DCA Vantage® Analyzer System Overview Online Training
Locate major system components and determine their function, navigate main screens to run test sequences, and backup, transfer, and restore system settings.
Welcome to the DCA Vantage® Analyzer System Overview Online Training Course. The DCA Vantage® Analyzer measures the percent of Hemoglobin A1c in blood, low concentrations of Albumin in urine, Creatinine in urine, and the Albumin/Creatinine ratio in urine. Tests performed using the DCA Vantage® Analyzer are intended for in vitro diagnostic use. Select Next to continue. Identify symbols and buttons and their functions Identify system hardware components and their functions Identify system screen components Upon successful completion of this course, you will be able to: Select Next to continue. Upon successful completion of this course you will be able to: Identify key areas of the Standard Curve screen. Describe three ways to perform calibrations on the Sysmex® CA-7000 System. Identify the steps required to set up and perform a calibration and List key points when evaluating a new standard curve. Congratulations. You have completed the DCA Vantage® Analyzer Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. In this online training course, you learned how to: Identify system hardware components and their functions The analyzer consists of four functional areas: The Reagent Cartridge compartment holds the reagent cartridges. Tests are run in this area. The analyzer can run HbA1c and Microalbumin/Creatinine reagent cartridges The onboard barcode reader calibrates the system and scan the reagent cartridges and control cards The interactive touchscreen displays messages, options, and requests for information. Operator response is made by selecting the appropriate key symbol on the touch screen The internal thermal printer provides a record of the completed test results The power cord is connected into the power cord receptacle. The system is turned on by pressing the power switch to the ON position. A Fuse Holder is located between the power cord and the power switch. The following interface connections are located on the back of the instrument: RJ45 for Ethernet devices USB for flash drive devices 9 pin for optional external barcode scanner RS232 (serial) for printer or LIS connection An air filter compartment located on the back of the system houses a removable air filter. Identify system software components The DCA Vantage® Analyzer software uses a consistent layout. Responses are entered using a numeric or alphanumeric keypad or system buttons and icons. The DCA Vantage® Analyzer does not support the connection of an external computer keyboard or a mouse to enter data. When the system is not in use for more than 30 minutes, the Power Save Mode automatically turns on. Simply any location on the screen to resume operation. The Home Screen displays after initialization of the system. This screen displays the state of the system and is the starting point for Patient and Control Test Sequences. A Test Sequence is a series of software user interface screens that guides the operator through the tasks required to perform a test on a sample. System Responses are made by selecting the appropriate key symbol on the screen. If the analyzer is in the Not Ready state, Patient or Control Test Sequence cannot be initiated. An alert message will display the reason why the system is not ready. If the system is in the Ready State, a test can be initiated by scanning either an HbA1c or a Microalbumin/Creatinine test cartridge. The Recall Menu and the System Menu are accessed from the Home Screen. Responses are made by selecting the appropriate key symbol on the screen. Identify symbols and buttons and their functions The Home screen also displays the Navigational and Contextual Help Button Area. The Navigational Buttons include: The Menu Button provides access to Control Tests, System