radial) Ranges Effective Date: 05/29/2020 | HOOD05162003096952 3. Volume (Radial) Ranges dialogue window opens. Volume Ranges ? X Presets Select Axis: Vertical = Rotation Horizontal = Tumble Enter in desired Angular Range, Number of images, etc. Series Name will display in Local Database, Com- ment will display at the bottom of the radial range im- ages. Series Name default is but can be modified by user. If High resolution is checked, images will be stored at a 1024x1024 matrix; if unchecked, 512x512 matrix. Axis Vertical . Clockwise Horizontal Counterclockwise" Vertical Number of images 18 Angular range [o] Comment Series Name High resolution Close Help Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/29/2020 | HOOD05162003096952 Healthineers Page 2 of 5 Job Aid | Creating VRT Volume (Radial) Ranges Effective Date: 05/29/2020 | HOOD05162003096952 4. The Ranges dialogue window can be enlarged by double clicking in the Preview window. Double clicking in Preview window again returns window to original size. Additionally, user can scroll through the images to review by left click and hold and dragging up and down within the Preview window to rotate and review VRT range images. Volume Ranges ? X Presets Volume Ranges X Presets Preview Window Axis Vertical · Clockwise Horizontal Counterclockwise" Vertica Vertical Number of images 18 Axis . Clockwise Horizontal Angular range [º] 180 Vertical Counterclockwise Number of images 18 Comment Angular range [o] 180 + Series Name Comment Series Name High resolution High resolution Close Help Close Help Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/29/2020 | HOOD05162003096952 Healthineers Page 3 of 5 Job Aid | Creating VRT Volume (Radial) Ranges Effective Date: 05/29/2020 | HOOD05162003096952 5. Once parameters have been set, click on the Calculate and Save icon. Comment Series Name High resolution Close Help 6. Ranges will now be displayed in the Local Database and can be transferred to user archive. atient Browser ent Transfer Edit View Filter Sort Private Applications Options Help ? ? gz BT_STENOSIS_ANALYSI Send to .. IBT_Bone_Removal_CT_/ R/// / / / / Local Database . IBT ANEURYSM ANALYS RICA Aneurysm PED [970] Scheduler 20.05.26-06:39:00-STD [2] Angio Sub HU Normal [InSpace3D] RecycleBin 2D_Image_Collection [2] Aneurysm Nat Fill HU Sharp [InSpace3D] 11////H / R/ / / / / / / Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/29/2020 | HOOD05162003096952 Healthineers Page 4 of 5 Job Aid | Creating VRT Volume (Radial) Ranges Effective Date: 05/29/2020 | HOOD05162003096952 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the soft- ware and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Pl ease contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples o nly. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/29/2020 | HOOD05162003096952 Healthineers Page 5 of 5
- Creating VRT Volume
- VD1xx-VD2xx