Dot Cockpit – Build Whole Spine Dot Engine - Eline & Numaris X
This Job Aid provides workflow instructions on how to build a Whole Spine Dot Engine in the Dot Cockpit Customer User Tree on Eline or Numaris X software.
Dot Cockpit – Build Whole Spine Dot Engine – Eline & Numaris X Job Aid Dot Cockpit – Build Whole Spine Dot Engine Eline & Numaris X Job Aid This Job Aid provides workflow instructions on how to build a Whole Spine Dot Engine in the Dot Cockpit > Customer User Tree on Eline or Numaris X software. 1. Open Dot Cockpit Dot Dot Cockpit - Explorer Cinchp Explore Program Editor 2. Select Siemens Tree > t-Spine > t-spine Browse Import Export Dot Engine SIEMENS program a. Right Mouse > Copy head c.spine I-spine T-Spine Dot Engine Expand clinical libranes Now library + I-spine Find Copy Ctrl+C › whole-spine >neck soft tissue Print > Thorax Export ... › heart Check License breast Edit Properties Dot Cockpit - Explorer 3. Select User Tree > Whole Spine Explorer Program Editor a. Right Mouse > Paste – copies T-Spine Dot Browse Import Export Engine to New Region selected USER * Abdomen Brain he-spine hip knee 20 knee 3D + ventncular Whole Body Whole Spine Collapse New Find Copy Ctrl+C Paste Ctrl+V Delete Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/04/2020 | HOOD/HILS Healthineers Job Aid | Dot Cockpit –Build Whole Spine Dot Engine – Eline & Numaris X Effective Date: 08/04/2020 | HOOD05162003111621 Dot Cockpit - Explorer Explorer Program Editor Browse Import Export .. .. 4. Rename T-Spine Dot Engine USER program a. Right mouse > T-spine Dot Engine i. Select Rename Abdomen ii. Enter Whole Spine Dot Engine Brain e-spine hip knee 2D knee 3D ventncular Whole Body Whole Soine + T Spine Dot Engine Expand New Find ... Copy Ctrl+C Paste Ctrl+V Delete Rename 5. Select Whole Spine > Whole Spine Dot Engine > Program a. Select Edit Program Icon Dot Cockpit - Explorer Explorer Program Editor Browse Export Import Export x USER > Whole Spine > Whole Spine Dot Engine » program Edit program Dot T-Spine Dot Engine O Spine Standard Lesions Abdomen riumber AASpine Scout stel Brain 3 steps (laser on chin) c-spine 1 AAspine scout 00:19 IAAspine Spine Scout › hip Il AAspine scout 00:19 Il AAspine ee 2D Spine Scout knee 3D Ill_AAspine_scout 00:19 . ventricular Spine Scout > Whole Body 12 Ist sag 02:50 12_tse_sag 3mm O Spine Positioning 2 Whole Spine @ Spine Pos t1 tse dark-fluid sag 03:34 t1 tse sag 3mm Whale Spine Dot Engine O Spine Positioning @ Spine Pos program 12 tse stir sag 3mm O Spine Pos Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/04/2020 | HOOD05162003111621 Healthineers Page 2 of 7 Job Aid | Dot Cockpit –Build Whole Spine Dot Engine – Eline & Numaris X Effective Date: 08/04/2020 | HOOD05162003111621 6. Add Cervical and Lumbar Spine Sequences a. Select Browse > Siemens Tree > c-spine > C-Spine Dot Engine > Program i. Select Click to Open Full View Dot Cockpit - Program Editor (Program Path = USER/Whole Spine/Whole Spine Dot Engine/program) Explorer Program Editor Edit Simulate X ». Standard Browse Search Default USER >> Whole Spine >> Whole Spine Dot Engine > program SIEMENS Dat T-Spine Dot Engine O Spine Patie Standard Lesions number AASpine Scout steps > head 3 steps (laser on chin) c-spine _AAspine_scout 00:19 _AAspine_sco O Spine Scout C. Spine Dot Engine Il AAspine scout 00:19 Il AAspine so O Spine Scout clinical libranes III AAspine_scout 00:19 library Spine Scout localizer 12 tsc sag 02:50 12_tse_sag_3mm 04 O Spine Positioning 2 O Spine Positioni t1 tse dark-fluid sag 03:34 11_tse_sag_3mm 04 O Spine Positioning O Spine Positioni PD 12 tse stir sag 3mm 04 30 O Spine Positioni diffusion AutoAlign Verification AutoAlign Verification O Spine Verification O Spine Verificati QUIET 12-tra options 12 tse tra 04 WARP without t2-tra options Basic Decision Spine Positioni HeadNeck64 12-tra options t1 tse tra 04 L-spine with 12-tra options without 12-tra options Spine Positioni › I-spine 12 space tra 05:08 12 tse tra 04:07 O Spine Positioning O Spine Positioning contrast agent with contrast agent Basic Decisi contrast agenl with contrast agent inject contrast agent @ Click to open full view t1_tse tra 04:32 Spine Positioning Strategy Decision t1 tse sag 3mm 04:32 Interaction Pause b. Select T2 Sag Sequence (C-Spine) i. Left Mouse > Drag Sequence to ... >> C-Spine Dot Engine >> program Standard Strategy ii. Select t2_tse_sag sequence > Right V Standard Mouse > Rename t2_tse_sag_C-Spine AAspine_scout 12_tse_sag 11 tse