Maintenance, System Setting, and System Tests Calibrations and System Tests Menu allows access to the Calibrations or System Tests Menu Data Recall Menu provides access to the Data Recall Menu Help displays a Help screen with information about the screen. Help is not available on all screens Notifications or Error messages display at the Home Screen of the DCA Vantage® Analyzer, and provide you with information about the state of the system. An Event Notification window displays at the Home Screen when a maintenance task is due, an error event occurs, or a required or optical control test notification is posted. Select Next to continue. 이 센셕에서 여러분은 IMMULITE 면역 분석 시스템이 VersaCell X3 시스템에 연결되어 있을 때 샘플 튜브, 테스트 오더, 그리고 결과에 대해 필요한 처리 과정 단계를 배울 것입니다. IMMULITE 면역 분석 시스템과 VersaCell X3 시스템의 연결은 IMMULITE 면역 분석 시스템이 인터페이스 휠을 필요로 하지 않는다는 점에서 다른 장비와VersaCell X3의 연결과 다릅니다. 대신에 자동화 랙이 IMMULITE 시스템의 샘플 카루셀에 설치되어 있습니다. 로봇 암은 튜브를 바로 VersaCell X3 시스템 드로워에서 이 자동화 랙으로 운반합니다. 튜브가 이동하는 동안 로봇 암은 튜브 바코드를 스캔하고 튜브를 IMMULITE 시스템의 자동화 랙으로 운반합니다. 그 다음 VersaCell X3 시스템은 오더를 IMMULITE 시스템으로 전송합니다. IMMULITE 시스템 샘플 프로브는 처리를 위해 자동화 랙에 있는 튜브에서 샘플을 흡입합니다. 튜브가 더 이상 자동화 랙에 있을 필요가 없을 때 로봇 암은 이 튜브를 드로워로 되돌려 보냅니다. IMMULITE 시스템은 샘플을 처리하고 결과를 VersaCell X3 시스템으로 전송합니다. 그 다음 VersaCell X3 시스템은 결과를 LIS로 보냅니다. IMMULITE 시스템과 연결되어 작동하는 VersaCell X3 솔루션을 보려면 링크를 선택하세요. The DCA Vantage® Analyzer consists of 4 functional areas: Reagent Cartridge Compartment Onboard Barcode Reader Display Screen Printer Hardware Components and Functions Learn about hardware components and their functions. Slide NumberText BlocksCalloutsAudio ScriptImage File1Display Screen The interactive touch screen displays: Messages Options Requests for information Respond to messages by touching the appropriate key symbol on the screen. Select Next to continue. Note: If audio does not automatically start, select the play arrow in the top left to begin.The display screen is an interactive touch screen where messages, options, and requests for information are displayed on the system. Operator response is made by selecting the appropriate key symbol on the touch screen.2Reagent Cartridge Compartment The Reagent Cartridge compartment holds the reagent cartridges. Tests are run in this area. The analyzer can run Hemoglobin A1c and Microalbumin/Creatinine reagent cartridges. Select Next to continue.The Reagent Cartridge compartment holds the reagent cartridges. Tests are run in this area. 3Printer The internal thermal printer prints a report of the completed test results. The thermal paper storage compartment is located on the rear of instrument. Select Next to continue.The internal thermal printer prints a record of the completed test results. The thermal paper storage compartment is located on the rear of instrument. 4Onboard Barcode Reader The onboard barcode reader: Calibrates the system Scans reagent cartridges Scans Calibration and Control Cards Select Next to continue. Select the number to review the corresponding text.CalloutsInternal barcode readerThe internal barcode reader is used to calibrate the system. It also scans the reagent cartridges and control cards.5Interface Connections The DCA Vantage® Analyzer provides the following interface connections: RJ45 for Ethernet devices USB for flash drive devices 9 pin for optional external barcode scanner RS232 (serial) for printer or LIS connection Select Next to continue. Select each number to review the corresponding text.CalloutsRJ45 portUSB port9-pin portRS232 portThe analyzer includes several connection ports. The RJ45 port provides connection for Ethernet devices. A USB flash memory drive can be inserted into the USB port for backing up and restoring system data. A 9 pin port provides connection for an optional external barcode scanner. The serial port, or RS232, is used to connect an external printer or provide LIS connection.6Power The system is turned on by pressing the power switch to the