Dual Volume Viewing - Exam Room (VD1xx - VD2xx)
Job aid describing steps to view 3D dataset as a dual volume from the examination room.
Dual Volume Viewing - Exam Room (VD1xx-VD2xx) Job Aid Advanced Therapies - Application Software VD1xx to VD2xx. **There is an additional job aid available on PEPconnect to determine SW version of the system. Dual Volumes are used to display and manipulate the Mask and Sub images independently; for example: bones, stents, clips or coils in a different color from the vessels. A DSA or DSA DCT spin is required to be able to visualize as a Dual Volume. A DR or DCT spin CANNOT be used as it only reconstructs a single volume. **Pre-requisitie: ALL three types of reconstructions are required to be in the Local Database – Sub, Nat Mask, and Nat Fill. If all three are NOT in Local Database, this will not work. User can create secondary reconstructions of the missing reconstructions. [3] 3D Body Nat Fill Full HU Auto [AX3D] [3] 3D Body Sub Full EE Auto [AX3D] /com/ //// / [3] 4sDSA Body /com/ /// / / [3] 3D Body Nat Mask Full HU Auto [AX3D] Examples of a Dual Volume: SIEMENS Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Healthineers Job Aid Effective Date: 07/07/2020 | HOOD05162003101318 Job Aid | Dual Volume Viewing – Exam Room Effective Date: 07/07/2020 | HOOD05162003101318 1. Perform any DSA or DSA DCT spin. Images will automatically display on the 4D monitor in exam room. 2. From the joystick module (non-pheno), select the bottom button to open up the Layout Gallery (3) on-screen menu. Scroll through menus, using joystick, until DSA layout is dis- played in the syngo 4D Layouts – Review section, then left click to apply. Review and Processing Viewing Overlay syngo 4D Layouts - Review (1) ded or lumes. ions will isting MPR + VRT 2 VRT VRT + MPR D) (2) syngo 4D Layouts - Compare syngo 4D Volume Presets (3) Rotate Image Windowing QuickZoom Menu Display Layouts syngo 4D Layouts - Review MPR + VRT 2 VRT VRT + MPR 2 VRT + MPR DSA syngo 4D Layouts - Compare syngo 4D Volume Presets F Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/07/2020 | HOOD05162003101318 Healthineers Page 2 of 7 Job Aid | Dual Volume Viewing – Exam Room Effective Date: 07/07/2020 | HOOD05162003101318 3. Pheno – From the pilot module, select the Large Display Layout icon. This icon will open up the on-screen menus to be able to choose syngo 4D Layouts – Review. The jog wheel will be used to scroll up and down or left and right through the menus. OK Jog Wheel Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/07/2020 | HOOD05162003101318 Healthineers Page 3 of 7 Job Aid | Dual Volume Viewing – Exam Room Effective Date: 07/07/2020 | HOOD05162003101318 4. The Nat Mask will automatically load with the Sub image in the VRT segment and the Nat Fill images will automatically load into the remaining three MPR seg- ments. Review and Processing Viewing Overlay on il FILL = NAT FILL FILL = NAT FILL View 3D DSA acquisitions in a fused layout FILL = NAT FILL FUSED = NAT MASK + VRT Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/07/2020 | HOOD05162003101318 Healthineers Page 4 of 7 Job Aid | Dual Volume Viewing – Exam Room Effective Date: 07/07/2020 | HOOD05162003101318 5. To select a different visualization preset, again select the Layout Gallery button (non- pheno) and scroll down to syngo 4D Volume Presets. The first 20 presets from the Favor- ites Type filter will be displayed. Using the joystick, scroll left or right to view available presets. Left click to select and apply. syngo 4D Layouts - Compare syngo 4D Volume Presets (1) (2) (3) DualVolume 20 0DualVolume2 20. 6. Pheno - From the pilot module, select the Large Display Layout icon. This icon will open up the on-screen menus to be able to choose syngo 4D Volume Presets. The jog wheel will be used to scroll up and down or left and right through the menus. OK Jog Wheel X Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/07/2020 | HOOD05162003101318 Healthineers Page 5 of 7 Job Aid | Dual Volume Viewing – Exam Room Effective Date: 07/07/2020 | HOOD05162003101318 7. The selected visualization preset will be applied to either the VRT or the MPRs depending on what segment is selected. To apply a preset to other segment(s), choose that type of segment (VRT or MPR) and repeat step 4. 8. There is NO access to the Dual Volume Properties box at tableside; it is only available from the control room. Dual Volume Properties ? X 1. thin ne pas envoyer sur PACS ... 2. AAA ABDO-PELV C+ 10/22/2 ... Fusion Method Addition (1 + 2) Swap order 2 Close Help Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/07/2020 | HOOD05162003101318 Healthineers Page 6 of 7 Job Aid | Dual Volume Viewing – Exam Room Effective Date: 07/07/2020 | HOOD05162003101318 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter co llectively “Operator Manual”) issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively “Functionality”) may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written auth ority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright © Siemens Healthcare GmbH 2020 Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Phone: +49 9131 84-0 siemens-healthineers.com Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 07/07/2020 | HOOD05162003101318 Healthineers Page 7 of 7
- Dual Volume Viewing - Exam Room (VD1xx - VD2xx)