Dynavision
Dynavision Interventional Radiography: Cardiac Please refer to manual for complete system capability at www.siemenslearningcenter.com 1. Isocenter your patient Fluoro and center patient in the frontal projection Move c-arm to 90 degrees and center patient in the lateral projection 2. Select your first angle *Though this angle is first selected, it will be your end angle 3. Select appropriate Dynavision program 4. Fluoro 5. Rotate c-arm to your second angle *Though this is the second angle selected, it will be your start angle 6. Fluoro **** Dynavision is ready to go **** Select x-ray delay, select injection rates, etc. and arm injector Start acquisition using handswitch or foot pedal DR- Dynavision System will remain in position until x-ray delay has been counted down and then rotate through the arc that was set. DSA Dynavision C-arm will rotate through arc selected for its mask run, it will return to the start position/angle (Remember: this is the second angle that was selected) It will stop at that angle and count down the x-ray delay that was set. When that delay is completed, the c-arm will rotate thought the arc again acquiring your subtracted rotational image. ** X-ray delay hints: Catheter to target distance Cardiac output Pathology ** Spin time + x-ray delay = total injection duration ** Flow rate (ml) x total injection duration (sec) = total volume to be injected SIEMENS siemens.com/healthineers Healthineers . Job Aid | Dynavision Effective Date: 09/06/2016 | Quality HOOD0516200893808 Please note that the learning material is for training purposes only! For the proper use of the software or hardware, please always use the Operator Manual or Instructions for Use (hereinafter collectively "Operator Manual") issued by Siemens Healthineers. This material is to be used as training material only and shall by no means substitute the Operator Manual. Any material used in this training will not be updated on a regular basis and does not necessarily reflect the latest version of the software and hardware available at the time of the training. The Operator's Manual shall be used as your main reference, in particular for relevant safety information like warnings and cautions. Note: Some functions shown in this material are optional and might not be part of your system. Certain products, product related claims or functionalities (hereinafter collectively "Functionality") may not (yet) be commercially available in your country. Due to regulatory requirements, the future availability of said Functionalities in any specific country is not guaranteed. Please contact your local Siemens Healthineers sales representative for the most current information. The reproduction, transmission or distribution of this training or its contents is not permitted without express written authority. Offenders will be liable for damages. All names and data of patients, parameters and configuration dependent designations are fictional and examples only. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Copyright @ Siemens Healthcare GmbH ...... ........... Siemens Healthineers Headquarters Siemens Healthcare GmbH Henkestr. 127 91052 Erlangen, Germany Telephone: +49 9131 84-0 siemens.com/healthineers Siemens Healthineers Services Page 2 of 2
- Artis Q
- Artis zee
- Artis Zen