ON position. The power cord connects into the power cord receptacle. The Fuse Holder is located between the power cord and the power switch. Select Next to continue.Select each number to review the corresponding text.CalloutsPower ReceptacleFuse HolderPower SwitchA power cord connects into the power cord receptacle. The system is turned on by pressing the power switch to the ON position. The Fuse Holder is located between the power cord and the power switch.7Air Filter An air filter compartment located on the back of the system houses a removable air filter. When complete, select the X in the upper-right corner to close the window and continue.A compartment located on the back of the system houses a removable air filter. Follow your laboratory specific guidelines for the frequency to process QC material. Siemens has several QC guideline examples, including that 2 levels of QC material be run at least every 24 hours to verify system performance and QC be done following every calibration. Siemens recommends that following a lamp change or the change of the RRV cuvettes, all analytes be calibrated and QC be performed. Lastly, Siemens recommends that following field service preventive maintenance or troubleshooting, all analytes must be calibrated and/ or QC be performed. Select the links to learn about loading QC material on the system, ordering QC tests, and monitoring inprogress QC samples. The DCA Vantage® Analyzer Home Screen displays after initialization of the system. The Home Screen displays the state of the system and is the starting point for Patient and Control Test Sequences. A Test Sequence cannot be initiated If the analyzer is in the Not Ready state. Note: A Test Sequence is a series of software user interface screens that provides guidance through the tasks required to perform a test on a sample. Responses are made by selecting the appropriate key symbol on the screen. System Screen Components Learn about the location of Home Screen Components. Base ImageHotspotsText BlocksImage FileScreen TitleModule Icon and TitleTime and DateContent AreaNavigation Buttons Aptio 자동화 시스템 개요 온라인 교육 코스에 오신 것을 환영합니다. Aptio 자동화는 검사실에서의 샘플 처리를 자동화하는 유연한 솔루션입니다. 하나의 시스템에 여러 분석 장비를 통합함으로써, 최적화된 분석 및 작업 흐름을 위해 샘플들을 효율적으로 장비로 이동시킬 수 있습니다. 필요할 경우, Aptio 자동화는 샘플의 분석 전, 분석 후 처리를 제공할 수 있습니다. 이것은 검사실에서의 접수부터 저장 및 아카이브에 이르기까지 샘플 처리를 관리할 수 있습니다. 이 코스에서 여러분은 Aptio 자동화의 주요 구성 요소 및 그 기능에 대해 배우게 될 것입니다. 계속하려면 다음을 선택하세요. The Home Screen displays Navigational and Contextual Help Buttons: Menu Turn Off Recall Help Menu Download and print a PDF on the common symbols. Navigational Buttons and Contextual Help Buttons Learn about Navigational Buttons and Contextual Help Buttons. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90005465/sim_DCAV_MainScreenNav_HTML5_800x600___9/sim_DCAV_MainScreenNav_HTML5_800x600__9.swfHTML5 File:/content/generator/Course_90005465/sim_DCAV_MainScreenNav_HTML5_800x600___9/index.htmlPDF File: Aptio 트랙은 모든 모듈 및 분석 기기로 샘플의 자동화된 이동을 제공합니다. 이것은 복합적인 트랙 구성 요소 중에서 4개의 유형으로 구성되어, 샘플 튜브의 움직임을 제어합니다. 샘플 캐리어,즉 퍽은 트랙의 샘플 튜브를 전송하는데 사용됩니다. 샘플 캐리어는 각 샘플 캐리어에 내장된 RFID 칩 덕분에 무선 주파수 ID를 통해 전자적으로 식별되는 고유 ID를 가지고 있습니다. 샘플 캐리어 ID (RFID) 및 샘플 튜브 ID (바코드)는 트랙에 있는 동안 샘플 추적 목적을 위해 짝으로 이루어 집니다. 트랙 구성 요소 및 샘플 캐리어에 대한 자세한 내용을 배우려면 아래의 링크를 선택하세요. Notifications or Error messages display at the Home Screen of the DCA Vantage® Analyzer and provide information about the state of the system. Notifications and Messages Learn about the DCA Vantage® Notifications and Error Events. Base ImageHotspotsText BlocksImage FileEvent Notification AreaEvents Button
- DCA-Vantage
- DCAVantage
- Hemoglobin Alc
- HbA1c
- albumin
- creatinine
- urine
- hardware
- software
- symbols
- navigation buttons
- reagent cartridge compartment
- onboard barcode reader
- display screen
- printer
- module icon
- screen title
- time and date
- content area
- menu
- turn off
- recall
- help menu
- notifications
- error messages