Dimension® RxL Max® Integrated Chemistry System Competency Checklist
Education resource material designed to document competency mastery on-the-job. This Competency Checklist represents all learning objectives for this training area.
Dimension® RxL Max® Integrated Chemistry System Competency Checklist Once an employee has acquired the necessary knowledge and skills to perform basic operation tasks this checklist can be used to observe the employee perform the required tasks for their core job responsibilities and to document demonstrated competency. The observer places their initials and date beside the task when it is performed successfully. Successful completion for each task is determined by the facility. The standards used to evaluate can be documented in the “Criteria” section below. Use the area on the last page to record comments or areas of improvement. If necessary, the observer can record recommended next steps of action for areas of improvement or development opportunities. When all required tasks are completed, the supervisor and employee sign and date this document as a record of completion. Criteria - Standards for successful completion of each task (e.g. Accuracy, Time, Quality, etc.): Observer’s Initials and Completion Date Topic/Tasks System Overview Read the Safety section of the Operator’s Guide Identify and locate major hardware components Navigate the software Load a Flex® reagent cartridge HM Locate components of the HM system Identify HM consumables and their function Define the function of each HM component Access the Heterogeneous Module System Counter screen Replace an HM consumable Add HM reaction vessels and empty the waste container Resolve HM chemistry problems IMT Locate components of the IMT system Define the function of each IMT component Replace IMT Fluids Replace the QuikLYTE® Integrated Multisensor Condition IMT and run a Dilution Check Resolve a Failed Dilution Check Update the appropriate Maintenance Log Reagent Monitoring Perform reagent hydrations Process HIL samples and interpret HIL test report messages (if applicable) Respond to STAT Status Respond to Supply Alert Locate method specific information in the reagent cartridge Instructions for Use (IFU) Process samples using Manual and Automatic dilutions Process samples using Manual and Automatic dilutions Process samples with panic repeats Respond to the Sample Alert key Sample Processing Evaluate sample volumes using the Tube Fill Guide Load and process barcoded and non-barcoded sample tubes Use the Manual Query feature Add samples during processing Quality # HILS1887 Effective Date: 06/09/2017 Page 1 of 4 SIEMENS siemens.com/healthineers Healthineers Dimension® RxL Max® Integrated Chemistry System Competency Checklist Monitor Sample Status Explain the printed test report and test report messages Load and process sample cups Add tests to a sample Process samples with insufficient volume Manual Calibration Set up a method for manual calibration Review the data for a method calibrated manually Apply the criteria to accept or reject a calibration QCC PowerPak Set up Configure QC and Calibration Alert keys* Define QC ranges and status* Define/Edit a QC Product Define/Edit a QC Panel Define a Calibrator Product Setup Calibration Auto Acceptance *Exercise may be completed without changing configurations on instrument QCC PowerPak Calibration and Quality Control Define Calibrator Products* Group Cal Alerts Process a Calibration Process barcoded QC Process manual QC Group QC alerts View Calibration History Navigate Lab Data Storage *Not required if completed “QCC Setup” learning object Weekly/Monthly Maintenance Clean HM wash probes and R2 Reagent probe - Weekly Stylet HM wash probes Replace HM pump heads Replace IMT pump tubing Replace the Monopump Valve Seal Clean IMT system Clean/Replace air filters Update the Maintenance Log Cycle Based Maintenance Replace the cuvette diaphragm Replace the film cartridge Clean the sample probe tip Replace a probe tip Update the Maintenance Log Periodic Maintenance Identify the 2 procedures for cleaning cuvette windows Clean cuvette windows Perform a controlled power shutdown and startup Lower and raise the thermal chamber Replace the source lamp and perform all follow up procedures Update appropriate Maintenance Log Troubleshooting Access help procedures for error messages Quality # HILS1887 Effective Date: 06/09/2017 Page 2 of 4 SIEMENS siemens.com/healthineers Healthineers Dimension® RxL Max® Integrated Chemistry System Competency Checklist Troubleshoot instrument errors • Investigate Bad Cuvette • Differentiate Lost Steps and Cannot Find Home Error Messages • Identify troubleshooting steps for IMT Failed to Autoalign • Resolve System Check failures Troubleshoot non-instrument related issues • Troubleshoot verification statistics • Locate information in an IFU • Load a third lot of reagent • Resolve a non-reportable test report message Alert Keys Identify conditions which generate a STAT Status Alerts Interpret a Sample Alert screen Configure a Supplies Alert Clear a QC Alert Identify a Calibration Alert threshold Customization Display the current automatic instrument options Navigate to the Method Parameters screen Identify the Amylase Test Parameters View the Amylase Intervals Configure panic values Configure reflex testing View the Method Coefficients Configure the auto cuvette removal System Configuration Locate instrument software version Locate current instrument options Create, use and delete a profile panel View system date and time format Review Sample ID and Computer Menu screen entries Interpret IMT not Config Status Edit Printer Set Up Remove temperature override icons HIL Set up the HIL feature Perform Reagent Hydrations Configure STAT Status Configure Supplies Alert Configure Automatic dilutions Set up Panic Rerun VersaCell® System Connected to Dimension® System Perform Startup Run Controls Identify STM Components and functions Navigate the Dimension® system software to access STM information Use the STM Replace consumables and empty waste Quality # HILS1887 Effective Date: 06/09/2017 Page 3 of 4 SIEMENS siemens.com/healthineers Healthineers Dimension® RxL Max® Integrated Chemistry System Competency Checklist Maintain the STM Troubleshoot STM Errors Comments Areas of Improvement Next Steps Primary Operator Secondary Operator has been trained on the above documented tasks Supervisor: Employee: Date: Quality # HILS1887 Effective Date: 06/09/2017 Page 4 of 4 SIEMENS siemens.com/healthineers Healthineers
- demension
- rxlmaxx
- rxlmax
- competency
- training
- mentor
- checklist
- consolidated