Dual Volume Viewing - Control Room (VD1xx-VD2xx)
Dual Volume Viewing - Control Room (VD1xx-VD2xx) Job Aid
Dual Volume Viewing - Control Room (VD1xx-VD2xx) Job Aid Advanced Therapies - Application Software VD1xx to VD2xx. **There is an additional job aid available on PEPconnect to determine SW version of the system. Dual Volumes are used to display and manipulate the Mask and Sub images independently; for example: bones, stents, clips or coils in a different color from the vessels. A DSA or DSA DCT spin is required to be able to visualize as a Dual Volume. A DR or DCT spin CANNOT be used as it only reconstructs a single volume. **Pre-requisitie: ALL three types of reconstructions are required to be in the Local Database – Sub, Nat Mask, and Nat Fill. If all three are NOT in Local Database, this will not work. User can create secondary reconstructions of the missing reconstructions. [3] 3D Body Nat Fill Full HU Auto [AX3D] [3] 3D Body Sub Full EE Auto [AX3D] /com///// / [3] 4sDSA Body /com///// / [3] 3D Body Nat Mask Full HU Auto [AX3D] Examples of a Dual Volume: Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: XX/XX/XXXX | HOOD/HILS Healthineers Job Aid | Dual Volume Viewing – Control Room Effective Date: 05/29/2020 | HOOD05162003096961 1. Perform any DSA or DSA DCT spin. Images will automatically transfer to the 4D taskcard in control room. Previously performed DSA or DSA DCTs can also be loaded into 4D taskcard. 2. Click on the Layouts icon. Review and Processing Viewing Review volumes loaded from the patient browser 3. Select the DSA layout under Review section. Review and Processing Review Viewing ? H Select a thumbnail to activate the appropriate layout Review MPR + VRT 2 VRT MPR + VRT 2 VRT VRT + MPR 2 VRT + MPR VRT + MPR 2 VRT + MPR Overlay DSA Unrestricted 0 Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/29/2020 | HOOD05162003096961 Healthineers Page 2 of 6 Job Aid | Dual Volume Viewing – Control Room Effective Date: 05/29/2020 | HOOD05162003096961 4. The Nat Mask will automatically load with the Sub image in the VRT segment and the Nat Fill images will automatically load into the remaining three MPR seg- ments. AXIOM-Artis 20.05.26-06:39:00-STD -. VE108 200116 3D Body Nat Fill Full HU. VÉ 108 200118 HFS 1/1/1900 XA 5/26/2020 7:39:59 AM SL 0.5 MIP Thin LAO 90 / 0 FEE 20.05.26-06:39:00-STD 20.05.26-06:39:00-STD- TDC Cary 20.05.26-06:39:00-STD 3D Body Nat Fill Full HU. AXIOM-Arts 20.05.26-06:39:00-STD -... AXIOM Ad VE 108 200116 3D Body Sub Full EE Au .. JE 108 200116 1/1/1900 HFS ¥1/1/1900 XA 5/26/2020 5/26/2020 7:39:59 AM 7:39:59 AM 3D Body Nat Mask Full, 3D DSA 0/0 32:
- Dual Volume Viewing
- Control Room
- VD1xx-VD2xx