dark-tund sag 1 AutoAlign Verification 12-tra options 1 vitriout 12-tra optionsY 12 tra Antions Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/04/2020 | HOOD05162003111621 Healthineers Page 3 of 7 Job Aid | Dot Cockpit –Build Whole Spine Dot Engine – Eline & Numaris X Effective Date: 08/04/2020 | HOOD05162003111621 c. Select Browse > Siemens Tree > l-spine > L-Spine Dot Engine > Program i. Select Click to Open Full View ii. Select T2 Sag Sequence 1. Left Mouse > Drag Sequence to Standard Strategy 2. Select t2_tse_sag sequence > Right Mouse > Rename t2_tse_sag_L-Spine iii. Select t2_tse_sag sequence > Right Mouse > Rename t2_tse_sag_T-Spine Dot Cockpit - Program Editor (Program Path = USER/Whole Spine/Whole Spine Dot Engine/pros Explorer Program Editor Edit Simulate USER > Whole Spine >> Whole Spine Dot Engine >> program V Standard 3 steps (laser on chin) I_AAspine_scout Il AAspine_scout III_AAspine_scout 12_tse_sag_C-Spine 03.11 Spine Positioning t2_tse_sag_T-Spine 02:50 Spine Positioning t1 tse_dark-fluid_sag - T-Spine 03:34 LO Snine Positioning 12_tse_sag_L-Spine 03:46 Spine Positioning 7. Repeat Steps to add additional sequences to Whole Spine Dot Engine Protocol a. TIRM Sag, T1 Sag, T2 Tra, etc. Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/04/2020 | HOOD05162003111621 Healthineers Page 4 of 7 Job Aid | Dot Cockpit –Build Whole Spine Dot Engine – Eline & Numaris X Effective Date: 08/04/2020 | HOOD05162003111621 Dot Cockpit - Program Editor (Program Path = USER/Whole Spine/Whole Spine Dot Engine/program) Explorer Program Editor Edit Simulate x USER » Whole Spine > Whole Spine Dot Engine >> program Dot 8. Add Copy Reference to Sequences Standart a. Ctrl + Left Mouse > select Reference 3 steps (laser on chin) and Target Series 1 AAspine scout b. Right Mouse > select Create Copy Il AAspine scout Reference III AAspine scout 12_tse_sag_C-Spine 03.11 Spine Positioning t2 tse sag T-Spine 02:50 t2 tse_s Spine Positioning +1_tse_dark fluid_sag - T-Spine 03-34 Copy Ctrl+C 12_tse_sag_L-Spine Paste Ctrl+V Delete Rename Check License AutoAlign Verification Convert Expand t2-tra options Collapse without 12-tra options 12-tra options Show Protocol History with 12-tra options Compare Protocols: t2 space tra 05:08 12 tse tra Create Copy Reference Spine Positioning View Properties. Edit Properties .. c. Check box Copy reference is active i. Copy Parameter Group > select an Option from list ii. Select OK USER >> Whole Spine >> Whole Spine Dot Engine >> program > t1 tse dark fluid sag - T-Spine General Protocol Parameters Copy reference is active Voice Commands : Source protocol step (2_Ise_sag_ Spine Execution Image Management Copy parameter group Center of slice groups and saturation regionis Auto Load Slices and saturation regions Slices and Adjustment volume Copy References Slices Preview Saturation regions Measurement parameters Adjustment volume Table position Navigators Everything Copy phase encoding direction Steps J'ignore measurements Ignore last step Addin Configuration Cancel 58 9 Identical [] Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/04/2020 | HOOD05162003111621 Healthineers Page 5 of 7 Job Aid | Dot Cockpit –Build Whole Spine Dot Engine – Eline & Numaris X Effective Date: 08/04/2020 | HOOD05162003111621 9. Select Save Program Icon Dot Cockpit - Program Editor (Program Path = USER/Whole Spine/Whole Spine Dot Engine/pro Explorer Program Editor Edit Simulate USER >> Whole Spine > Whole Spine Dot Engine > program Standard 3 steps (laser on chin) I_AAspine_scout 10. Select Program Editor > Simulate a. Review Whole Spine Program Created i. Make additional edits as needed Dot Cockpit - Program Editor (Program Path = USER/Whole Spine/Whole Spine Dot Engine/pro Explorer Program Edter Edit Simulale USER > Whole Spine >> Whole Spine Dot Engine >> program Standard 3 steps (laser on chin] IAAspine scout Il_AAspine_scout III AAspine_scout t2_tse sag_C-Spine 03:11 O Spine Positioning 12 tse san T-Spine 02:50 O Spine Positioning t1 tse dark-fluid sag -T-Spine 03:34 O Spine Positioning 12_tse_sag_L-Spine 03.46 Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/04/2020 | HOOD05162003111621 Healthineers Page 6 of 7 Job Aid | Dot Cockpit –Build Whole Spine Dot Engine – Eline & Numaris X Effective Date: 08/04/2020 | HOOD05162003111621 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 08/04/2020 | HOOD05162003111621 Healthineers Page 7 of 7
- Dot
- Cockpit
- Build
- Whole Spine
- Dot Engine
- Eline
- Numaris X