Dimension® Integrated Chemistry Systems Dilutions Online Training
Perform manual sample dilutions through software interaction and Instructions for Use sheet. Process serum/plasma samples to dilute automatically. Monitor the Sample Alert key. This clinical laboratory training qualifies for continuing education units (CEU).
Welcome to the Dimension® Systems Dilutions Online Training course. Sample dilution ensures accuracy of test results. In this course, you will learn how to configure three types of sample dilutions. Select Next to continue. Configure automatic urine dilutions Configure manual dilutions Configure user programmable auto dilutions Upon successful completion of this course, you will be able to: Select Next to continue. The eSie VVI technology provides the basic parameters needed to do a complete strain and strain rate quantification for all chambers of the heart. Siemens is also an active partner in the Strain Standardization Committee. This committee was formed to bring all of the vendors together to ensure that all measurements are within an acceptable validation of strain and strain rate measurements. Select the link below to learn more about eSie VVI Velocity Vector Imaging Technology. Congratulations. You have completed the Dimension Systems Dilutions online training course. Listed below are the key points that have been presented. Take time to review the material before you proceed to the final quiz. Configure User Programmable Auto Dilutions The system can be configured to dilute select urine and serum/plasma samples when results are above the defined assay range. To use the Auto feature, configure the automatic rerun and automatic dilutions fields on the System Configuration screen to ON. Use the Operator's Guide, Customizng section to locate the auto dilute volumes for each method. Set up these auto dilute volumes on the Method Parameters screen. Program Automatic Urine Dilutions The system performs AUD for BUN, Creatinine, Phosphorous and Uric Acid tests when the sample fluid type is urine. On the Enter Data screen, change the fluid type to urine. The system then automatically dilutes the sample times 10. Once the tests have been processed, review the results on the Test Results screen. Program Manual Dilutions Setup manual dilutions if the test result is above the assay range or if the system diluted the results and the result is still above the assay range. Prepare an off-board dilution with the diluent identified in the Method Instruction for Use. The system automatically calculates the final result if the dilution factor is entered in the Enter Data screen. Select Next to continue. The Dimension System can perform two types of automatic dilutions: Automated Urine Dilutions (AUD) - for BUN, CREA, PHOS and URCA Autodilute (AD) - user programmable for urine and serum/plasma samples The system also provides a manual dilution option. Configure Dilutions Learn how to configure sample dilutions. Instructions:If media does not automatically start, select the play arrow to begin.Flash File:/content/generator/Course_90004419/sim_DimSystem_DilutionsSetup_9/sim_DimSystem_DilutionsSetup.swfHTML5 File:/content/generator/Course_90004419/sim_DimSystem_DilutionsSetup_9/index.htmlPDF File: