Dot Cockpit and MR Protocol Module - Mass Protocol Editing - XA31
This Job Aid discusses how to edit mass protocols using the Dot Cockpit and MR Protocol Module for XA31 MR Systems.
Dot Cockpit and MR Protocols Module - Mass Protocol Editing - XA31 Job Aid 1. How can the Mass Protocol Editing support you within the Dot Cockpit/MR Protocols Module? Parameters on the parameter card and the properties are accessible. Several parameter changes can be performed in one procedure step. History of changes is listed in an overview. Please note: Graphical slice objects, such as slice groups, saturation regions and set’n’go steps cannot be edited in the Find dialog. 2. How can you use it? 1. Open the Dot Cockpit and select the region, exam, or program in the Siemens tree. Dot Cockpit - Explorer Explorer Program Editor Browse Import Export Edit Simulate USER cine trufi frequency scout cine flash heart tagging › Cardiac Dot Engine localizer morholony function cine trufi cine flash tagging Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 8-Mar-21 I HOOD05162003171361 Healthineers US Job Aid Effective Date: 4.20.2021 I HOOD05162003184915 Job Aid I Dot Cockpit and MR Protocols Module - Mass Protocol Editing Effective Date: Error! Reference source not found. I HOOD05162003184915 US Effective Date: Error! Reference source not found. I HOOD05162003184915 2. Right-mouse click on the program and select Find… to open the Find Dialog. USER USER >> heart »> function >> cine trufi retrospective gating cine_trufi_retro 00:14 heart > Cardiac Dot Engine cine_trufi_retro_reduced_fov 00:20 >localizer > morphology cine_trufi_retro_arryth 00:28 function cine_trufi_retro_cs_2_shot 00:02 cine trufi Edit ... cine_trufi_retro_cs_8_shot 00:08 New Find _ventricular volume ta Copy Ctrl+- dy tiss Ctrl+V cine_trufi_retro_10sl_invf 02:15 Paste 3. With the search function Name, the displayed results can be narrowed down. Select the protocols, that you want to change. The first selected protocol is the master protocol. This means the parameters for the protocol is shown later. Editing is started by clicking on the Edit selected button. Find and Set Parameters X ne Q cine Location Selected Element Type All Step Types Path Name USER/heart/function/cine trufi cine_trufi_retro USER/heart/function/cine trufi cine_trufi_retro_arryth USER/heart/function/cine trufi cine_trufi_radial_retro USER/heart/function/cine trufi cine_trufi_prosp USER/heart/function/cine trufi cine_trufi_prosp_5sl USER/heart/function/cine trufi cine_trufi_retro_BS USER/heart/function/cine trufi cine_trufi_retro_reduced_fov USER/heart/function/cine trufi cine trufi retro 10sl invf USER/heart/function/cine trufi cine_trufi_rt_10sl_trig USER/heart/function/cine trufi cine_trufi_prosp_reduced_fov USER/heart/function/cine trufi cine trufi retro_cs_2_shot Select all Unselect all Edit selected Cancel SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: I HOOD05162003184915 US Job Aid Effective Date: 4.20.2021 I HOOD05162003184915 Job Aid I Dot Cockpit and MR Protocols Module - Mass Protocol Editing Effective Date: Error! Reference source not found. I HOOD05162003184915 US Effective Date: Error! Reference source not found. I HOOD05162003184915 4. Edit the required parameters and select Accept changes. These changes apply to the other selected protocols. Find and Set Parameters Protocol Parameters Routine Contrast Resolution Geometry System Physio Inline Sequence Voice Commands Execution Slice Group FoV Read 360 mm Image Management Slices 1 ¢ FoV Phase 81.3 % Auto Load Slice Thickness 6.0 mm Service Distance Factor 20 - 9 TR 42.0 ms Position L17.1 A1.0 H0.0 TE 1.54 + ms Orientation T> C27.7 > 5-1.8 Averages Phase Encoding Dir. A>> P Concatenations Phase Oversampling Auto Align ... Slice Thickness 6.0 3.0- 200.0 mm Accept Changes Cancel 5. The History of Changes on the right side of the window tracks all changes made on the ? × master protocol. If the same parameter is sio Inline Sequence History of Changes changed repeatedly, the changes are chronically lead 360 mm Flip Angle 90 deg kept, since parameter changes may create 81.3 % Wrap-up Magn. None ase 1st Signal/Mode Beat Sensor/Retro dependencies on other parameters. less 6.0 ¢ mm Slice Thickness 8.0 mm TR 42.0 ¢ ms Slice Thickness 6.0 mm TE 1.54 + ms Change voice commands Use local settings Voice Commands Automatic ges Before Scan Hold breath (inhaled). ons After Scan Continue breathing. Pause Os ign 200.0 mm ancel Please note: If modifications cannot be executed e.g. due to non-availability of parameters, unmodified protocols are listed in an unmodified Protocols window. This means none of the parameter adaptations were done on these protocols. SIEMENS Unrestricted Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: I HOOD05162003184915 US Job Aid Effective Date: 4.20.2021 I HOOD05162003184915 Job Aid I Dot Cockpit and MR Protocols Module - Mass Protocol Editing Effective Date: Error! Reference source not found. I HOOD05162003184915 US Effective Date: Error! Reference source not found. I HOOD05162003184915 Please note that this learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2021 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com SIEMENS Healthineers
- MR
- Protocol
- Module
- Dot Cockpit
- XA31
- Editing