Cleaning the IMT System Video
This video provides instructions on how to clean the IMT module on the Dimension® Systems.
Monthly cleaning of the IMT system. Tubing an IMT port with bleach. Destroy sensitive electrode membranes in the quick light multisensor with the instrument in standby. Access the IMT system clean screen from the operating menu by pressing F4. System prep. F3 IMT. F8I Mt sis clean. From the IMT system. Clean screen. Press F3, open port. Dispense approximately 1 milliliter of undiluted bleach into the I empty port. 10 times. Allow the poor to empty completely before each subsequent edition of bleach. Next, dispense approximately 1 milliliter of water into the IMT port 10 times. Allow the port to empty before each subsequent edition of water. Press F3. Close port. Fill the port again with undiluted bleach. An press F8 start soak. The fluid sits inside the tubing for two minutes. When the soak is finished, the system automatically primed standard A. When this process is completed, filled the port with fresh serum or plasma free of hemolysis, icterus or lipemia. Press F8, start soak. Make sure the fluid is flowing in the tubing. The fluid sits inside the tubing for two minutes. When the soak is completed, the system primes standard A. Press F7, change sensor. From the IMT consumables screen press F7. Change sensor. Next, replace the quick light integrated multisensor. Press F 8 Store to update when the sensor is replaced, the system automatically primes salt bridge solution and displays the IMT condition and Illusion check screen. Next, perform the condition and dilution check procedure for additional information on this procedure, refer to the Dimension Excel module assay Measurement IMT. Document the cleaning on the monthly maintenance log sheet.
Diluent Tinp Left: 2 days Port INT bleach/conditioning soak due in F3: CHANGE FLUSH F3: OPEN PORT SYSTEM CLEAN CONDITION F4: COND/DILCHK Replace consurbte. press the apprc F4: COND & DILCHK F3: CLOSE F3: CLOSE PORT F3: OPEN PORT VSOR F8: START SOAK F6: CHANGE F8: STORE CHANGES F4: SYSTEM PREPK F8: START NSOR and then store changes. OR F 3: 1M T F3: F3: F7: CHANGE SENSOR NT I IMPORTANT! Port Priming Salt Bridge Solution. F8: START F8: WIT SYS CLEAN F7: CHANGE SENSOR AFTER PERFORMING THE BLEACH Port F8: SEGMENT STATUS F8: DAILY MAINT. F7: WIT CONFIG F7: CONFIG F7: PUMP PRIME F2: CHANGE STD B CHANGE STD A YOU MUST REPLACE THE QUIKLY- Bleach wilt ruin or seriousl F5: CHANGE SALT F6: CHANGE
- monthly
- maintenance