DTI Evaluation Neuro 3D (A-E Line)

DTI Evaluation Neuro 3D (A-E Line)

DTI Evaluation - Neuro 3D (MR) A to E-line DTI Evaluation allows for quantitative evaluation of the rate and direction of water mo- tion within a voxel, calculation of different diffusion parameters, and graphic displays of colored DTI maps. applications Transfer 1. From the Patient Bowser > select Tensor series Report Open a. Select Applications > Neuro 3D (MR), and load a Tensor data Report Tools set into Neuro 3D (MR) Task Card Mosaic (or) 3D b. Neuro 3D (MR) Icon Argus BOLD BOLD Evaluation Soft Tissue (MR) c. Data automatically loads into the Neuro 3D (MR) Task Card > Composing Diffusion Mode Mean Curve Perfusion (MR) Spectroscopy Neuro 3D (MR) Tissue 4D (MR) 2. Neuro 3D (MR) Task Card WORKFLOW_ADV_NEURO_1 ARH WORKFLOW_ADY_NEURO_1 a. Diffusion Mode > Viewing Layout 0000000 OID: 0000000 0000000 *3/4/1981 OD: 0000000 *3/4/1981 STUDY 70554.0 STUDY 70554.0 Manipulated, MPR Manipulated, MPR 34 IMA 23 / 37 34 IMA 23 / 37 1) FA Map – Upper Left RPH RPH 2) ADC Map – Upper Right 3) Trace-weighted Map – Lower Left 4) Anatomical b0 Map – Lower Right ADC bo [60,3473)FA [O .- ] bo [60,3473] Anst OFF/FM OFF/Clus OFF W.10009, 22 .......................... Anat OFF/FM OFF/Clus OFF W 2000 C 1093 WORKFLOW_ADV_NEURO_1 ARH WORKFLOW_ADV_NEURO_1 ARH 0000000 OID: 0000000 0000000 ^3/4/1981 OID: 0000000 *3/4/1981 STUDY 70554.0 STUDY 70554.0 Manipulated, MPR 34 IMA 23 /32 RPH RPH TWOCOFFIFM OFFICIUS OFF W 338 C 176 And OFFIFM OFFICUS OFF W 321 C 151 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 SIEMENS Master Template: EFF Date 22 Aug 17 | HOOD/HILS HOOD05162002647849 Healthineers Jobaid: Effective Date: 02/18/2020 | HOOD05162003063685 Job Aid | DTI Evaluation Neuro 3D (MR) A-Eline Effective Date: 02/18/2020 | HOOD05162003063685 3. Visualize DTI Maps a. Select an image segment to display a new diffusion map i. Select Diffusion Tab > Diffusion Map Icons available (e.g.e, icons listed from left to right) ii. Select a Map Icon Orien ... Display Diffus  b0  ADC ADC TraceW  TraceW  FA FA Tensor  Tensor  Anatomy Texture  Diffusion Properties  Texture iii. Dog Ears – scroll through images (maps) created WORKFLOW_ADV_NEURO_1 0000000 WORKFLOW_ADV_NEURO_1 ARH OID: 0000000 0000000 3/4/1981 OID: 0000000 STUDY 70554.0 #3/4/1981 Manipulated, 3D STUDY 70554.0 Manipulated, MPR 34 IMA 22 / 37 34 IMA 22 / 37 RPH Tensor 60.3473/FA [300 ,- /Br. VWt. FA FA-Texture Diffusion Texture OFF/FM OFFICIus OFF FAW 1024 Caja:: b0 [60,3473VFA [0 ,- ] Anat OFF/FM OFF/Clus OFF W 1006 C 359 Diffusion View VISI b. Additional Diffusion Maps (e.g., Reference: Operator Manual bo Neuro for additional information) ADC TraceW i. Select an optional Diffusion Map Exp EA  FA – Fractional Aniostropy RA RA – Relative Aniotropy VR  GA  VR – Volume Ratio Linear Planar  GA – Geodesic Anisotropy Spherical Mode  Linear Map E1  Planar Map E3  Spherical Map E1-E3 E1-E2  Mode Map E2-E3  E1, E2, E3, etc – Eigen Vector Maps Tensor Graphic Texture Diffusion Anatomy Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 2 of 4 Job Aid | DTI Evaluation Neuro 3D (MR) A-Eline Effective Date: 02/18/2020 | HOOD05162003063685 c. Save Diffusion Maps (e.g., exception of Tensor Patient Applications Volumes Inline Mo Maps) Register ... Num 0 i. Select images segment with new map Browser ... Num Close Patient created Save Ctrl+S ii. Select Patient > Save Diffusion Save As. Save Diffusion  Note – Tensor data cannot be Save Diffusion Tractography stored using Save Diffusion. Filming Layout. Film Task Status .. Copy to Film Sheet Num Enter Film Preview ... d. Save Tensor Maps Expose Film Task Ctrl+P i. Select images segment with new Tensor Map created ii. Select Patient > Save As  Note: saves one Tensor Map, repeat to save additional tensor maps Patient Applications Volumes Inline Mo Save As X Register Num 0 Patient WORKFLOW ADV_NEURO_1 Browser Num Modality MR Close Patient Exam date 20080410 Images 1 Save Ctrl+S Save As Selected Segment . All Segments Save Diffusion File System Path C:\Medcom\temp\CDR_OFF Save Diffusion Tractography Export without Filename WORKFLOW ADV NEURO_1 image text Format Bitmap ( *. bmp Filming Layout ... · Database Bitmap (" bmp) Film Task Status ... >Save image(s) in new series Tensor | Copy to Film Sheet Num Enter Append image(s) to series <3D Collection> Film Preview ... Expose Film Task Ctrl+P OK Cancel Help e. Select Diffusion Properties Icon Orien ... Display Diffus. i. Select Interpolation Checkbox – improves image appearance b0 ADC TraceW  Select Close ii. Select Direction Encoded Color > Tensor Globe FA  Tensor Globe shows the direcion of water Tensor and color assigned to fiber tracks Diffusion Properties Texture X Direction Encoded Color x Diffusion Data Type FA Diffusion Map Color Interpolation · Grayscale · Direction Encoded Color b Facton 1000 Close Default More >> Help Close Help Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 3 of 4 Job Aid | DTI Evaluation Neuro 3D (MR) A-Eline Effective Date: 02/18/2020 | HOOD05162003063685 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (herein- after collectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2018 ………………………………………………………… Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2018 Page 4 of 4