Dimension® Integrated Chemistry System Alert Keys Online Training
Configure STAT Status, Sample, Supplies, Calibration & QC Alerts.
Welcome to the Dimension® Systems Alert Keys Online Training course. Alert keys are set up to provide warnings of operating conditions requiring a quick response. Select Next to continue. Configure Calibration Alerts Configure QC Alerts Configure Sample Alerts Configure STAT Status Alerts Configure Supplies Alerts Upon successful completion of this course, you will be able to: Select Next to continue. IMT(あいえむてぃー)消耗品の交換は、IMT(あいえむてぃー)消耗品の交換画面を使って簡単に行うことができます。この画面には、残りテスト数、残り時間、カウントの更新方法などが表示されます。 IMT(あいえむてぃー)の消耗品を交換し、変更を保存すると、システムは必要に応じて自動的にプライミングと較正を行います。 Congratulations. You have completed the Dimension® Systems Alert Keys online training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Configure STAT Alerts Three conditions can trigger the STAT status Alert key to change colors: The STAT status alert key changes color to RED if the STAT sample is complete but no result. The STAT status alert key changes color to RED if the STAT sample did not run within a specified time. The STAT status alert key changes color to YELLOW if the STAT sample is completed. Configure Sample Alerts The Sample Alert key changes color to yellow when a test is being reprocessed for any of these reasons: Autodilute Reflex test Panic repeat Configure Supplies Alerts The Supplies alert key changes color to Yellow when the number of test available is equal to or less than the configured threshold. Configure QC Alerts The QC Alert key changes color to yellow to alert you of the following conditions: When QC result is HIGH or LOW When QC result is greater than 2 standard deviation When QC results have a process error When QC expires or is about to expire Configure Calibration Alerts The Calibration Alert key changes color to yellow if a flex is in inventory but not calibrated, when calibration is expired or when a calibration is about to expire in a specified time. Select Next to continue. Congratulations. You have completed the ADVIA Centaur XPT System Update Online Training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Three conditions can trigger the STAT Status Alert key to change color: The STAT status alert key changes color to RED if the STAT sample is complete but no result. The STAT status alert key changes color to RED if the STAT sample did not run within a specified time. The STAT status alert key changes color to YELLOW if the STAT sample is completed. STAT Status Alerts Learn how to configure STAT Status Alerts. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90004449/sim_DIM_StatStatusAlerts/sim_DIM_StatStatusAlerts/sim_DIM_StatStatusAlerts.htmHTML5 File:/content/generator/Course_90004449/sim_DIM_StatStatusAlerts_HTML5_800x600/index.htmlPDF File: The updates to processing quality control on the ADVIA Centaur XPT system include newly designed screens for creating control definitions, ordering QC tests, and reviewing data and new options for automatic QC ordering. Select the links to learn about processing QC on the ADVIA Centaur XPT system. The Sample Alert key color changes to yellow when a test is being reprocessed for any of these reasons: Autodilute Reflex Test Panic Repeat Process Error Sample Alerts Learn how to configure Sample Alerts. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90004449/sim_DIM_SampleAlertKeys/sim_DIM_SampleAlertKeys.htmHTML5 File:/content/generator/Course_90004449/sim_DIM_SampleAlerts_HTML5_800x600/index.htmlPDF File: The weekly maintenance tasks are cleaning the water bottle and emptying the water trap. The procedures to perform these tasks have not changed. Cleaning the water reservoir is no longer required. To decontaminate the reservoir, a UV light in the reservoir automatically turns on for 90 seconds at system startup and then every 23 hours. Select next to continue. The Supplies alert key color changes to Yellow when the number of test available is equal to or less than the configured threshold. Supplies Alerts Learn how to configure Supplies Alerts. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90004449/sim_DIM_SuppliesAlerts_800x600/sim_DIM_SuppliesAlerts_800x600/sim_DIM_SuppliesAlerts.swfHTML5 File:/content/generator/Course_90004449/sim_DIM_SuppliesAlerts_html5/index.htmlPDF File: Upon successful completion of this course you will be able to identify the ADVIA Centaur XPT system hardware differences, navigate the software, describe how to perform a calibration, list the steps to process QC, describe how to process patient samples, list the maintenance tasks, and describe how to perform basic troubleshooting. Select next to continue. The QC Alert key changes color to yellow to alert you of the following conditions: When QC result is HIGH or LOW When QC result is greater than 2 standard deviation When QC results have a process error When QC expires or is about to expire QC Alerts Learn how to configure QC Alerts. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90004449/sim_DIM_QCAlerts_800x600/sim_DIM_QCAlerts_800x600/DimensionSystemQCAlerts_800x600.swfHTML5 File:/content/generator/Course_90004449/sim_DIM_QCAlerts_800x600_html5/index.htmlPDF File: The CALIB Alert key color changes to yellow under these conditions: A flex is in inventory but not calibrated When calibration is expired When a calibration is about to expire in a specified time Calib Alerts Learn how to configure CALIB Alerts. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90004449/sim_DIM_CalibAlerts/sim_DIM_CalibAlerts/sim_DIM_CalibAlerts.htmHTML5 File:/content/generator/Course_90004449/sim_DIM_CalibAlerts_HTML5_800x600/index.htmlPDF File: 調整と希釈チェックを行うことで、1:10(いちたいじゅう)希釈の精度と正確さを確認します。 希釈チェック液は冷蔵保存し、1(いち)インチ以下になったら廃棄してください。サンプルカップに注いで使用します。
- consumables