Efficient Scanner Usage with eMode
This Step-by Step will instruct the user how to operate the scanner in the most patient-friendly and financially-efficient way using eMode. Consistent use of eMode relieves the system of unnecessary wear and increases the scanner’s life cycle.
Efficient Scanner Usage with eMode Biograph Horizon This Step-by Step will instruct the user how to operate the scanner in the most patient- friendly and financially-efficient way using eMode. Consistent use of eMode relieves the system of unnecessary wear and increases the scanner’s life cycle. What is eMode? eMode is a unique software solution that automates efficient use of CT scanner with - no appreciable loss in image quality. When the user prepares a scan protocol, eMode analyzes the scan in real time and the instantly fine-tunes parameters to provide the ex- act scan you want, while simultaneously reducing wear and tear on the system. Possible Scenarios: Scenario 1 e Load eMode indicator is green. This means that the scan protocol shows no - conflict AND the average power required is below 20kW. Click Load and proceed with scan. Scenario 2 e Adjust Load eMode indicator is yellow. This means that the scan protocol shows - no conflict BUT the average power required is above 20kW. Click Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date: 05/19/2020 | HOOD/HILS HOOD05162003089270 Healthineers Job Aid | Efficient Scanner Usage with eMode Effective Date: 05/19/2020 | HOOD/HILS HOOD05162003089270 Adjust and scan parameters will be modified resulting in an eMode scan. *Note that eMode scan is acheived by adjusting scan time and reducing max mAs without visible loss of IQ. The system always starts with the adjustment of the scan time and if necessary will then cut a up to 25% of the max mAs. (Limits can be set in Scan Protocol Assistant) Scenario 3 e Adjust Load eMode indicator is green and Load has yellow ring. This means there - is a cooling or CareDose4D conflict with current setting. Click Adjust and scan parameters will be modified to rectify CareDose4D conflict AND achieve an eMode scan. After selecting Adjust, buttons will have this appearance: ℮ Adjust Load Click Load to proceed with eMode scan. Scenario 4 Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date:05/19/2020| HOOD/HILS HOOD05162003089270 Healthineers Page 2 of 3 Job Aid | Efficient Scanner Usage with eMode Effective Date: 05/19/2020 | HOOD/HILS HOOD05162003089270 Load eMode indicator is gray. This means the selected entry cannot be - scanned in eMode. Adjust will not appear because the scan time to achieve eMode would exceed the configured max. Active/Deactive Left mouse click on the e to toggle between Green (active mode): e and Blue (eMode deactivated): Unrestricted | Published by Siemens Healthcare GmbH © Siemens Healthcare GmbH, 2020 SIEMENS Master Template Effective Date: 3/5/2020 | HOOD05162003074494 Job Aid Effective Date:05/19/2020| HOOD/HILS HOOD05162003089270 Healthineers Page 3 of 3
- eMode